| Plan Review Stops For Permit 03081548 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-06 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-09-08 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | MUST PAY IMPACT FEES. | | | | | | BERTHA SHUTTER NOA ILLEGIBLE. | | | | | | CLOPAY DOOR MISSING TEST REPORT OR NOA. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-06 |
Time |
10:21 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-06 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2003-10-06 00:00:00 | SENT TO HP TO VERUFY PREVIOUS NOTES AND | | | IMPACT FEES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:36 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-09-08 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | *************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE PLANS, ALL CODES AND | | | NOTES REFERENCE TO THE 99 NEC. | | | PLEASE NOTE WE ARE NOW UNDER THE 2002 | | | NEC AND ADJUST ARTS ACCORD. | | | | | | 2)NOTE: PLEASE CORRELATE RISER AND PANEL | | | SCHEDULES FOR A/C COND OCP. RISER SHOWS | | | 40A OCP AND PANELS SHOW 30A? | | | | | | 3)NOTE: PLANS MENTION ALL AS-BUILTS AND | | | REVISIONS ARE TO DONE BEFORE FINAL, | | | PLEASE NOTE, THESE ARE NOW REQ'D BEFORE | | | ROUGH****. | | | | | | 4)NOTE: PLEASE SUBMIT/SHOW AIC RATINGS | | | FOR MAINS AND PANELS. 110.9/215.5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-30 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-09-30 00:00:00 | NO ENG REVIEW REQUIRED PER LUIS MARTINEZ |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-04 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-04 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2003-09-04 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED | | | PRIOR TO, DURING AND AFTER CONSTRUCTION. | | | | | | 2) BUILDING ADDRESSES ARE REQUIRED. | | | A MINIMUM OF THREE INCH NUMBERS ARE | | | REQUIRED. | | | | | | 3) PORTABLE FIRE EXTINGUISHERS ARE | | | REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-15 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2003-10-15 00:00:00 | TO HP DESK/RESUB PER NOTES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2003-10-02 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-02 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-02 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | TO COMM BD #59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-09-02 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-26 |
Time |
14:39 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-29 |
Time |
10:45 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-09-29 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | PROVISO: | | | PLEASE NOTE, REVISION TO THE 2001 | | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM ITS SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-29 |
Time |
09:32 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-09-29 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-26 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-09-02 00:00:00 | 9/2/03 PASS ZONING PER GRACE JOYCE MM |
|
|