| Plan Review Stops For Permit 03091225 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-27 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-27 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-26 |
Time |
15:29 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-11-17 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-29 |
Time |
19:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-29 |
Time |
19:19 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR | | | INFORMATION REQD' ON TITLE BLOCK FOR | | | ENGINEER OF RECORD. PLEASE INDICATE | | | LICENSE # OF ENG WITH THE CA# WHICH | | | APPEARS TO BE SHOWN. | | | | | | 2)NOTE: PLEASE SEE THAT PLANS REFERENCE | | | THE 1991 LS 101. WE ARE CURRENTLY UNDER | | | THE 1999 LS 101 | | | PLEASE ALSO SEE THAT ELECTRICAL CODES | | | REFERENCED ON PLANS ARE FROM THE 1996 | | | NEC.PLEASE SEE THAT AS OF JULY 1ST,2003 | | | THE STATE HAS ADAOPTED THE 2002 NEC. | | | | | | PLEASE SEE FIRE REVIEW COMMENTS THAT MAY | | | HAVE AN AFECT ON ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-24 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-24 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-03 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-03 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) EXITS ARE TO REMAIN TO CLEAR AND | | | UNOBSTRUCTED AT ALL TIMES. | | | | | | 3) DEBRIS TO BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 4) FP-1 DOES NOT INDICATE ANY EXISTING | | | OR NEW FIRE PROTECTION FOR ELECTRICAL | | | ROOM OR JANITOR'S CLOSET. | | | | | | 5) SEPARATE PLANS AND PERMITS REQUIRED | | | FIRE ALARM SYSTEM AND FIRE SPRINKLER | | | REMODEL. | | | | | | 6) PLEASE INDICATE INTERIOR FINISH | | | FOR WALLS AND CEILINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-10 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-10 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2003-11-10 00:00:00 | TO COMM BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-22 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-22 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2003-09-22 00:00:00 | TO COMM BD#25 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-24 |
Time |
13:02 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-11-24 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-20 |
Time |
13:07 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-10-20 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | DENIED: | | | 1.PLEASE NOTE, REVISION TO THE 2001 | | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM ITS SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | 2.AS PER 2001 FBC(M) 601.4, FAN SHUT | | | DOWN BY DUCT SMOKE DETECTOR REQUIRED | | | WITH NOTIFICATION TO ALARM/STROBE IN | | | NORMALLY OCCUPIED AREAS AS PER NFPA 90A | | | 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-21 |
Time |
18:47 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-21 |
Time |
18:47 |
Sent To |
|
|
| Notes |
| 2003-10-21 00:00:00 | NO PLUMBING PLANS SUBMITTED - NO PLUMB- | | | ING WORK SHOWN |
|
|