Plan Review Details - Permit 03090351
| Plan Review Stops For Permit 03090351 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-09-23 |
Time |
20:00 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-10-07 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2003-10-07 00:00:00 | BUILDING PROVISO | | | | | | 1) SUBMIT THE MANUFACTURER'S SPECS. AND | | | UL LISTING INFORMATION FOR PREFAB | | | FIREPLACE. SUBMIT SPECS. AND LISTING FOR | | | FLUE PIPE. SUBMIT SIGNED AND SEALED | | | DRAWINGS OF THE FRAMING, BRACING AND | | | STRAPPING DETAILS FOR CHIMNEY PRIOR TO | | | ROOF FRAMING INSPECTION. | | | | | | 2) SUBMIT SIGNED AND SEALED DRAWINGS OF | | | ANY SPECIAL BRACING OR FRAMING THAT WILL | | | BE REQUIRED AT THE CANTILEVER TRUSSES ON | | | THE COVERED PORCH. | | | | | | 3) SUBMIT SPECIFICATIONS AND LISTING | | | INFORMATION FOR THE OPTIONAL BBQ IF IT | | | WILL BE INSTALLED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
11:06 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-09-17 |
Time |
17:39 |
Sent To |
M |
|
| Notes |
| 2003-09-17 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | THE GEC MUST BE INSTALLED #2 CU PER 210. | | | 66. | | | | | | THE BATH CIRCUITS MUST BE INSTALLED PER | | | 210.11(C)(3),#12 ON A 20A CIRCUIT(S). | | | | | | NOTE THAT PER 210.12 ALL BRANCH CIRCUITS | | | ~~~~~~~~SHALL BE PROTECTED BY ARC FAULT | | | CIRCUIT INTERRUPTER.THAT INCLUDES LIGHT | | | OUTLETS AND SMOKE DETECTORS AS WELL AS | | | RECEPTACLES. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-16 |
Time |
11:06 |
Sent To |
E |
|
| Notes |
| 2003-09-16 00:00:00 | ON SFD RACK/E |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-09-16 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-09 |
Time |
09:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-17 |
Time |
18:08 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-09-23 |
Time |
07:32 |
Sent To |
P |
|
| Notes |
| 2003-09-23 00:00:00 | PROVISO: | | | PLEASE NOTE, REVISION TO THE 2001 | | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM ITS SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-23 |
Time |
07:37 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-09-23 |
Time |
19:59 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-09 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|