Plan Review Details - Permit 03081449
Plan Review Stops For Permit 03081449
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-07-12 Cont ID  
Sent By jleech Date 2003-10-02 Time 20:07 Rev Time 0.25
Received By mjacobs Date 2004-07-12 Time 11:26 Sent To  
Notes
2004-07-12 00:00:00WINDOW SUBMITTALS OK

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-08-13 Cont ID  
Sent By btrobaug Date 2004-08-12 Time 11:44 Rev Time 0.75
Received By btrobaug Date 2004-08-12 Time 11:07 Sent To  
Notes
2004-08-12 00:00:00 
 THE RISER AND THE NUMBER OF PANELS ON
 THE PLAN. PLEASE CORRELATE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-08-04 Cont ID  
Sent By csiegber Date 2004-08-09 Time 10:50 Rev Time 0.50
Received By btrobaug Date 2004-08-04 Time 12:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-08-03 Cont ID  
Sent By dpalmer Date 2004-08-03 Time 11:20 Rev Time 0.25
Received By dpalmer Date 2004-08-03 Time 11:18 Sent To  
Notes
2004-08-03 00:00:00************ UNSAT ****************
  
 1)NOTE: PLEASE SEE MISSING LICENSE #'S
 ON TITLE BLOCK. FAC 61G1-16.004
 HAND DRAWN ON PLANS BY CONT, HOWEVER
 PLANS NEED CORRECTION FOR ELEC.
  
 2)NOTE: PLEASE SEE MISSING RECEPT(S)
 PER 210.52
 PLEASE SEE MISSING W/IN 3' OF SINKS
 PER 210.52D. BATH #2/ MAST.
  
 3)NOTE:: PLEASE SEE RECEPT IN LAUNDRY
 RM TO BE GFI. 210.8 LOCAL AMENDMENTS
 W/IN 6' OF SINK.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-29 Cont ID  
Sent By csiegber Date 2004-07-26 Time 16:49 Rev Time 0.33
Received By dpalmer Date 2003-08-29 Time 07:44 Sent To M
Notes
2003-08-29 00:00:00************ NOTES REDLINED ******
  
 PLEASE SEE MISSING EQUIPMENT GRND FROM
 MAIN TO PANEL, SIZE PER 250.122
 250.24/250.110
  
 PLEASE SEE RANGE SHOWN W/ 2P30A? SHOULD
 BE 50A.
  
 PLEASE MOVE ADDTIONAL SD OUTSIDE MASTER
 BEDROOM. NFPA-72 8-1.4.2
  
 PLEASE SEE THAT MAIN IS NOT SHOWN ON
 PLANS AS SHOWN ON RISER.
  
  
 REVISE PLANS BEFORE ROUGH.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-08-09 Cont ID  
Sent By csiegber Date 2004-08-09 Time 10:50 Rev Time 0.00
Received By csiegber Date 2004-08-09 Time 10:50 Sent To E
Notes
2004-08-09 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-26 Cont ID  
Sent By csiegber Date 2004-07-26 Time 16:49 Rev Time 0.00
Received By csiegber Date 2004-07-26 Time 16:49 Sent To E
Notes
2004-07-26 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-02-17 Time 16:17 Rev Time 0.00
Received By csiegber Date 2004-02-17 Time 16:17 Sent To M
Notes
2004-02-17 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-24 Cont ID  
Sent By csiegber Date 2003-09-24 Time 15:17 Rev Time 0.00
Received By csiegber Date 2003-09-24 Time 15:17 Sent To P
Notes
2003-09-24 00:00:00TO KS BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 16:42 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 16:42 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-25 Cont ID  
Sent By mmclean Date 2003-08-25 Time 16:22 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 13:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-01 Cont ID  
Sent By pkrauss Date 2004-03-01 Time 12:31 Rev Time 0.25
Received By pkrauss Date 2004-03-01 Time 12:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-02 Cont ID  
Sent By csiegber Date 2004-02-17 Time 16:17 Rev Time 0.25
Received By pkrauss Date 2003-09-02 Time 08:00 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By jleech Date 2003-10-02 Time 20:07 Rev Time 0.33
Received By jleech Date 2003-10-02 Time 20:06 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-24 Time 15:17 Rev Time 0.33
Received By kstevens Date 2003-09-03 Time 10:28 Sent To B
Notes
2003-09-03 00:00:00DENIED
 REFERENCE: FBC-2001 AMENDMENTS, CHAPTER
 ONE, ADMIN. CODE
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. SUBMIT A RISER
 DIAGRAM THAT REFLECTS THE FLOOR PLAN AND
 REFLECTS ACTUAL INSTALLATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 13:52 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved