Plan Review Details - Permit 03091790
| Plan Review Stops For Permit 03091790 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-12-13 |
Time |
07:13 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-11-29 |
Time |
11:20 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-26 |
Time |
13:37 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-10-14 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | ****CORRECTIONS***** | | | | | | 1.)THE PERMIT APPLICATION STATES THAT | | | THIS IS A PERMIT TO REPAIR A WALL.THE | | | PLAN SHOWS EXISTING CONDITIONS AND | | | PROPOSED GLASS BLOCK WINDOW AND | | | PROPOSED SHOWER.PROVIDE A DETAIL OF | | | THE STRUCTURAL REPAIR (WALL SECTION). | | | HAVE THE WALL SECTION REVIEWED/STAMPED | | | BY THE HISTORIC PRESERVATION DEPT. | | | | | | 2.)SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR THE GLASS BLOCK. | | | | | | 3.)PREINSPECT REQUIRED; CALL 805-6668. | | | | | | 4.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-05-28 |
Time |
12:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-05-28 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-12-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
13:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-01 |
Time |
09:08 |
Sent To |
P |
|
| Notes |
| 2003-12-01 00:00:00 | | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION FOR REVIEW TO DETERMINE CODE | | | COMPLIANCE.RESUBMIT SAME. | | | | | | 1} A FLOOR PLAN SHOWING THE LOCATION OF | | | THE NEW EQUIPMENT,AND THE FEEDER SIZE | | | AND OVERCURRENT PROTECTION LOCATION AND | | | SIZE. | | | | | | 2} A DIAGRAM SHOWING HOW THE NEW PANEL | | | IS BEING FED. | | | | | | 3} RATING OF THE NEW PANEL. | | | | | | 4} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110.9. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-27 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-27 |
Time |
13:42 |
Sent To |
E |
|
| Notes |
| 2004-05-27 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-26 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-26 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
| 2003-11-26 00:00:00 | TO ST DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-25 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-25 |
Time |
14:32 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-12-13 |
Time |
07:13 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-12-13 |
Time |
07:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-01 |
Time |
09:54 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-10 |
Time |
13:07 |
Sent To |
B |
|
| Notes |
| 2003-10-10 00:00:00 | EXISTING SANT. SHOWN - O/B SAYS REPLAC- | | | ING SHOWER PAN AND NEW WATER PIPING ONLY | | | (CAR HIT HOUSE) |
|
|
|