| Plan Review Stops For Permit 03081449 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-10-02 |
Time |
20:07 |
Rev Time |
0.25 |
| Received By |
mjacobs |
Date |
2004-07-12 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | WINDOW SUBMITTALS OK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-12 |
Time |
11:44 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-08-12 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | | | | THE RISER AND THE NUMBER OF PANELS ON | | | THE PLAN. PLEASE CORRELATE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-09 |
Time |
10:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-04 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
11:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2004-08-03 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE MISSING LICENSE #'S | | | ON TITLE BLOCK. FAC 61G1-16.004 | | | HAND DRAWN ON PLANS BY CONT, HOWEVER | | | PLANS NEED CORRECTION FOR ELEC. | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT(S) | | | PER 210.52 | | | PLEASE SEE MISSING W/IN 3' OF SINKS | | | PER 210.52D. BATH #2/ MAST. | | | | | | 3)NOTE:: PLEASE SEE RECEPT IN LAUNDRY | | | RM TO BE GFI. 210.8 LOCAL AMENDMENTS | | | W/IN 6' OF SINK. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
16:49 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-29 |
Time |
07:44 |
Sent To |
M |
|
| Notes |
| 2003-08-29 00:00:00 | ************ NOTES REDLINED ****** | | | | | | PLEASE SEE MISSING EQUIPMENT GRND FROM | | | MAIN TO PANEL, SIZE PER 250.122 | | | 250.24/250.110 | | | | | | PLEASE SEE RANGE SHOWN W/ 2P30A? SHOULD | | | BE 50A. | | | | | | PLEASE MOVE ADDTIONAL SD OUTSIDE MASTER | | | BEDROOM. NFPA-72 8-1.4.2 | | | | | | PLEASE SEE THAT MAIN IS NOT SHOWN ON | | | PLANS AS SHOWN ON RISER. | | | | | | | | | REVISE PLANS BEFORE ROUGH. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-09 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-09 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
| 2004-08-09 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-26 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-26 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2004-07-26 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-17 |
Time |
16:17 |
Sent To |
M |
|
| Notes |
| 2004-02-17 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-24 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-24 |
Time |
15:17 |
Sent To |
P |
|
| Notes |
| 2003-09-24 00:00:00 | TO KS BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-25 |
Time |
16:42 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-25 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-25 |
Time |
13:52 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-01 |
Time |
12:31 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-03-01 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
16:17 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-09-02 |
Time |
08:00 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-10-02 |
Time |
20:07 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-10-02 |
Time |
20:06 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-24 |
Time |
15:17 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-09-03 |
Time |
10:28 |
Sent To |
B |
|
| Notes |
| 2003-09-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 AMENDMENTS, CHAPTER | | | ONE, ADMIN. CODE | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | | FLECT THE FLOOR PLAN. SUBMIT A RISER | | | DIAGRAM THAT REFLECTS THE FLOOR PLAN AND | | | REFLECTS ACTUAL INSTALLATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|