Plan Review Details - Permit 03091375
Plan Review Stops For Permit 03091375
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-16 Cont ID  
Sent By rmcdouga Date 2004-01-16 Time 10:45 Rev Time 2.00
Received By rmcdouga Date 2004-01-16 Time 10:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-29 Cont ID  
Sent By rmcdouga Date 2003-10-29 Time 16:50 Rev Time 3.00
Received By rmcdouga Date 2003-10-29 Time 16:50 Sent To  
Notes
2003-10-29 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3)PLEASE REMOVE THE DESIGN CERTIFICATION
 FORM, WHICH CONTAINS INCORRECT DESIGN
 CRITERIA, FROM SHEET C-1.
  
 4) FBC 1609.4 NO LONGER ALLOWS A ONE-
 THIRD INCREASE IN THE STEEL CALCULATIONS
 FOR COMBINED LOADS. PLEASE REVISE THE
 UPLIFT VALUES OF TRUSS CONNECTORS TO THE
 VALUES IN THE 2003 USP CATALOG WHICH DO
 NOT INCLUDE THE STRESS INCREASE. REVISE
 THE TRUSS CONNECTOR SCHEDULE ON A12 &
 A13 AND DETAILS 11 & 34 ON A11.
  
 5) SUBMIT A CURRENT PRODUCT FOR THE
 STORM PANELS. THE SCHEDULE FOR THE
 BEGONIA MODEL INDICATES THAT THE ENTIRE
 DOOR AND SIDELITE OPENING IS BEING
 SHUTTERED. PLEASE REVISE TO SHOW THAT
 ONLY THE SIDELITE IS BEING SHUTTERED.
 PROVIDE A SCHEDULE AND KEY PLAN FOR THE
 DATURA MODEL (2ND FLOOR) SHOWING THAT
 THE SIDELITE AT THE ENTRY IS SHUTTERED.
  
 6) SUBMIT THE SBCCI PRODUCT EVALUATION
 REPORT THAT CORRESPONDS WITH THE DRAWING
 FOR THE CLOPAY GARAGE DOOR THAT WAS
 SUBMITTED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-12-29 Cont ID  
Sent By dpalmer Date 2003-12-29 Time 07:17 Rev Time 0.33
Received By dpalmer Date 2003-12-29 Time 07:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-07 Cont ID  
Sent By dpalmer Date 2003-10-07 Time 18:17 Rev Time 0.33
Received By dpalmer Date 2003-10-07 Time 18:17 Sent To  
Notes
2003-10-07 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE SEE THAT AS OF JULY 1ST,
 2003, WE ARE NOW UNDER THE 2002 NEC.
 PLEASE ADJUST PLANS AND REFERENCES.
  
 2)NOTE: PLEASE SEE THE 2002NEC, 210.12
 IT IS NOT JUST RECEPTS.
  
 3)NOTE: PLEASE CORRELATE RISER AND
 PANEL SCHEDULE FOR A/C COMPRESSOR.
 ONE SHOWS 30A AND OTHER 40A?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-10-17 Cont ID  
Sent By mcarsill Date 2003-10-17 Time 17:00 Rev Time 0.00
Received By mcarsill Date 2003-10-17 Time 16:58 Sent To  
Notes
2003-10-17 00:00:001) WET FIRE HYDRANTS ARE REQUIRED
 PRIOR TO, DURING, AND AFTER
 CONSTRUCTION.
  
 2) BUILDING ADDRESS REQUIRED.
  
 3) PORTABLE FIRE EXTINGUISHERS
 REQUIRED.
  
 4) SLEEPING ROOMS SHALL COMPLY WITH
 SEC 1005.4 FBC, EMERGENCY EGRESS
 REQUIREMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-17 Cont ID  
Sent By csiegber Date 2003-12-17 Time 09:07 Rev Time 0.00
Received By csiegber Date 2003-12-17 Time 09:07 Sent To  
Notes
2003-12-17 00:00:00TO COMM BD#60

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-09-29 Cont ID  
Sent By mmclean Date 2003-09-24 Time 16:52 Rev Time 0.00
Received By csiegber Date 2003-09-23 Time 14:37 Sent To Z
Notes
2003-09-29 00:00:00TO COMM BD #43

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-12-30 Cont ID  
Sent By pkrauss Date 2003-12-30 Time 11:47 Rev Time 0.45
Received By pkrauss Date 2003-12-30 Time 11:46 Sent To  
Notes
2003-12-30 00:00:00PROVISO:
 RETURN AIR FROM THE MASTER BEDROOM SHALL
 COMPLY WITH THE REVISION TO THE 2001
 FBC(M) 601.4 #1 (SEE BELOW)

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-10-31 Cont ID  
Sent By pkrauss Date 2003-10-31 Time 08:26 Rev Time 0.55
Received By pkrauss Date 2003-10-31 Time 07:43 Sent To  
Notes
2003-10-31 00:00:00DENIED:
 1.ENERGY CALCULATION FOR MODEL D ITEM
 #2. INDICATES "SINGLE FAMILY".SHOULD
 READ MULTI-FAMILY.
  
 2.NOTE #7, O.A. USING 4% OF OPERABLE
 WINDOWS.AS PER 2001 FBC(M) 403.3,
 MULTI-FAMILY IS NOT CONSIDERED ONE AND
 TWO FAMILY DWELLING (R-3 OCCUPANCY)
 THEREFORE IS REQUIRED TO MEET THE
 REQUIREMENTS FOR OUTSIDE AIR AS
 INDICATED ON TABLE 403.3.
  
 3.RETURN TRANSFER DUCTS ARE NOT SIZED
 CORRECTLY REFERENCE 2001 FBC(M) 601.4
 EXCEPTION #1. (SEE ATTACHED SHEET)

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-01-16 Cont ID  
Sent By rmcdouga Date 2004-01-16 Time 10:43 Rev Time 0.00
Received By rmcdouga Date 2004-01-16 Time 10:43 Sent To  
Notes
2004-01-16 00:00:00RESTAMP NEW PLAN

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-10-22 Cont ID  
Sent By kstevens Date 2003-10-22 Time 07:21 Rev Time 0.50
Received By kstevens Date 2003-10-22 Time 07:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-09-24 Cont ID  
Sent By csiegber Date 2003-09-29 Time 08:14 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
2003-09-24 00:00:009/24/03 GIVEN TO BILL STAPLES MM

Review Stop Z ZONING
Rev No 1 Status F Date 2003-09-23 Cont ID  
Sent By csiegber Date 2003-09-23 Time 14:37 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-09-23 00:00:009/23/03 BLDG EXCEED THE BUILDING HEIGHT
 REQUIREMENT OF 33FT (BLDG IS 37FT IN
 HEIGHT) CALLED JOHN FOR PICK UP FILE
 E MM