Plan Review Details - Permit 03081342
Plan Review Stops For Permit 03081342
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-14 Cont ID  
Sent By btrobaug Date 2003-10-14 Time 09:21 Rev Time 2.00
Received By rmcdouga Date 2003-10-14 Time 08:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-10-06 Time 09:39 Rev Time 2.50
Received By rmcdouga Date 2003-09-04 Time 07:41 Sent To  
Notes
2003-09-04 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT A SIGNED AND SEALED COPY OF
 THE SOIL BORING TEST REPORT AS REQUIRED
 BY FBC 1804.2.2.
  
 4) THE WALLS OF THE BREAKFAST ROOM AND
 THE FAMILY ROOM AT THE RIGHT ELEVATION
 APPEAR TO EXCEED THE PERCENTAGE OF WALL
 AREA THAT IS ALLOWED AS OPENINGS BY FBC
 TABLE 600. THE WALL 18.34' FROM THE
 PROPERTY LINE IS ALLOWED 40% OF THE WALL
 AREA AS OPENINGS AND THE FAMILY ROOM
 WALL AT 26.67' FROM THE PROPERTY LINE IS
 ALLOWED 60%. SUBMIT THE TABLE 600
 CALCULATIONS FOR THESE ELEVATIONS.
  
 5) THE 16' X 7' OVERHEAD GARAGE DOOR IS
 NOT LISTED ON THE WIND LOAD SCHEDULE ON
 A1.
  
 6) THE SITE SPECIFIC ENGINEERING FOR THE
 OUTSWING GLAZED DOOR DOES NOT MEET THE
 -60.4 PSF WIND LOAD PRESSURE REQUIRED BY
 THE WIND LOAD SCHEDULE ON SHEET A1.
 THE SITE SPECIFIC FORM IS NOT SIGNED BY
 THE DESIGNER OF RECORD.
  
 7) SUBMIT A SIGNED AND SEALED LETTER
 FROM THE STORM PANEL ENGINEER STATING
 THAT CALK-IN ANCHORS CAN BE USED IN THE
 CONCRETE BLOCK. SPECIFY THE PSI OF THE
 BLOCK TO ACHIEVE THE PRESSURES AND
 SPACINGS INDICATED.
  
 8)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR THE ROOFING MATERIAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-11-24 Cont ID  
Sent By btrobaug Date 2003-11-24 Time 09:49 Rev Time 0.50
Received By btrobaug Date 2003-11-24 Time 09:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:24 Rev Time 0.50
Received By btrobaug Date 2003-10-14 Time 08:55 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-08-25 Time 16:34 Rev Time 0.50
Received By btrobaug Date 2003-08-27 Time 13:25 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:24 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 15:24 Sent To E
Notes
2003-11-21 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-06 Time 09:39 Rev Time 0.00
Received By csiegber Date 2003-10-06 Time 09:39 Sent To B
Notes
2003-10-06 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 16:34 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 16:34 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-25 Cont ID  
Sent By mmclean Date 2003-08-25 Time 12:04 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 08:04 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 13:47 Rev Time 0.25
Received By pkrauss Date 2003-08-28 Time 07:12 Sent To P
Notes
2003-08-28 00:00:00PROVISO:
  
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By pkrauss Date 2003-08-28 Time 07:12 Rev Time 0.33
Received By kstevens Date 2003-08-28 Time 13:34 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 08:04 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***