| Plan Review Stops For Permit 03081255 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-28 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-28 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-09-02 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-09-02 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-15 |
Time |
07:10 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-15 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-29 |
Time |
07:15 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-08-29 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2003-08-29 00:00:00 | ******** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE THIRD SET, ELECTRICAL | | | SHEETS MISSING. | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT FOR | | | SHOW WINDOWS. 210.62 | | | | | | 3)NOTE: PLEASE SEE 600.5 FOR MISSING | | | SIGN CIRCUIT. | | | | | | PLEASE SEE THAT NOTE 2,3 CAN BE REDLINED | | | PLEASE COMPLETE SET THREE. | | | PLEASE SEE OTHER REVIEWS THAT MAY HAVE | | | AN AFFECT ON ELEC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-17 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-17 |
Time |
17:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-04 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-04 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2003-09-04 00:00:00 | 1) FIRE ALARM NOTES # 17 IS INCORRECT. | | | ACTIVATION OF DUCT SMOKE DETECTORS | | | SHALL CAUSE AN ALARM NOT A SUPERVISORY | | | SIGNAL. | | | | | | 2) FIRE ALARM NOTES # 19 IS INCORRECT. | | | FIRE ALARM CIRCUITS SHALL BE CLASS A, | | | STYLE D NOT CLASS B, STYLE C. | | | | | | 3) SEPARATE PLANS AND PERMITS FOR | | | FIRE ALARM AND FIRE SPRINKLER SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2003-10-09 00:00:00 | TO COMM BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-21 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-21 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | TO COMM BD #55 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-24 |
Time |
06:55 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-09-24 |
Time |
06:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
14:14 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-25 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-23 |
Time |
11:04 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-09-23 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2003-09-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) PER TABLER 403.1 A DRINKING FOUNTAIN | | | IS REQUIRED. ALSO SEE SEC 410.1 | | | 2) SHT P0.1 DOMESTIC WATER ISOMETRIC, | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF. INSTALL. INSTRUCTIONS. (SEE | | | PLUMBING NOTES #13). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|