| Plan Review Stops For Permit 03081707 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-10-17 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-17 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-09-08 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-09-08 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | FBC 11-7.2THE ACCESSIBLE CHECKOUT | | | SHALL HAVE A MIN. 36" LONG SECTION OF | | | COUNTER AT MAX. 36" ABOVE FINISHED FLOOR |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-14 |
Time |
20:17 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-14 |
Time |
20:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-08 |
Time |
19:56 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-08 |
Time |
19:55 |
Sent To |
|
|
| Notes |
| 2003-10-08 00:00:00 | *********** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE THAT TITLE BLOCK FOR | | | ENGINEERS AHS BEEN REMOVED AND ARCH IS | | | NOW PRESENT. | | | PLEASE SEE FS 471.003H2AAND SEE | | | FBC 104.4.1.3. ELECTRICAL SYSTEMS OF | | | 277/480V MUST BE DESIGNED, SIGNED,DATED | | | AND SEALED BY AN ENGINEER. ORIG PLANS | | | HAD ENGINEER TITLE BLOCK WHICH LETTER | | | EXPLAINS IT WAS SUBMITTED IN ERROR. | | | PLANS WILL STILL BE REQ'D TO HAVE A | | | TITLE BLOCK FOR ENGINEER WHICH MAY OR | | | MAY NOT INCLUDE A CA #. | | | 61G15-23.002/ 471.025 | | | | | | PLEASE SEE THAT ELECTRICAL COMMENTS | | | SEEM TO BE ADDRESSED. PLANS WILL BE | | | GOING BACK TO BLDG AND MECH PLAN REVIEW | | | DUE TO REVISED B&M SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
12:38 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-09-08 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE COPY OF FAC 61G1-16. | | | 004.PLEASE SEE THAT FIRM'S AA# IS REQ'D | | | ON TITLE BLOCK ALSO. PER FS 481 | | | **ALL SHEETS, NOT ONLY ELECTRICAL. | | | 2)NOTE: PLEASE SEE THAT ALL CONTINUOUS | | | LOADS ARE TO BE SHOWN AT 125%. 215.3/ | | | 230.42 ETC. | | | | | | 3)NOTE: PLEASE SHOW CALCULATIONS FOR | | | TRACK LIGHTING PER 220.12B | | | | | | 4)NOTE: PLEASE SEE CODES REFERENCED ON | | | PLANS, THEY ARE FROM THE 1996 NEC, | | | PLEASE SEE THAT WE ARE NOW UNDER 2002 | | | NEC AND ALL CODES REF. SHOULD CORRELATE. | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW MAIN ALSO. 110.9/215.5 | | | | | | 6)NOTE: PLEASE SHOW GROUNDING ATTACH- | | | -MENT FOR TRANSFORMER PER 250.30 | | | | | | 7)NOTE; PLEASE SEE NEC FOR TRANSFORMER | | | CONNECTIONS, PLAN SHOW EMT TO AND FROM | | | X-FORMER, PLEASE NOTE, THESE ARE TO BE | | | FLEXIBLE CONNECTIONS W/ EQUIPMENT | | | GROUNDING CONDUCTORS. 250.110, 450.10, | | | 300.10 ETC DUE TO VIBRATION OF TRANS- | | | FORMER. | | | | | | 8)NOTE: PLEASE ALSO SHOW LARGEST MOTOR | | | LOAD AT 125%. | | | | | | | | | PLEASE REMOVE ALL OLD VOIDED SHEEST AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. ONE SET OF OLD | | | SHEETS MAY NEED TO BE RESUBMITTED FOR | | | REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-09-05 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-09-05 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2003-09-05 00:00:00 | *************PROVISO******************** | | | WALLS INTERIOR FINISH SHALL BE CLASS "A" | | | OR CLASS "B". | | | ADDITIONAL PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS REMODEL. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2003-10-09 00:00:00 | TO COMM BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
12:38 |
Sent To |
E |
|
| Notes |
| 2003-10-03 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-29 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-29 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2003-08-29 00:00:00 | TO COMM BD #49 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
12:21 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-10-10 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2003-10-10 00:00:00 | PROVISO: | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | REQUIRED AS PER 2001 FBC(M) 606.2.1 AND | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | IN NORMALLY OCCUPIED AREAS AS PER NFPA | | | 90A 4-4.4.3.PLEASE NOTE, DUCT SMOKE | | | DETECTORS SHALL BE INSTALLED IN THE | | | SUPPLY DUCT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-24 |
Time |
10:42 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-09-24 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2003-09-24 00:00:00 | PROVISO: | | | 1.PLEASE NOTE OUTSIDE AIR INTAKE | | | SHALL BE LOCATED A MINIMUM OF 10 FT FROM | | | LOT LINES OR BUILDINGS ON THE SAME LOT. | | | WHERE OPENINGS FROM ON A STREET OR | | | PUBLIC WAY, THE DISTANCE SHALL BE | | | MEASURED TO THE CENTERLINE OF STREET OR | | | WALKWAY. | | | | | | 2.FAN SHUTDOWN REQUIRED WITH NOTIFICAT | | | NOTIFICATION TO ALARM/STROBE AS PER | | | 2001 FBC(M) 606.2.1 & NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-30 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-09-30 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2003-09-30 00:00:00 | NO PLUMBING WORK BEING DONE. MINIMUM | | | FIXTURE FACILITIES PER TABLE 403.1 ARE | | | MET. |
|
|