Plan Review Details - Permit 03091223
| Plan Review Stops For Permit 03091223 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-20 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-20 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-28 |
Time |
06:17 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-28 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2003-10-28 00:00:00 | PASSED PENDING FIRE REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-29 |
Time |
19:04 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-09-29 |
Time |
19:04 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | ******** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE THAT PLANS REFERENCE | | | THE 99 NEC. PLEASE SEE THAT AS OF JULY | | | 1ST, 2003 THE STATE ADOPTED THE 2002 | | | NEC. | | | | | | 2)NOTE: PLEASE SEE FIRE REVIEW NOTES FOR | | | LOCATION OF EXT SIGNS. PLEASE VERIFY | | | FOR NO EXT SIGNS LEADING TO STAIRWELLS? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-04 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2003-11-04 00:00:00 | PLEASE SEE BLOCK STAMP ON PLANS FOR MEC | | | APPROVAL/DEE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-02 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-02 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2003-10-02 00:00:00 | 1) ON SHEET # 4, NO EXIT SIGNS ARE | | | SHOWN AT THE STAIRTOWERS. PLEASE | | | EXPLAIN PURPOSE OF EXIT SIGNS THAT | | | LEAD PERSONS TO THE ELEVATOR LOBBY. | | | | | | 2) IT DOES NOT APPEAR THAT ANY | | | EMERGENCY LIGHTS ARE PRESENT IN THE | | | RECEPTION 101 HALLWAY. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-27 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-27 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2003-10-27 00:00:00 | TO COMM BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-19 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2003-09-19 00:00:00 | TO COMM BD#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
12:08 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-10-10 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-10-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-18 |
Time |
13:40 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-18 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
|