Plan Review Details - Permit 03081345
Plan Review Stops For Permit 03081345
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-01-28 Cont ID  
Sent By rmcdouga Date 2004-01-28 Time 13:40 Rev Time 1.00
Received By rmcdouga Date 2004-01-28 Time 13:40 Sent To  
Notes
2004-01-28 00:00:00REVISION TO SHEET A7 AND STAIR SHOP
 DRAWINGS ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-14 Cont ID  
Sent By kstevens Date 2004-01-28 Time 10:45 Rev Time 2.00
Received By rmcdouga Date 2003-10-14 Time 11:27 Sent To  
Notes
2003-10-14 00:00:00PROVISO
  
 1) SUBMIT (2) COPIES OF A KEY PLAN AND
 INSTALLATION SCHEDULE FOR THE HURRICANE
 PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-08 Cont ID  
Sent By kstevens Date 2003-08-28 Time 13:13 Rev Time 2.50
Received By rmcdouga Date 2003-09-08 Time 08:50 Sent To  
Notes
2003-09-08 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT A SIGNED AND SEALED COPY OF
 THE SOIL BORING TEST REPORT AS REQUIRED
 BY FBC 1804.2.2.
  
 4) SPECIFY THE FASTENERS AND EMBED DEPTH
 FOR THE TRUSS BUCKETS (ST) ON A7.
  
 5) SPECIFY THE FASTENERS AND EMBED DEPTH
 FOR THE STEEL COLUMN BASES ON A7.
  
 6) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 3/4" DIA. WEDGE ANCHORS IN DETAIL 1 ON
 A8.
  
 7) THE ANCHOR SCHEDULE ON A7 SPECIFIES
 (9) 10D X 1-1/2" NAILS FOR THE TA9
 CONNECTORS(USP TA20R). THIS IS INCORRECT
 THE 2003 USP CATALOG REQUIRES (10) 10D X
 1-1/2" NAILS TO ATTAIN THE LISTED VALUES
 PLEASE CORRECT.
  
 8)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 9) THE SITE SPECIFIC PRODUCT APPROVAL
 SUBMITTED IS FOR INSWING DOORS AND IS
 LIMITED TO A MAXIMUM HEIGHT OF 6'8". THE
 GLAZED DOUBLE ENTRY DOORS ARE OUTSWING
 AND ARE 8' IN HEIGHT. THE FORM IS ALSO
 REQUIRED TO BE SIGNED BY THE DESIGNER OF
 RECORD.
  
 10) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR ROOFING MATERIALS.
  
 11) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SUBMIT A
 SIGNED AND SEALED LETTER FROM KNEZEVICH
 AND ASSOC. CLARIFYING THE USE OF CALK-IN
 ANCHORS IN CONCRETE BLOCK.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-08-06 Cont ID  
Sent By btrobaug Date 2004-08-06 Time 07:34 Rev Time 0.50
Received By btrobaug Date 2004-08-06 Time 07:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-13 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:23 Rev Time 0.50
Received By btrobaug Date 2003-11-13 Time 10:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-11-10 Time 08:36 Rev Time 0.50
Received By btrobaug Date 2003-08-27 Time 13:48 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:23 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 08:23 Sent To E
Notes
2004-07-29 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-10 Cont ID  
Sent By csiegber Date 2003-11-10 Time 08:36 Rev Time 0.00
Received By csiegber Date 2003-11-10 Time 08:36 Sent To E
Notes
2003-11-10 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-06 Time 09:57 Rev Time 0.00
Received By csiegber Date 2003-10-06 Time 09:57 Sent To P
Notes
2003-10-06 00:00:00TO KS BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 16:31 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 16:31 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-25 Cont ID  
Sent By mmclean Date 2003-08-25 Time 12:02 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 08:02 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 14:25 Rev Time 0.25
Received By pkrauss Date 2003-08-28 Time 07:21 Sent To P
Notes
2003-08-28 00:00:00PROVISO:
  
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-01-28 Cont ID  
Sent By kstevens Date 2004-01-28 Time 10:45 Rev Time 0.50
Received By kstevens Date 2004-01-28 Time 10:45 Sent To B
Notes
2004-01-28 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-10-06 Cont ID  
Sent By jleech Date 2003-10-06 Time 19:51 Rev Time 0.25
Received By jleech Date 2003-10-06 Time 19:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-08-28 Cont ID  
Sent By csiegber Date 2003-10-06 Time 09:57 Rev Time 0.33
Received By kstevens Date 2003-08-28 Time 13:01 Sent To B
Notes
2003-08-28 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 A) POWDER ROOM ON RISER SHOWS A SHOWER.
 NONE SHOWN ON FLOOR PLAN.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:02 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***