| Plan Review Stops For Permit 03091329 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
F |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-15 |
Time |
13:18 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-11-15 |
Time |
13:18 |
Sent To |
PC |
|
| Notes |
| 2004-11-15 00:00:00 | ****CORRECTIONS**** | | | BAR JOIST SUBMITTAL, PREPARED BY AMIN | | | FARES, PE DATED 11/9/4 | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PROVIDE A TITLE BLOCK INCLUDING AN | | | ADDRESS, TELEPHONE, PRINTED NAME AND | | | LICENSE NUMBER ON EACH SHEET, | | | FAC61G15-23.002. | | | | | | 2.)EACH SHEET IS TO BE SIGNED AND | | | SEALED BY THE ENGINEER. | | | | | | 3.)REVIEW BY DESIGNER OF RECORD IS TO | | | BE DONE BEFORE RESUBMITTAL. | | | | | | 4.)THE ADDRESS ON THE SUBMITTAL IS | | | NOT FOR THIS JOB. | | | | | | 5.)CHANGES TO THE PLAN REQUIRE A | | | REVISION; WHEN RESUBMITTING PLEASE | | | BRING IN AS A REVISION. | | | | | | 6.)FOR THE MECHANICAL EQUIPMENT | | | HANGING FROM THE BOTTOM CHORD OF THE | | | BAR | | | JOISTS, CONFIRM THAT LATERAL RESTRAINTS | | | HAVE BEEN ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-09 |
Time |
13:22 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-09 |
Time |
13:22 |
Sent To |
PC |
|
| Notes |
| 2004-11-09 00:00:00 | ROOFING SUBMITTAL, STAIR SHOPS, LIGHT | | | POLE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
F |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-20 |
Time |
15:58 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-08-20 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2004-08-20 00:00:00 | ****CORRECTIONS**** | | | ROOFING SUBMITTALS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SUBMITTALS/REVISIONS ARE TO BE | | | REVIEWED BY THE DESIGNER OF RECORD. | | | | | | 2.)ORIGINAL SIGNED, SEALED CALCS | | | REQUIRED FAC61G15-23.002.THE CA NUMBER | | | FOR THE ENGINEERING FIRM IS TO BE ON | | | THE TITLE BLOCK. | | | | | | 3.)NO FEE FOR RESUB (BRING IN AS A | | | SUBMITTAL AS IT HAS ALREADY BEEN | | | REVIEWED). | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
14:39 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-08-17 |
Time |
09:35 |
Sent To |
PC |
|
| Notes |
| 2004-08-17 00:00:00 | REVISION - ARCH ALUM PROD APPROVAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-11 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-07-28 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | LETTER FROM MARK DUCKETT, PE RE: FIELD | | | ISSUES, REQUEST OF HP DATED 7/12/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-27 |
Time |
13:58 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-07-27 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2004-07-27 00:00:00 | LETTERS FROM MARK DUCKETT, PE AND | | | MANUEL R. LINARES, III, PE REGARDING | | | SLAB BRACING OF TILT WALLS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
16:41 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-23 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | STEEL SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-21 |
Time |
15:06 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-17 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | TILT PANEL REINFORCING SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-17 |
Time |
07:22 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-17 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | REVISION - DETAIL BY DUCKETT ENGINEERING | | | DATED 5/17/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
11:26 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-06-10 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | WEST FOOTING REVISION | | | PROVISO - REVISE FOUNDATION PLAN TO | | | REFLECT CHANGE IN SIZE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-10 |
Time |
16:56 |
Rev Time |
0.75 |
| Received By |
shill |
Date |
2004-06-10 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | SUBMITTALS | | | | | | FORM BOARD SURVEY | | | FOUNDATION SHOPS | | | ANCHOR BOLTS | | | PANEL WALL LAYOUT SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-04 |
Time |
14:36 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-05-11 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | RESTAMP FOR RESIDENT INSPECTOR SET - | | | ORIGINAL SIGNATURES & SEALS SUBMITTED | | | OVER PHOTOCOPIED CITY APPROVED SET |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-26 |
Time |
14:07 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-04-26 |
Time |
14:07 |
Sent To |
E |
|
| Notes |
| 2004-04-26 00:00:00 | ****CORRECTIONS**** | | | RESIDENT INSPECTOR SET SUBMITTED | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.) ORIGINAL SIGNATURE REQUIRED, NOT | | | PHOTOCOPY. | | | | | | 2.) FOR THE MEP SHEETS, PLEASE CLARIFY | | | AS TO WHY THE SIGNATURE ON THE CITY | | | SET OF PLANS IS DIFFERENT FROM THE | | | SIGNATURE ON THE NEW SHEETS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-16 |
Time |
09:13 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-03-16 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2004-03-16 00:00:00 | SEE PROVISOS ON REVIEW #4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-05 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-03-05 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2004-03-05 00:00:00 | SEE LETTER FROM ENGINEERING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-02 |
Time |
07:27 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-03-02 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | ***PROVISO*** | | | | | | PROVIDE SIGNED & SEALED WIND LOAD CALCS | | | FOR THE LIGHT POLES ASCE7-98 PER FBC16. | | | | | | GUARDRAIL TO COMPLY WITH FBC1015.3 AND | | | 1608, SHOP DRAWINGS TO BE SUBMITTED | | | BEFORE INSTALLATION. | | | | | | NOTICE OF COMMENCEMENT TO BE PROVIDED | | | TO CONSTRUCTION SERVICES BEFORE | | | COMMENCING WORK. | | | | | | RESIDENT INSPECTOR TO BE APPROVED BY | | | CITY OFFICIALS BEFORE COMMENCING WORK. | | | | | | THIRD SET OF PLANS, SIGNED & SEALED, | | | SUBMITTED TO THE CITY BEFORE COMMENCING | | | WORK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
12:20 |
Rev Time |
5.00 |
| Received By |
shill |
Date |
2004-02-11 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2004-02-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE WIND LOAD CALCS, PREPARED BY | | | PCSI, APPEAR TO HAVE A PHOTOCOPY OF A | | | SEAL AND SIGNATURE.TITLE BLOCK | | | REQUIRED, CALCULATIONS TO BE SEALED ON | | | THE FIRST PAGE FAC61G. | | | | | | 2.)SEE THE PREVIOUS LIST, ITEM #1. | | | THE ENERGY CALCS STILL DECLARES "STORAGE | | | & WAREHOUSE" OCCUPANCY, SEE HIGHLIGHT. | | | | | | 3.)DELETED 2/19. | | | | | | 4.)DELETED 2/19. | | | | | | 5.)SEE PREVIOUS LIST, ELECTRICAL | | | COMMENT #1, 12/29/03. | | | TITLE BLOCKS ARE REQUIRED TO | | | CONTAIN AN AUTHORIZATION NUMBER FOR | | | THE COMPANY AND A SPACE FOR THE PRINTED | | | NAME AND LICENSE NUMBER OF THE PERSON | | | SEALING THE PLAN, FAC61G15-23.002, | | | FAC61G1-16.004.CHECK ALL SHEETS FOR | | | COMPLIANCE. | | | | | | 6.)SEE PREVIOUS LIST, ITEM #1.THE | | | SHEETS A1 AND A2 PREPARED BY ZPR STILL | | | DECLARE A FLEX/WAREHOUSE USE.THE | | | ELEVATIONS ARE NOT CONSISTENT WITH THE | | | PLAN.WHY HAS THIS INFORMATION NOT | | | BEEN PREPARED BY THE DESIGNER OF RECORD? | | | ADDRESS. | | | | | | 7.)THE UNITY OF TITLE STATES THE | | | INCORRECT USAGE OF THE PROPERTY "FLEX | | | SPACE".ALSO, THE ACKNOWLEDGEMENT IS | | | BY ANDREW AIKEN ON BEHALF OF JUPITER | | | TRADE CENTER PARTNERS.ADDRESS.SUBMIT | | | AN ORIGINAL CORRECTED UNITY OF TITLE. | | | | | | 8.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 9.)SEPARATE PERMITS REQUIRED. | | | | | | 10.) SEE PREVIOUS ELECTRICAL COMMENT, | | | REMOVE VOIDED SHEETS. | | | | | | 11.) PROVISO - GUARDRAIL TO COMPLY WITH | | | FBC1015.3, SHOP DRAWINGS TO BE SUBMITTED | | | BEFORE INSTALLATION. | | | | | | 12.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 13.)ANY PRODUCT APPROVALS REQUIRED BUT | | | NOT SUBMITTED BEFORE ISSUANCE WILL | | | REQUIRE A SEPARATE PERMIT FOR THOSE | | | ITEMS. | | | | | | **NO RESUB FEE PER LM/SMH** | | | | | | NOTE 2/19/3 - CONTACT R.PITTMAN UPON | | | RESUBMITTAL; NEEDS COPY OF SURVEY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2004-02-02 |
Time |
08:58 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-01-03 |
Time |
21:06 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | ******CORRECTIONS****** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST, FIRST | | | CORRECTION.THE PERMIT APPLICATION WAS | | | CHANGED TO "BUSINESS OCCUPANCY" (FROM | | | WAREHOUSE), BUT THE ENERGY CALCS AND | | | THE PLANS (ZPR) STATE FLEX OFFICE/IND/ | | | WAREHOUSE. | | | | | | 2.)SEE PREVIOUS LIST IN REGARDS TO | | | THE REQUEST FOR FIRE PROTECTION | | | DESIGN.THE TRANSMITTAL LETTER STATES | | | THAT DRAWINGS WERE SUBMITTED BUT THEY | | | ARE NOT IN THE PACKAGE.FBC104.3.1.1. | | | | | | 3.)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 4.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 5.)SEPARATE PERMITS REQUIRED. | | | | | | 6.)IMPACT PROTECTION REQUIRED FOR | | | GLAZING FBC1606.1.4.THE PRODUCT | | | APPROVALS FOR THE STOREFRONT GLASS WAS | | | FOR IMPACT BUT THE DOORS WERE NON | | | IMPACT. | | | | | | 7.)UNITY OF TITLE REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-12-22 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-27 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2003-10-27 00:00:00 | SHEET A1 DECLARES THE OCCUPANCY GROUP | | | AS"B" OFFICE USE.THE PERMIT | | | APPLICATION DECLARES WAREHOUSE USE. | | | PLEASE CLARIFY THE DESIGN INTENT, EVEN | | | IF MIXED OCCUPANCY, SHOW THE | | | PROPORTIONS.NOTE THE QUANTITIES, | | | NATURE AND CHARCTERISTICS OF THE | | | COMMODITIES TO BE STORED IN ANY GROUP | | | "S" OCCUPANCIES. | | | | | | THE FIRE PROTECTION DESIGN IS REQUIRED | | | TO BE ON THE PERMIT PLANS.SEE FBC 104. | | | 3.1.1 #5. | | | | | | ARE THE THREE MEZZANINES SHOWN TO BE | | | CONSTRUCTED WITH THIS PERMIT?IF SO, | | | INCLUDE THE FLOOR AREA IN THE DATA ON | | | SHEET A1.ALSO, SHOW THE VERTICAL | | | ACCESSIBILITY AS PROVIDED FOR IN FBC | | | 11-4.1.3 (5). | | | | | | PLEASE PROVIDE A DETAIL FOR THE | | | EXTERIOR RUSTICATIONS SHOWN IN SEVERAL | | | PLACES ON THE PLANS. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE, AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | ALSO, SEE THE NOTE ABOVE RE: OCCUPANCY U | | | SE GROUPS AND AREAS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2004-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-23 |
Time |
09:07 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-23 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-06 |
Time |
17:07 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-06 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2004-10-06 00:00:00 | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE A REVISION #2 IS | | | INDICATED ON TITLE BLOCK, YET PLANS DO | | | NOT SHOW THIS REV #2 WITH CLOUDS/TRI- | | | -ANGLES? | | | | | | 2)NOTE: PLEASE SEE FS 471.025, PLANS | | | REQUIRED TO BE SIGNED WITH SIGNATURE. | | | SIGNATURE MUST BE LEGAL SIGNATURE AND | | | CORRELATE WITH SIGNATURE ON FILE PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-17 |
Time |
13:09 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-09-16 |
Time |
20:18 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | ******** UNSAT ***** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE NOW BEING | | | SUBMITTED FOR A TEANT BUILD OUT. | | | ANY REVISIONS TO ORIGINAL PLANS, MUST BE | | | DONE BY THE ENGINEER OF RECORD. | | | SPACE CAN BE DONE UNDER SEPARATE PERMIT. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-11 |
Time |
09:14 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-05-11 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | COPY OF ORG SET ONLY, NO REVISION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-10 |
Time |
13:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-28 |
Time |
07:26 |
Sent To |
P |
|
| Notes |
| 2004-04-28 00:00:00 | ********** UNSAT ********** | | | | | | 1)NOTE: PLANS ARE REQ'D TO BE SIAGNED | | | W/ COMPLETE SIGNATURE PER FS 471.025 | | | PLANS APPEAR TO HAVE INITIALS WHICH ARE | | | NOT ACCEPTABLE PER FS/ FAC . | | | DO NOT CORRELATE WITH PLANS ON FILE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-26 |
Time |
14:39 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-02-05 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-29 |
Time |
13:13 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-12-29 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE THAT ALL LICENSE #`S | | | ARE REQ'D ON PLANS/TITLE BLOCK. | | | PER FS 471 AND FAC 61G15-23.002 | | | PLEASE SEE THAT THIS WAS ADDED ON ONLY | | | TWO OF THE ELECTRICAL SHEETS. OTHER OLD | | | SHEETS WERE NOT CORRECTED. | | | PLEASE NOTE, THIS IS REQ'D ON ALL SHEETS | | | AND FOR ALL TRADES, WEATHER OR NOT | | | COMMENT IS MADE FROM OTHER REVIEWERS. | | | | | | 2)NOTE: PLEASE SHOW WIND LOADING FOR | | | POLES. THIS IS REQ'D AT THIS TIME AND ON | | | THESE PLANS. | | | | | | 3)NOTE: PLEASE TAKE OUT ALL OLD/VOIDED | | | SHEETS AND ONLY HAVE NEW SHEETS INTO | | | SETS FOR REVIEW AND STAMPING. | | | | | | 4)NOTE: PLEASE HAVE PLANS "SIGNED" WITH | | | A COMPLETE SIGNATURE PER FS 471.025 AND | | | FAC 61G15-23.002. | | | PLEASE NOTE, SINCE DATE OF LAST REVIEW | | | WE HAVE BEEN NOTIFIED FROM THE FBPE'S | | | THAT INITIALS ARE NOT ACCEPTABLE AND | | | SHOULD BE SIGNED HOW SIGNATURE ON | | | LICENSE WAS SIGNED W/ FBPE'S. | | | IF THIS IS ACTUAL SIGNATURE, PLEASE | | | PROVIDE COPY OF LICENSE WITH SIGNATURE | | | SHOWN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE NAY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-14 |
Time |
09:46 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-14 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE CIRCUIT EM/ EXT LTS PER | | | 700.12E AND CORRELATE. | | | | | | 2)NOTE: PLEASE CORRELATE A/C SYSTEMS | | | AND PANEL SCHEDULES, CIRCUITING SHOWN ON | | | PLANS DIFER FROM PANELS. | | | | | | 3)NOTE: PLEASE INCLUDE ALL LICENSE | | | INFORMATION ON TITLE BLOCK(CA#) REQ'D | | | UNDERFAC 61G15-23.002, FS 471 | | | | | | 4)NOTE: PLEASE LABEL ALL DISC MEANS | | | AT MAIN.600A,400A,300A ETC. WHICH ONE | | | DOES WHICH.? 215.5 | | | | | | 5)NOTE: PLEASE PROVIDE AIC RATINGS FOR | | | ALL MAINS. 110.9/215.5 | | | | | | 6)NOTE: PLEASE PROVIDE LOAD CALCAULTIONS | | | WITH ALL CONTINUOUS LOADS AT 125%. | | | 215.3/230.42 ETC. | | | | | | 7)NOTE: PLEASE PROVIDE INFORMATION FOR | | | WIND LOADS ON LIGHT POLES. REQ'D AT THIS | | | TIME. | | | | | | 8)NOTE: PLEASE SEE THAT ADDRESS IS REQ`D | | | ON PLANS FOR LOCATION OF JOB/SITE. | | | 61G1-16.004. | | | | | | PLEASE PROVIDE THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-01 |
Time |
16:21 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-03-01 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2004-03-01 00:00:00 | M.A. TO ADD PROVISO | | | PASSED WITH PROVISOS: | | | 1. WORK WITHIN PUBLIC R.O.W REQUIRES | | | PERMIT FROM CITY ENGINEER, MR. RICHARD | | | PITTMAN.PROPOSED SIDEWALK AND THE | | | APPRACHES MUST BE APPROVED AND PERMITTED | | | BY THE CITY ENGINEER, 659-8040. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-12-30 |
Time |
09:55 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-12-30 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-06 |
Time |
08:38 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-10-06 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE STORM WATER | | | CALCULATION FOR OUR REVIEW AND APPROVAL, | | | CALCULATION MUST INCLUDE TOTAL SITE, | | | PERVIOUS AND IMPERVIOUS AREA. | | | 2. PARKING STALLS MUST BE DIMENSIONED | | | PER ZONING DEPARTMENT REQUIREMENT. | | | 3. PLEASE CONTACT JIM WITMER FOR | | | ADDRESSING THE FACILITIY AND FOR PROPER | | | PROPERTY CONTROL NUMBER, 805-6715 | | | 4.PLEASE SUBMIT TWO COPIES OF CIVIL PLAN | | | ONLY TO PUBLIC UTILITIES AND ENGINEERING | | | FOR THEIR REVIEW AND RECORD.659-8040, | | | EXT. 2306 MANNY GONZALEZ | | | 5. PLEAE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORK IS REQUIRED, | | | PLEASE SUBMIT TWO SETS OF CIVIL PLANS | | | SIGNED AND SEALED AND WITH THE | | | INFORMATION REQUESTED. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-11-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-11-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-02-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-02-10 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-02-10 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-02 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-02 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | APPROVED PROVISO: | | | | | | 1) DUCT SMOKE DETECTORS SHALL CAUSE | | | A GENERAL ALARM NOT A SUPERVISORY | | | SIGNAL AS LISTED AS # 13, FIRE CONTROL | | | COMMUNICATOR SYSTEM NOTES. | | | | | | 2) FIRE ALARM SYSTEM SHALL BE UL LISTED | | | FOR CENTRAL STATION SERVICE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-08 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-08 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2003-10-08 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING, AND AFTER CONSTRUCTION. | | | | | | 2) BUILDING ADDRESS IS REQUIRED. | | | | | | 3) THE FIRE ALARM SYSTEM IS TO BE UL | | | CERTIFICATED FOR CENTRAL STATION | | | SERVICE. NOTES ON PAGE E-1 SUGGESTS | | | FLOW AND TAMPER SWITCHES, HOWEVER NO | | | FIRE SPRINKLER PLANS WERE PROVIDED. | | | LIMITED FIRE SPRINKLER INFORMATION | | | WAS PROVIDED ON PAGES A-1 AND A-3. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-17 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-17 |
Time |
16:14 |
Sent To |
M |
|
| Notes |
| 2004-11-17 00:00:00 | SENT TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-09 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-09 |
Time |
10:12 |
Sent To |
B |
|
| Notes |
| 2004-11-09 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2004-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-04 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-04 |
Time |
13:13 |
Sent To |
B |
|
| Notes |
| 2004-11-04 00:00:00 | TO SH DESK/SUBMITTALS/PA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-20 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-20 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2004-10-20 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2004-10-05 00:00:00 | TO COMM BD#61 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-31 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-31 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2004-08-31 00:00:00 | TO COMM BD#52 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-20 |
Time |
14:39 |
Sent To |
B |
|
| Notes |
| 2004-08-20 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-11 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-11 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2004-08-11 00:00:00 | TO SH DESK/SUBMITTAL/PA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
16:41 |
Sent To |
B |
|
| Notes |
| 2004-07-26 00:00:00 | TO SH DESK/SUBMITTAL | | | CONNECTION SYSTEM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-21 |
Time |
09:36 |
Sent To |
B |
|
| Notes |
| 2004-07-21 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-21 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-21 |
Time |
15:06 |
Sent To |
B |
|
| Notes |
| 2004-06-21 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-16 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
| 2004-06-16 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-06-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-04 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-04 |
Time |
14:36 |
Sent To |
B |
|
| Notes |
| 2004-06-04 00:00:00 | TO SH DESK/SUBMITTAL/3-FORM BOARD SURVEY | | | FOUNDATION STEEL DRAWINGS,ANCHOR BOLT | | | DRAWINGS,PAN LAYOUT DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-10 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-05-10 |
Time |
13:34 |
Sent To |
E |
|
| Notes |
| 2004-05-10 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-01 |
Time |
12:20 |
Sent To |
B |
|
| Notes |
| 2004-03-01 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-02 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-02 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2004-02-02 00:00:00 | TO COMM BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-23 |
Time |
15:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-23 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | TO COMM BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
16:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | TO COMM BD#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2003-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-22 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-22 |
Time |
16:05 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-11-18 |
Time |
17:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-05 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-11-05 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
07:37 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2004-10-07 00:00:00 | DENIED: | | | 1.SIGNATURE IS REQUIRED ON PLANS IN | | | ACCORDANCE WITH FS 471.025.INITIALS | | | ARE NOT CONSIDERED A SIGNATURE. | | | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-11 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | SEE BLDG REVIEW RE RESTAMP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-04 |
Time |
16:07 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-05-04 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | DENIED:RE-STAMP | | | PLEASE NOTE SIGNATURE ON THE RE-STAMP | | | COPY DOES NOT MATCH THE SIGNATURE ON | | | THE ORIGINAL APPROVED SET OF PLANS. | | | SEE COMMENTS FROM SAMANTHA HILL | | | (BUILDING) AND DEWEY PALMER | | | (ELECTRICAL). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-18 |
Time |
14:19 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-02-18 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-06 |
Time |
10:32 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-01-06 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-28 |
Time |
12:03 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-10-28 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2003-10-28 00:00:00 | DENIED: | | | SEE COMMENT #1 BY H. PISKURA, CLARIFY | | | OCCUPANCY TYPE. | | | | | | PLEASE NOTE, ADDITIONAL VENTILANTION MAY | | | BY REQUIRED SHOULD FUTURE OCCUPANT HAVE | | | HAZARDOUS OR NOXIOUS CONTAMINANT ISSUES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-05 |
Time |
13:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-05 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2004-11-05 00:00:00 | REVISION OK - DELETED BUILD-OUT OF BAY | | | NUMBER 12 - SEPARATE PERMIT FOR | | | BUILD-OUT PER PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2004-10-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-09 |
Time |
14:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-09 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2004-10-09 00:00:00 | REVISION/DENIED | | | | | | SIGNATURE ON REVISION IS NOT THE SAME AS | | | THE SIGNATURE ON THE STAMPED SET OF | | | PLANS ON FILE - FULL SIGNATURE OF ENG. | | | OF RECORD REQUIRED ON REVISION - INITI- | | | ALS ARE NOT ACCEPTABLE.RESUBMIT REV- | | | ISION WITH FULL SIGNATURE OR REVISION | | | WILL BE DENIED. FAC 61G15-23.003 | | | FS 471.025 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-11 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-05-11 00:00:00 | SEE BLDG REVIEW RE RESTAMP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-29 |
Time |
18:43 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-04-29 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | DENIED | | | | | | SEE COMMENTS FROM 4-28-4 BY ELECTRICAL | | | PLAN REVIEWER | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-28 |
Time |
07:26 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-03 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-09 |
Time |
18:11 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-01-09 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2004-01-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLA. ADMIN. CODE | | | FLA. STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: (#3) INDICATE | | | THE NAME OF THE PERSON RESPONSIBLE FOR | | | DRAWINGS. 104.2.1 | | | 2) FROM PREVIOUS REVIEW: (#5) CERTIFIC- | | | ATE OF AUTHORIZATION REQUIRED ON EACH | | | SHEET. 61G15-23.002(2) - FS471.025 | | | 3) SEE COMMENT #4 BY ELECTRICAL PLAN | | | REVIEWER. SIGNATURE REQUIRED ON SEAL. | | | INITALS NOT ACCEPTABLE PER FBPE & BLDG. | | | OFFICIAL. | | | 4) PLEASE REMOVE ALL OLD SHEET AND SUB- | | | MIT ONE COPY OF OLD SHEETS FOR COMPARI- | | | SON. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-22 |
Time |
14:24 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2003-10-22 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2003-10-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1) SUBMIT CALCULATIONS FOR ROOF GUTTERS | | | AND DOWNSPOUTS PER TABLE 1106.6. SHOW SQ | | | FT OF ROOF, & SHOW 1/2 AREA OF ALL | | | VERTICAL WALLS INCLUDING PARAPETS IN THE | | | CALCULATIONS. INDICATE SLOPE OF GUTTER, | | | AND SHOW SLOPE OF GUTTER ON PLANS. | | | 2) DRINKING FOUNTAIN SHALL COMPLY WITH | | | SECTION 11-4.15 AND ALL SUBSECTIONS. | | | ALSO 11-4.1.3(10)(A) PROVISIONS SHALL BE | | | MADE FOR THOSE WHO HAVE DIFFICULTY BEND- | | | ING OR STOOPING. PLEASE SUBMIT A DETAIL. | | | 3) SEPARATE IRRIGATION PERMIT/PLANS RE- | | | QUIRED. | | | 4) SHT L-1 ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | 5) CERTIFICATE OF AUTHORIZATION REQUIRED | | | PER 61G15-23.002(2) FS 471 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
15:25 |
Rev Time |
1.00 |
| Received By |
gjoyce |
Date |
2004-02-02 |
Time |
08:57 |
Sent To |
B |
|
| Notes |
| 2003-12-22 00:00:00 | ZONING ISSUES WERE NOT ADDRESSED GMJ | | 2003-10-28 00:00:00 | MET WITH OWNER DO NOT ISSUE PERMIT!!!!! | | | OWNER IS REVISING PLANS TO ADDRESS CODE | | | ISSUSES.HE IS ADDING RESIDENTAIL TO EN | | | TIRE 2ND FLOOR.HE IS REVISING CIRCULAT | | | ION AND LANDSCAPING.DO NOT ISSUE PERMIT! | | | ! | | 2003-09-29 00:00:00 | PARKING SIZE NOT TO CODE, LANDSCAPING NO | | | T TO CODE, DUMPSTER NOT TO CODE THE PLAN | | | S ARE ON THE 5TH FLOOR W/ GRACE.WAITIN | | | G TO SET-UP MEETIN WITH THE OWNER FOR A | | | REDESIGN. |
|
|