Plan Review Details - Permit 03091916
| Plan Review Stops For Permit 03091916 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-10 |
Time |
18:37 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-10-14 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | BUILDING PROVISO: | | | SHOW METHOD OF PROTECTING THE POOL FROM | | | THE HOUSE OPENINGS TO POOL AREA. LS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-08 |
Time |
18:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-08 |
Time |
18:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-15 |
Time |
12:39 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-02 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-26 |
Time |
15:53 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
06:32 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-25 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
12:39 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-10 |
Time |
18:37 |
Sent To |
B |
|
| Notes |
| 2003-10-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | | BASE IN A MANNER THAT WILL ELIMINATE | | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | | AL 4" THICK. (DETAIL) | | | 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | | ORD. #2853-95, BACKFLOW REQUIRED ON | | | WATER SERVICE. (ADD TO NOTES) | | | 3) FBC-2001 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 4) FBC-2001 424.2.13.2JOINTS AND CON- | | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | | NOTES) | | | 5) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | | LED WITH FLANGES OR UNION CONNECTIONS | | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | 6) FBC02001 424.2.15 GAS PIPING SHALL | | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | | AND PERMIT REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-26 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|