Plan Review Details - Permit 03081461
Plan Review Stops For Permit 03081461
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-25 Cont ID  
Sent By jgomez Date 2003-09-25 Time 09:44 Rev Time 3.00
Received By jgomez Date 2003-09-25 Time 09:44 Sent To PC
Notes
2003-09-25 00:00:00BUILDING CHECKLIST:
 1-REVISE/UPDATE NOTES ON SHEET SP. NEED
 TO REFERENCE UPDATE CODES. SEE PLANS
 FOR REDLINED COMMENTS.
 2-DOORS AND WINDOWS CALCULATED DESIGN
 PRESSURES ARE NOT LEGIBLE.
 3-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING BACK STAMPED DRAWINGS AND PAID
 RECEIPT. (AFTER DWGS ARE REVISED).
 4-NEED RECORDED NOTICE OF COMMENCEMENT.
 5-REVISE DOOR AND WINDOW BUCK DETAILS.
 SEE SECTION 1707.4.4.2 FBC 2001 FOR
 PROPER ATTACHMENT.
 **ALSO, CLARIFY WHICH DETAILS/SPECS TO
 BE USED. THOSE ON SHEET A-5 OR S-2?
 6-SPECIFY WINDOW SIZE FOR OFFICE/GUEST
 BEDROOM TO VERIFY FOR EGRESS SIZES
 REQUIRED BY SEC. 1005.4 FBC 2001.
 **NOTE: KEEP IN MIND THAT CASEMENT WIND.
 NEED CENTER MULLION, THEREFORE IT WILL
 REDUCE THE CLEAR WIDTH.
 7-PROVIDE 2 COPIES OF PRODUCT APPROVAL:
 A)METAL ROOF SYSTEM. (PRODUCT APPROVAL
 SUBMITTED IS FOR SHINGLES).
 B)FLAT ROOF SYSTEM.
 C)FRENCH DOOR TO MATCH GARAGE DOOR.
 D)GARAGE DOOR.
 E)CASEMENT WINDOWS WITH LEGIBLE DWGS.
 F)FRENCH DOORS WITH LEGIBLE DRAWINGS.
  
 8-PROVIDE ATTIC ACCESS AT GARAGE WING.
 SEC. 2309.6 FBC 2001.
 9-PROVIDE COMPLETE SECTION/DETAIL AND
 FASTENER SPECS FOR TRELLIS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 10-PROVIDE ROOF FRAMING PLAN SPECIFYING
 CALCULATED UPLIFT LOADS AND KEYING
 TRUSS ANCHOR SCHEDULE. SECTION 1606
 FBC 2001 AND 104.2.1.2 CITY AMENDMENTS
 **ALSO, SHOW ALL BEAMS. EG: FRONT PORCH.
 11-PROVIDE COMPLETE DETAIL/SPECS FOR
 CEILING INSTALLATION AT FRONT PORCH
 AND SOFFITS.
 SEE ASTM C-926 AND ASTM C-1063.
 SECTION 2504.2 FBC 2001.
 12-PROVIDE COMPLETE INFORMATION AT ENTRY
 STOOP SECTION. SPECIFY STRUCTURAL
 MEMBERS AND FASTENERS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 13-SEE COMMENTS ON SHEET A-5 NOTES AND
 REVISE AS REQUIRED. PLEASE RETURN THE
 REVIEWED SET OF DRAWINGS TO EXPEDITE
 THE REVIEW PROCESS.
 14-PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES.
 SEE SECTION 2305 FBC 2001.
 15-UPDATE TRUSS ANCHOR SCHEDULE TO
 COMPLY WITH SEC. 1609.4.3 FBC 2001,
 WHICH DOESN'T ALLOW THE STEEL STRESS
 TO BE INCREASED.
 **NOTE: IF USING SIMPSON CONNECTORS,
 THEN, USE HIGH WIND-RESISTANT CONST.
 CATALOGUE WHICH WAS UPDATED TO COMPLY
 WITH THIS SECTION OF THE CODE.
 16-CLARIFY WHAT WINDOW/DOOR BUCK DETAIL
 SPECS ARE TO BE USED. THOSE SHOWN ON
 SHEET A-5 OR S-2?.
 17-UPDATE NOTES ON SHEET A-1. SEE
 REDLINED COMMENTS.
 18-CLARIFY ROOF SHEATHING NOTES. THERE
 ARE DIFFERENT SPECS THROUGHOUT DWGS.
 SEE DWGS A-2, A-3, A-4 AND S-2.
 19-UPDATE/REVISE INFORMATION ON SHEET
 S-2. SEE COMMENTS AND RETURN OLD SET
 AFTER CORECTIONS ARE DONE TO THE
 ORIGINAL CAD DRAWINGS TO EXPEDITE THE
 REVIEW PROCESS.
 20-PROVIDE COMPLETE SPECS FOR ENTRY
 PORCH. SEE COMMENTS ON SHEET S-1.
 21-ARCHITECT TO HAVE ALL HIS INFORMATION
 ON LOGO AS REQUIRED BY CHAPTER 481
 FLORIDA STATUTES.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-09-04 Cont ID  
Sent By dbaxter Date 2003-09-03 Time 16:18 Rev Time 0.50
Received By btrobaug Date 2003-09-04 Time 12:22 Sent To G
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-03 Cont ID  
Sent By dbaxter Date 2003-09-03 Time 16:18 Rev Time 0.00
Received By dbaxter Date 2003-09-03 Time 16:18 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-25 Cont ID  
Sent By mmclean Date 2003-09-03 Time 15:04 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 13:50 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-15 Cont ID  
Sent By kstevens Date 2003-09-06 Time 16:57 Rev Time 0.33
Received By pkrauss Date 2003-09-15 Time 08:13 Sent To P
Notes
2003-09-15 00:00:00PROVISO:
 PLEASE NOTE, REVISION TO THE 2001
 FBC(M) 601.4, EFFECTIVE JUNE 30,2003:
  
 BALANCED AIR RETURN - RETURN/TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM ITS SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-09-06 Cont ID  
Sent By pkrauss Date 2003-09-15 Time 08:13 Rev Time 0.50
Received By kstevens Date 2003-09-06 Time 16:57 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-08-25 Time 13:50 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
2003-09-03 00:00:008/29/03 PASS ZONING PER SHIRLEY GRAHAM
 NOTE: POOL NOT APPROVED ON THIS PERMIT
 MUST PULL SEPARATE PERMIT FOR POOL MM