Plan Review Details - Permit 03090036
Plan Review Stops For Permit 03090036
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-07-30 Cont ID  
Sent By alange Date 2004-07-30 Time 16:10 Rev Time 1.20
Received By alange Date 2004-07-30 Time 16:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-04-20 Cont ID  
Sent By dpalmer Date 2004-07-28 Time 19:36 Rev Time 1.00
Received By shill Date 2004-04-20 Time 16:35 Sent To  
Notes
2004-04-20 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PRODUCT APPROVALS FOR THE MULLIONS
 AND HORIZONTAL ROLLER WINDOWS ARE
 REQUIRED; SUBMIT TWO COMPLETE LEGIBLE
 COPIES.
  
 3.)SHEET ONE INVOKES SBC2001; WRONG
 BUILDING CODE.
  
 4.)SUBMIT OLD SHEETS SEPARATELY.
  
 5.)SUBMIT A HURRICANE SHUTTER
 ATTACHMENT SCHEDULE, SEE ATTACHED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-02 Cont ID  
Sent By dpalmer Date 2004-04-17 Time 15:02 Rev Time 1.50
Received By sthyng Date 2003-10-02 Time 17:10 Sent To  
Notes
2003-10-02 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PRODUCT APPROVALS FOR WINDOWS AND
 DOORS WERE SUBMITTED.CHANGE THE
 PERMIT APPLICATION OR THE PLAN TO
 SHOW REFLECT THE SCOPE OF WORK.
  
 3.)WHICH WINDOWS ARE TO BE REPLACED?
 BEDROOMS MUST COMPLY WITH FBC 1005.4.
  
 4.)IMPACT PROTECTION REQUIRED,
 FBC1606.1.4.
  
 5.)SUBMIT TWO COPIES OF ALL REQUIRED
 PRODUCT APPROVALS; WINDOWS, DOORS,
 MULLIONS, IMPACT PROTECTION.
  
 6.)SUBMIT A HURRICANE SHUTTER
 ATTACHMENT SCHEDULE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-07-28 Cont ID  
Sent By dpalmer Date 2004-07-28 Time 19:36 Rev Time 0.25
Received By dpalmer Date 2004-07-28 Time 19:36 Sent To B
Notes
2004-07-28 00:00:00REDLINED ARC FAULT 210.12B 2002 NEC.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-04-17 Cont ID  
Sent By csiegber Date 2004-07-27 Time 15:46 Rev Time 33.00
Received By dpalmer Date 2004-04-17 Time 15:02 Sent To B
Notes
2004-04-17 00:00:00************ UNSAT ******************
  
 1)NOTE: PLANS NOTE EXISTING SERVICE,
 BUT NOTHING SHOWNS? PLEASE SHOW EXISTING
 RISER. PLEASE SHOW A PANEL SCHEDULE W/
 MIN CIRCUITS REQ'D UNDER 2002 NEC.
  
  
 2)NOTE: PLEASE CLARIFY NO DOOR SHOWN
 ON BATH RM? OPEN TO KITCHEN?
  
 ORIG PLANS WERE NOT SUBMITTED??
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-09-05 Cont ID  
Sent By kstevens Date 2004-04-17 Time 07:51 Rev Time 0.50
Received By btrobaug Date 2003-09-05 Time 18:24 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-07-27 Cont ID  
Sent By csiegber Date 2004-07-27 Time 15:46 Rev Time 0.00
Received By csiegber Date 2004-07-27 Time 15:46 Sent To E
Notes
2004-07-27 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-04-08 Cont ID  
Sent By csiegber Date 2004-04-08 Time 08:54 Rev Time 0.00
Received By csiegber Date 2004-04-08 Time 08:54 Sent To M
Notes
2004-04-08 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-04 Time 08:57 Rev Time 0.00
Received By csiegber Date 2003-09-04 Time 08:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-09-02 Cont ID  
Sent By mmclean Date 2003-09-04 Time 08:13 Rev Time 0.00
Received By csiegber Date 2003-09-02 Time 14:55 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-04-13 Cont ID  
Sent By pkrauss Date 2004-04-13 Time 08:12 Rev Time 0.20
Received By pkrauss Date 2004-04-13 Time 07:55 Sent To P
Notes
2004-04-13 00:00:00INSTALLATION OF A WINDOW UNIT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-09-17 Cont ID  
Sent By csiegber Date 2004-04-08 Time 08:54 Rev Time 0.35
Received By pkrauss Date 2003-09-17 Time 09:27 Sent To B
Notes
2003-09-17 00:00:00DENIED:
 INSUFFICIENT INFORMATION FOR REVIEW:
 PLEASE PROVIDE PLANS, ENERGY & MANUAL J
 CALCULATIONS AS PER 2001 FBC CHAPTER 13
 SUB-CHAPTER 6. PROVIDE INFORMATION ON
 A/C EQUIPMENT TO BE INSTALLED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-17 Cont ID  
Sent By kstevens Date 2004-04-17 Time 07:51 Rev Time 0.50
Received By kstevens Date 2004-04-17 Time 07:51 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-11 Cont ID  
Sent By pkrauss Date 2004-04-13 Time 08:23 Rev Time 0.75
Received By kstevens Date 2003-09-11 Time 13:17 Sent To M
Notes
2003-09-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 AMENDMENTS, CHAPTER
 ONE, ADMINISTRATION
 CODE.
  
 1) SHT A-3 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS, NOR DOES IT
 REFLECT THE FLOOR PLAN.
 A) LAV AND KITCHEN SINK SHALL CONNECT
 TO THE STACK, NOT UNDERGROUND AS SHOWN.
 B) WATER CLOSED SHALL NOT BE TRAPPED ON
 THE RISER, THERE IS AN INTEGRAL TRAP IN
 THE FIXTURE. 1002.1
 C) A CLEANOUT IS REQUIRE 4' ABOVE THE
 FLOOR FOR THE WASH MACHINE. 708.10
 D) KITCHEN SINK IS LOCATED TO THE LEFT
 OF THE BATHROOM ON THE FLOOR PLAN AND TO
 THE RIGHT OF THE BATHROOM ON THE SANT.
 RISER DIAGRAM.
 2) SEE RED LINE CORRECTIONS FOR AN EX-
 AMPLE OF A RISER DIAGRAM THAT MEETS CODE
 REQUIREMENTS AND REFLECTS THE FLOOR PLAN
 3) 61G1-16.004(2) FIRM LICENSE NUMBER
 REQUIRED ON TITLE BLOCK FOR EACH SHEET.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-02 Time 14:56 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***