Plan Review Details - Permit 03091609
| Plan Review Stops For Permit 03091609 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-22 |
Time |
13:31 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-10-22 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-28 |
Time |
07:00 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-10-28 |
Time |
06:48 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
14:25 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-10-22 |
Time |
13:28 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | 1} PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | 2} A TIME CLOCK IS REQUIRED ON PRIVATE | | | POOLS PER 612.1.ABC.2.3.3.FBC. | | | | | | BILL TROBAUGH | | | ELCTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2003-10-24 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
15:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-24 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-24 |
Time |
14:50 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-31 |
Time |
13:34 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-31 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-28 |
Time |
07:00 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-20 |
Time |
11:06 |
Sent To |
E |
|
| Notes |
| 2003-10-20 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | | | | 1) 61G15-23.002(1) THE DATE THAT THE | | | SIGNATURE AND SEAL IS AFFIXED AS PROVID- | | | ED HEREIN SHALL BE ENTERED ON PLANS. | | | EACH SHEET REQUIRES THE DATE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-10-15 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-09-30 00:00:00 | 9/30/03 DENIED, NEED TO BE 3FT ON THE | | | SIDE (DECK) CALLED CONTR FILE T MM |
|
|
|