| Plan Review Stops For Permit 03100025 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-10-06 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-01-07 |
Time |
11:43 |
Sent To |
PC |
|
| Notes |
| 2004-09-24 00:00:00 | REVISION CHECKLIST: | | | 1-ARCHITECT SUBMITTING REVISION IS NOT | | | THE SAME ARCHITECT OF RECORD.ARCHITECT | | | NEEDS TO FOLLOW RULE 61G1-18.002 OF FL | | | ADMINISTRATIVE CODE WHEN TAKING OVER | | | ANOTHER ARCHITECT'S WORK. | | | 2-ENGINEER'S REPORT: A)PROVIDE 2 COPIES | | | WITH ORIGINAL SEAL, SIGNATURE & DATE | | | AS REQ'D BY CHAPTER 471 FL STATUTES. | | | B)ENGINEER TO PROVIDE ALL INFORMATION | | | AS REQUIRED BY SEC. 1606.1.7 FBC 2001. | | | 3-ARCHITECT AND ENGINEERTO HAVE | | | TITLE BLOCK WITH ALL INFORMATION AS | | | REQUIRED BY CHAPTER 481 AND 471 OF | | | FLORIDA STATUTES. INCLUDING THE | | | CERTIFICATE OF AUTHORIZATION. | | | 4-PROVIDE COMPLETE INFORMATION ON WALL | | | SECTIONS:FASTENER TYPE & SPACING | | | FOR STUCCO METAL LATH, WALL AND ROOF | | | SHEATHING, 2X4 REINFORCING FRAMING, | | | FRAMING ANCHOR, ANCHOR TO TOP CHORD | | | ETC. | | | SEC. 104.2.1.2, TABLE 2306.1 OF CITY | | | AMENDMENTS TO FBC 2001. | | | 5-DRAWINGS TO PROVIDE ALL INFORMATION | | | AS REQUIRED BY SEC. 1606.1.7 FBC 2001. | | | 6-ROOF FRAMING LAYOUT ON MAIN ROOF WAS | | | CHANGED FROM ORIGINAL DWGS. SPECIFY | | | ROOF TRUSS CONNECTORS FOR MODIFIED | | | TRUSSES. SEC. 104.2.1.2 CITY AMENDMENT | | | 7-CLARIFY WHY IS THE TRUSS MANUFACTURER | | | RESPONSIBLE TO VERIFY IF EXISTING | | | TRUSSES WILL TAKE THE ADDITIONAL LOAD. | | | THE DESIGNER IS THE ONE WHO VERIFIES | | | THAT EXISTING STRUCTURE WILL BE ABLE | | | TO SUPPORT THE ADDITIONAL LOAD OR | | | REINFORCE IT AS REQUIRED. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC. | | | 8-PROVIDE CERTIFICATE OF AUTHORIZATION | | | FOR THE ENGINEERING AND ARCHITECTURAL | | | BUSINESS AS REQUIRED BY CHAPTER 471 | | | AND 481 FLORIDA STATUTES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
15:20 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-03-04 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
| 2004-03-04 00:00:00 | BUILDING REVIEW PROVISO: | | | 1-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL UNDER A SEPARATE PERMIT (NO | | | FEES, AS PER NEIL MELICK) FOR: | | | A)FIXED WINDOWS WITH SIZE AS SHOWN ON | | | PLANS AT LIVING AND BREAKFAST AREAS. | | | B)GARAGE DOORS WITH DRAWINGS SHOWING | | | MODELS TO BE USED. | | | | | | 2-PROVIDE COMPLETE & LEGIBLE INFORMATION | | | FOR FIREPLACE. UL LISTING AND COMPLETE | | | INTALLATION SPECS. | | | 3-REVISE ROOF PLANS, EXTERIOR ELEVATIONS | | | AND CHIMNEY FRAMING DETAILS/SECTION | | | AND PLAN TO MATCH ACTUAL LOCATION OF | | | CHIMNEY. SEE FLOOR PLAN FOR EXACT | | | LOCATION. SECTION 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-04 |
Time |
14:42 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2004-02-09 |
Time |
17:52 |
Sent To |
PC |
|
| Notes |
| 2004-02-09 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-PROVIDE FLORIDA PRODUCT APPROVAL OR | | | COMPLETE SITE SPECIFIC PRODUCT APPRO- | | | VAL FOR ALL DOOR AND WINDOW TYPES (SEE | | | PLANS FOR SIZES AND ASSEMBLIES SHOWN), | | | ROOF TILE, MULLIONS AND ALL STRUCTURAL | | | CONNECTORS. | | | 2-ARCHITECT TO PROVIDE ALL INFO. REQ'D | | | BY CHAPTER 481 FLORIDA STATUTES WHEN | | | SUBMITTING DWGS FOR PUBLIC RECORDS. | | | SEE COMMENTS BY ELECTRICAL & PLUMBING | | | PLAN REVIEWERS. | | | 3-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 4-ARCHITECT TO PROVIDE ALL INFORMATION | | | AS REQUIRED AND LISTED ON SECTION | | | 1606.1.7 FBC 2001. | | | 5-PROVIDE COMPLETE INSTALLATION SPECS | | | AND LEGIBLE DRAWINGS FOR VENTLESS | | | FIREPLACE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE FEEL | | | FREE TO CONTACT JULIO GOMEZ AT (561) | | | 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-26 |
Time |
16:03 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2004-01-02 |
Time |
09:30 |
Sent To |
PC |
|
| Notes |
| 2004-01-02 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-ARCHITECT NEED CORRECT AND COMPLETE | | | INFORMATION ON TITLE BLOCK AS REQUIRED | | | BY CHAPTER 481 FLORIDA STATUTES WHEN | | | SUBMITTING INFORMATION FOR PUBLIC | | | RECORDS. | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 3-ARCHITECT TO PROVIDE ALL INFORMATION | | | LISTED ON SEC.1606.1.7 FBC 2001. | | | 4-DESIGN PARAMETERS TO INCLUDE THE 30PSF | | | OR 10PSF ATTIC LIVE LOAD AS REQ'D BY | | | TABLE 1604.1 FBC 2001. | | | 5-PROVIDE FLORIDA PRODUCT APPROVAL OR | | | COMPLETE SITE SPECIFIC ENGINEERING FOR | | | ALL DOORS, WINDOWS, MULLIONS, ROOF | | | TILE, TRUSS CONNECTORS, GARAGE DOORS. | | | VISIT WWW.FLORIDABUILDING.ORG FOR | | | INFORMATION REQUIRED TO BE SUBMITTED. | | | **NOTE: CHECK SIZES AND TYPES OF WINDOWS | | | DOORS SHOWN ON PLANS. PRODUCT APPROVAL | | | NEED TO MATCH THEM. THIS INCLUDES | | | SPECIAL WINDOW AT BREAKFAST AREA. | | | 6-PROVIDE UL LISTING AND COMPLETE INFO. | | | FOR FIREPLACE AND BBQ. SEC. 2806 AND | | | 2808 FBC 2001. | | | 7-REVISE TRUSS ANCHOR SCHEDULE TO COMPLY | | | WITH SEC. 1609.4.3 FBC 2001. | | | **NOTE: SPECIFY FASTENER TYPE/NUMBER AS | | | SHOWN ON REVISED CATALOGUE. OTHERWISE, | | | PROVIDE ENGINEERING CALCULATIONS FOR | | | DIFFERENT SPECIFICATIONS. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 8-PROVIDE DETAIL/SPECIFICATIONS FOR | | | CEILING INSTALLATION AT ENTRY PORCH | | | WHEN USING STUCCO. SEE ASTM C-926 AND | | | ASTM C-1063 FOR STUCCO THICKNESS REQ'D | | | AND TYPE,SIZE AND SPACING OF FASTENER | | | REQUIRED. (INFO.SUBMITTED ON SHEET A-6 | | | ANDA-7 IS INCORRECT & NOT COMPLETE) | | | 9-DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENERS AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | 10-DRAWINGS NEED TO BE STAMPED BY THE | | | COUNTY FOR IMPACT FEES. | | | 11-PLEASE CLOUD ALL CORRECTIONS/REVISION | | | DONE TO NEW DRAWINGS TO EXPEDITE THE | | | REVIEW PROCESS. | | | 12-SHEET A-7:A)CLARIFY WHERE ARE DETAILS | | | P AND L SHOWN ON ROOF FRAMING PLAN?. | | | B)MISSING SOME CONNECTION DETAILS. EG: | | | CONNECTIONS FOR COLS AT ENTRY PORCH. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | C)ROOF FRAMING PLAN IS MISSING CHIMNEY | | | LOCATION AND FRAMING AROUND IT. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ @ 805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-12 |
Time |
11:36 |
Rev Time |
4.00 |
| Received By |
jgomez |
Date |
2003-11-17 |
Time |
14:15 |
Sent To |
PC |
|
| Notes |
| 2003-11-17 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-ARCHITECT TO PROVIDE ALL INFORMATION | | | REQ'D BY CHAPTER 481 FLORIDA STATUTES. | | | INCLUDING NAME OF PERSON SIGNING THE | | | PLANS. SEE 61G1-16.004 F.A.C. | | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | | 3-ARCHITECT TO PROVIDE ALL INFORMATION | | | LISTED ON SEC. 1606.1.7 FBC 2001. | | | 4-DESIGN PARAMETERS INFORMATION TO | | | INCLUDE THE ATTIC LIVE LOAD (10PSF OR | | | 30PSF) AS REQUIRED BY TABLE 1604.1 FBC | | | 5-SPECIFY JOINTS IN CONCRETE SLAB AND/OR | | | SPECIFY WWM SUPPORTS AND SPACING IN | | | CONCRETE SLAB. SEE SEC. 1909.3 FBC2001 | | | 6-AS OF OCT. 1ST 2003 CONTRACTOR NEEDS | | | TO PROVIDE FLORIDA PRODUCT APPROVAL OR | | | LOCAL PRODUCT APPROVAL. SEE QUESTIONS | | | & ANSWERS FOR PRODUCT APPROVAL LAW ON | | | WWW.FLORIDABUILDING.ORG FOR PROPER | | | INFORMATION TO BE SUBMITTED. | | | **NOTE:SEE COMMENTS ON PRODUCT APPROVALS | | | SUBMITTED. PROVIDE PRODUCT APPROVAL | | | FOR ACTUAL TYPE OF WINDOWS/DOORS TO BE | | | INSTALLED. | | | **PRODUCT APPROVAL REQ'D FOR: ROOF TILE, | | | SINGLE HUNG WINDOWS, FIXED AND ARCHED | | | WINDOWS (CHECK SIZES ON PLANS), FRENCH | | | DOORS WITH SIDELITES (SEE PLANS), | | | ENTRY DOORS, GARAGE DOORS, MULLIONS. | | | 7-CLARIFY IF USING IMPACT WINDOWS AND | | | DOORS OR PROVIDE COMPLETE INFORMATION | | | FOR STORM SHUTTERS. | | | 8-PROVIDE UL LISTING AND COMPLETE SPECS | | | FOR FIREPLACE AND BBQ. AS REQUIRED BY | | | SEC. 2806 AND 2808 FBC 2001. | | | 9-PROVIDE COMPLETE DETAIL/SECTION AT | | | INSTALLATION OF FIXED WINDOWS TO | | | MULLIONS AT BREAKFAST WINDOW. SPECIFY | | | ALL MATERIALS AND FASTENERS. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 10-REVISE/TRUSS ANCHOR SCHEDULE AND ALL | | | DETAILS THAT ARE AFFECTED BY SECTION | | | 1609.4.3 FBC 2001, WHICH DOESN'T ALLOW | | | THE STEEL STRESS INCREASE TO BE USED. | | | **NOTE: SEE USP 2003 CATALOGUE, WHICH | | | IS ALREADY REVISED.PROVIDE ENGINEERING | | | CALCS FOR CONNECTORS W/ FASTENER TYPE, | | | NUMBER AND VALUES OTHER THAN THOSE | | | PUBLISED ON THE CATALOGUE. ALSO, CHECK | | | CATALOGUE FOR CORRECT DESCRIPTION OF | | | CONNECTORS. | | | 11-PROVIDE STRUCTURAL BUCK DETAIL FOR | | | ENTRY DOORS WHEN REQUIRED BUCK NEEDS | | | TO BE 2X AS REQUIRED BY THE PRODUCT | | | APPROVAL. SAME FOR ARCHED WINDOWS. SEE | | | CORRESPONDING PRODUCT APPROVALS.SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 12-PROVIDE DETAIL/SPECIFICATIONS FOR | | | CEILING INSTALLATION AT ENTRY & REAR | | | PORCH. SPECIFY MATERIALS/FASTENER SIZE | | | SEE ASTM C-926 AND ASTM C-1063. | | | SEC. 2504.2 FBC 2001. | | | 13-SPECIFY ROOF TILE FASTENERS. SEE SEC. | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | 14-LIBRARY ROOM MAY BE USED FOR SLEEPING | | | PURPOSES. PROVIDE EGRESS FROM THIS RM | | | OR ARCHITECT TO CLEARLY WRITE NOTE ON | | | THIS ROOM THAT "THIS ROOM IS NOT TO BE | | | USED FOR SLEEPING PURPOSES" AS REQ'D | | | BY THE BUILDING OFFICIAL AND SECTION | | | 1005.4 FBC 2001. | | | 15-SHEET A-1: REVISE/UPDATE ALL NOTES | | | AS REQUIRED. SEE COMMENTS ON PLANS AND | | | RETURN REVIEWED SET TO EXPEDITE THE | | | REVIEW PROCESS. | | | 16-SHEET A-2: A)SPECIFY COLUMN C-4 SHOWN | | | ON FOUNDATION PLAN. | | | B)UPDATE NOTES. SEE COMMENTS ON PLANS. | | | 17-SHEET A-3: SPECIFY SAFETY GLASS WHERE | | | REQ'D. SEC. 2405.2 FBC 2001. | | | 18-SHEET A-7:CONNECTOR J IS FOR WOOD | | | TO WOOD CONNECTION, BUT IS SPECIFIED | | | FOR MASONRY INSTALLATION. CLARIFY. SEE | | | COMMENTS ON ROOF FRAMING PLAN. | | | 19-SHEET A-8: A)UPDATE NOTES. | | | B)CHIMNEY DETAIL. STUCCO TO BE 7/8" MIN. | | | AS REQ'D BY ASTM C-926. | | | C)CONNECTION DETAIL E IS INCOMPLETE. | | | DOESN'T SPECIFY ANCHORS AND SIZES. | | | ALSO, IS NOT CLEAR WHICH ONE TO BE | | | USED ON ROOF FRAMING PLAN ACCORDING TO | | | SPECIFIC LOCATION. CLARIFY AS REQ'D. | | | D)CLARIFY ONE STORY WALL SECTION. FOOT'G | | | SIZE. NEED 4"MIN. ABOVE GRADE AND 12" | | | MIN. BELOW GRADE. | | | **SPECIFY FIREBLOCKING. SEC. 2305 FBC. | | | **VENTILATION IS FOR ENTIRE ROOF. NOT | | | JUST FOR LIVING AREA. SEC 2309.7 FBC | | | E)SEE COMMENTS ON SHEET A-7 AND RETURN | | | REVIEWED SET TO EXPEDITE REVIEW. | | | | | | NOTE: | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-07 |
Time |
12:03 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-01-07 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2005-01-07 00:00:00 | REDLINED GROUNDING ELECTRODE TO BE 1/0 | | | PER 310.15B6, 250.66 | | | MISSING EQUIPM GRND FROM PANEL "B" TO | | | "C". 250.122 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-20 |
Time |
06:28 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-02-20 |
Time |
06:28 |
Sent To |
P |
|
| Notes |
| 2004-02-20 00:00:00 | ** PANEL "B" SHOWS CONDUCTOR SIZE FOR | | | PANEL "C" AS #6, REDLINED TO SEE RISER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
16:38 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-20 |
Time |
16:43 |
Sent To |
P |
|
| Notes |
| 2004-01-20 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL LICENSE #`S | | | ON TITLE BLOCK. THIS INCLUDES ANY | | | CERTIFICATE OF AUTHORIZATION #'S. | | | PLEASE SEE FS 481.219 SUB-SECTION (2), | | | IF OPERATING UNDER NAME OTHER THAN | | | INDIVIDUAL, A CA# IS REQ'D. TITLE BLOCK | | | REFLECTS STENE ASSOCIATES. | | | PLEASE SEE ATTACHED LICENSE INFORMATION | | | AS PRINTED FROM DBPR. | | | PLEASE ALSO NOTE: IN EFFORT TO CONTACT | | | OFFICE OF ABOVE MENTIONED. PHONE # | | | LISTED ON TITLE BLCOK HAS BEEN DIS- | | | -CONNECTED AND NO LONGER IN SERVICE. | | | PLEASE PROVIDE ALL CORRECT INFORMATION | | | AS REQ`D UNDER FS AND FAC. 61G1-16.004 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-14 |
Time |
13:06 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-12-12 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2003-12-12 00:00:00 | ***************** UNSAT **************** | | | | | | PLEASE SEE THAT THERE ARE NOW SOME NEW | | | COMMENTS DUE TO RISER/PANEL SCHEDULE | | | CHANGING, ALSO SOME COMMENT FROM FIRST | | | REVIEW NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE PLANS, ARCH'S LICENSE | | | # DOES NOT SEEM TOCORRELATE WITH SAID | | | SEAL. PLEASE ALSO PLEASE MAKE SURE ALL | | | SHEETS CONTAIN A CLEAR AND VISABLE | | | IMPRESSION TYPE SEAL. | | | ALL ABOVE PER FS 481.221 AND FAC 61G1-16 | | | .004. | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANELS/SCHEDULES. | | | PANELS ARE NOW SHOWN AS MCB AND RISER | | | INDICATES MLO AND DISC'S.? | | | | | | 3)NOTE: PLEASE SEE THAT AIC RATING(S) | | | ARE NOW SHOWN FOR PANELS AND BREAKERS | | | HOWEVER, NO AIC RATINGS ARE SHOWN FOR | | | MAINS. 110.9/ 215.5 | | | | | | 4)NOTE: PLEASE SEE 210.8 FOR RECEPT | | | REQ'D TO BE SHOWN AS GFI/GFI PROTECTED | | | IN GARAGE. | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52 BEDROOM #3./BRKFAST AREA WALL. | | | | | | 6)NOTE: PLEASE SEE FS 553.80(2)(B). | | | PLEASE SEE ATTACHED COPY AND BE SURE ALL | | | COMMENTS ARE ADDRESSED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
15:21 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-22 |
Time |
06:21 |
Sent To |
M |
|
| Notes |
| 2003-10-22 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004 , | | | PLEASE SEE THAT ALL LICENSE INFORMATION | | | IS REQ'D TO BE ON TITLE BLOCK. PLEASE | | | INCLUDE FIRM'S # ALONG WITH ARCH'S#. | | | PLEASE SEE THAT RAISED SEALED MUST BE | | | CLEARLY VISABLE AND FULLY READABLE. | | | | | | 2)NOTE: PLEASE SIZE SEC'S FOR A 400A | | | SERVICE PER 310.15(B)(6) 400MCM MIN. | | | | | | 3)NOTE: PLEASE INCLUDE BLDG FOOTER | | | STEEL AS PART OF THE GROUNDING ELECTRODE | | | SYSTEM AS REQ'D IN 250.50 | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL SERVICE EQUIPMENT. MAINS, PANELS AND | | | BREAKERS ARE ALL REQ'D TO BE RATED FOR | | | THE AVAILABLE FAULT CURRENT. 110.9 | | | | | | 5)NOTE: PLEASE SEE PLAN, SHOWS ONLY ONE | | | DISC AT SERVICE LOCATION. | | | | | | 6)NOTE: PLEASE LIST ALL THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE. PLEASE SEE THAT WE ARE NOW | | | UNDER THE 2002 NEC AND ARC FAULT PROTECT | | | -ION IS NO LONGER JUST RTECEPTS. | | | | | | 7)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | | FOR ALL ROOMS. | | | | | | 8)NOTE: PLEASE MOVE SD IN MASTER BEDRM? | | | INTO SLEEPING AREA. NFPA-72 8-4 | | | | | | 9)NOTE: PLEASE SEE THAT RECEPTS ARE TO | | | BE W/IN 3' OF LAV/SINKS. (MAST)? | | | 210.52D | | | | | | 10)NOTE: SD'S ARE REQ'D INSIDE AND OUT- | | | -SIDE ALL SLEEPING ROOMS AND ALSO | | | ADAPTABLE SLEEPING RMS. THESE RMS THAT | | | MAY CONTAIN A CLOSET OR BATH RM. | | | NFPA-72 | | | | | | 11)NOTE: PLEASE SEE MISSING RECEPT IN- | | | FRONT OF DWELLING UNIT. 210.52E | | | | | | 12)NOTE: PLEASE SHOW RECEPT REQ'D FOR | | | GARAGE (210.52G) AS GFI. 210.8 | | | | | | 13)NOTE: PLEASE SHOW MISSING REQ'D LT | | | AND RECEPT FOR ATTIC. 210.70 AND 210.63 | | | | | | 14)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS. | | | | | | 15)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED. 210.8(A)(6) | | | | | | 16)NOTE: PLEASE CLARIFY CIRCUIT #11? | | | SHOWN AS 15A/ #14? | | | | | | 17)NOTE: PLEASE SEE THAT AN ADDITIONAL | | | RECEPT IS REQ'D AT THE END OF PENINSULAR | | | PLEASE SEE 210.52C 1-5 | | | | | | PLEASE SEE THAT ONE SET OF PLANS HAVE | | | MOST OF THE ABOVE ITEMS HIGHLIGHTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-05 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
| 2005-01-05 00:00:00 | TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
15:20 |
Sent To |
B |
|
| Notes |
| 2004-09-22 00:00:00 | TO JG DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-19 |
Time |
16:38 |
Sent To |
E |
|
| Notes |
| 2004-02-19 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-12 |
Time |
16:17 |
Sent To |
P |
|
| Notes |
| 2004-02-12 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-14 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-14 |
Time |
13:06 |
Sent To |
E |
|
| Notes |
| 2004-01-14 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2003-12-10 |
Time |
15:21 |
Sent To |
PC |
|
| Notes |
| 2003-12-10 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-01 |
Time |
12:48 |
Sent To |
PC |
|
| Notes |
| 2003-11-17 00:00:00 | CALLED CONTRACTOR. PLANS UNDER "C". | | 2003-10-16 00:00:00 | 10/03/03TO Z | | | 10/15/03TO Z RESUB | | | 10/16/03TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-01 |
Time |
07:39 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-26 |
Time |
16:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-21 |
Time |
17:15 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-10-29 |
Time |
17:30 |
Sent To |
B |
|
| Notes |
| 2003-10-29 00:00:00 | NO MECHANICAL PLANS.10/29/03 H.M. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-01-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-22 |
Time |
14:27 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-22 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2005-01-22 00:00:00 | AS BUILTS BY PLUMBER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-01 |
Time |
07:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-01 |
Time |
07:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-20 |
Time |
06:28 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-02-18 |
Time |
08:00 |
Sent To |
E |
|
| Notes |
| 2004-02-18 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT | | | ADDRESSED. CERTIFICATE OF AUTHORIZATION | | | REQUIRED FOR ARCHITECTURAL COMPANY. | | | FS 481.219(2). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
16:17 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-01-21 |
Time |
17:13 |
Sent To |
M |
|
| Notes |
| 2004-01-21 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES | | | | | | 1) CERTIFICATE OF AUTHORIZATION REQUIRED | | | ON TITLE BLOCK PER FS 481.219 SUBSECTION | | | (2). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-20 |
Time |
16:43 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-10-28 |
Time |
18:12 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-04 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-04 |
Time |
14:42 |
Sent To |
B |
|
| Notes |
| 2004-03-04 00:00:00 | RE-STAMP SITE PLAN MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | 10/6/03 DENIED, OVER THE HEIGHT | | | REQUIREMENT OF 4FT.MAX HEIGHT REQ IS | | | 30FT WITH 10% ADDT'L OF 3FT. CALLED | | | LEFT MSG FOR HENRY FILE C MM |
|
|