Plan Review Details - Permit 03090799
| Plan Review Stops For Permit 03090799 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2003-10-23 |
Time |
09:25 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-17 |
Time |
11:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-10-17 |
Time |
11:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-24 |
Time |
10:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-09-24 |
Time |
09:26 |
Sent To |
Z |
|
| Notes |
| 2003-09-24 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | TO THE PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} THE LOAD CALCULATIONS SUBMITTED ARE | | | FOR DWELLING UNITS. PLEASE SUBMIT | | | CALCULATIONS AND PANEL SCHEDULES FOR | | | THE COMMERCIAL APPLICATION BEING | | | APPLIED PER 220.3. | | | | | | 2} PLEASE LABEL CIRCUITS ON THE FLOOR | | | PLAN AND CORRELATE WITH THE PANEL | | | SCHEDULE. | | | | | | 3} PLEASE NOTE THAT THE RECEPTACLES IN | | | CLIENT AREAS MUST COMPLY WITH 16.5.1.2 | | | NFPA-72. | | | | | | 4} PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | 5} THE SMOKE DETECTOR IN THE KITCHEN IS | | | IN VIOLATION OF 8-1.4.2 NFPA-72.MUST BE | | | A LISTED HEAT DETECTOR OR REMOVED. | | | | | | NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110.9, | | | IF ANY SERVICE EQUIPMENT IS BEING | | | ADDED OR REPLACED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-10-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-10-01 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-10-01 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2003-10-23 |
Time |
09:25 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-17 |
Time |
11:22 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-10-20 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1) 61G15-23.002(1) 2 SETS OF PLANS HAVE | | | NO SEAL, SIGNATURE, OR DATE ON THEM. | | | 61G15-23.002(2) LICENSE NOT SHOWN ON THE | | | TITLE BLOCK AS REQUIRED. | | | 2) 11-4.1.6(1)(B) IF EXISTING ELEMENTS, | | | SPACES, OR COMMON AREAS ARE ALTERED, | | | THEN EACH SUCH ALTERED ELEMENT, SPACE, | | | FEATURE, OR AREA SHALL COMPLY WITH THE | | | APPLICABLE PROVISIONS OF 11-4.1.1 TO | | | 11-4.1.3. SO PER 11-4.1.3, IF TOILET | | | ROOMS ARE PROVIDED, THEN EACH PUBLIC AND | | | COMMON USE TOILET ROOM SHALL COMPLY WITH | | | 11-4.22. SUBMIT A DETAIL SHOWING COMPLI- | | | ANCE WILL 11-4.22, 11-4.16, & 11-4.19 | | | AND ALL SUBSECTIONS OF EACH. - ALSO SEE | | | SECTION 3401.8.1.1 (BLDG) | | | 3) THE SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN, NOR DOES IS MEET | | | CODE REQUIREMENTS. 909.1 W/M SHALL NOT | | | DRAIN INTO THE HORIZONTAL WET VENT OF | | | THE BATHROOM GROUP OF FIXTURES. 708.10 | | | WASH MACHINE STACK SHALL HAVE A CLEANOUT | | | 4' ABOVE THE FLOOR.SEE ATTACHED RISER | | | FOR AN EXAMPLE OF A RISER THAT MEETS | | | CODE REQUIREMENTS AND REFLECTS THE FLOOR | | | PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-24 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|