Plan Review Details - Permit 03090568
Plan Review Stops For Permit 03090568
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-11-25 Cont ID  
Sent By lsmith Date 2003-11-25 Time 08:06 Rev Time 0.50
Received By lsmith Date 2003-11-25 Time 08:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-09-25 Cont ID  
Sent By btrobaug Date 2003-11-24 Time 08:27 Rev Time 2.00
Received By lsmith Date 2003-09-25 Time 10:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-24 Cont ID  
Sent By btrobaug Date 2003-11-24 Time 08:27 Rev Time 0.50
Received By btrobaug Date 2003-11-24 Time 07:36 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-09-18 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:26 Rev Time 0.25
Received By dpalmer Date 2003-09-18 Time 06:28 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-03-03 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:00 Rev Time 0.00
Received By csiegber Date 2004-03-03 Time 10:00 Sent To P
Notes
2004-03-03 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:25 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 15:26 Sent To E
Notes
2003-11-21 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-06 Time 10:09 Rev Time 0.00
Received By csiegber Date 2003-10-06 Time 10:09 Sent To B
Notes
2003-10-06 00:00:00TO LS DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-16 Time 11:02 Rev Time 0.00
Received By csiegber Date 2003-09-16 Time 11:02 Sent To E
Notes
2003-09-16 00:00:00ON SFD RACK/E

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-09-11 Cont ID  
Sent By mmclean Date 2003-09-16 Time 08:44 Rev Time 0.00
Received By csiegber Date 2003-09-11 Time 10:54 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-23 Cont ID  
Sent By dpalmer Date 2003-09-18 Time 06:43 Rev Time 0.25
Received By pkrauss Date 2003-09-23 Time 08:08 Sent To P
Notes
2003-09-23 00:00:00PROVISO:
 PLEASE NOTE, REVISION TO THE 2001
 FBC(M) 601.4, EFFECTIVE JUNE 30,2003:
  
 BALANCED AIR RETURN - RETURN/TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM ITS SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-13 Cont ID  
Sent By kstevens Date 2004-03-13 Time 16:08 Rev Time 0.50
Received By kstevens Date 2004-03-13 Time 16:08 Sent To  
Notes
2004-03-13 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-09-23 Cont ID  
Sent By csiegber Date 2004-03-03 Time 10:00 Rev Time 0.25
Received By jleech Date 2003-09-23 Time 19:22 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-11 Time 10:54 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***