Plan Review Details - Permit 03081255
Plan Review Stops For Permit 03081255
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-28 Cont ID  
Sent By hpiskura Date 2003-10-28 Time 15:47 Rev Time 0.00
Received By hpiskura Date 2003-10-28 Time 15:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-09-02 Cont ID  
Sent By hpiskura Date 2003-09-02 Time 10:13 Rev Time 0.00
Received By hpiskura Date 2003-09-02 Time 10:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-15 Cont ID  
Sent By dpalmer Date 2003-10-15 Time 07:10 Rev Time 0.33
Received By dpalmer Date 2003-10-15 Time 07:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-08-29 Cont ID  
Sent By dpalmer Date 2003-08-29 Time 07:15 Rev Time 0.50
Received By dpalmer Date 2003-08-29 Time 07:15 Sent To  
Notes
2003-08-29 00:00:00******** UNSAT **************
  
 1)NOTE: PLEASE SEE THIRD SET, ELECTRICAL
 SHEETS MISSING.
  
 2)NOTE: PLEASE SEE MISSING RECEPT FOR
 SHOW WINDOWS. 210.62
  
 3)NOTE: PLEASE SEE 600.5 FOR MISSING
 SIGN CIRCUIT.
  
 PLEASE SEE THAT NOTE 2,3 CAN BE REDLINED
 PLEASE COMPLETE SET THREE.
 PLEASE SEE OTHER REVIEWS THAT MAY HAVE
 AN AFFECT ON ELEC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-10-17 Cont ID  
Sent By mcarsill Date 2003-10-17 Time 17:46 Rev Time 0.00
Received By mcarsill Date 2003-10-17 Time 17:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-09-04 Cont ID  
Sent By mcarsill Date 2003-09-04 Time 07:52 Rev Time 0.00
Received By mcarsill Date 2003-09-04 Time 07:51 Sent To  
Notes
2003-09-04 00:00:001) FIRE ALARM NOTES # 17 IS INCORRECT.
 ACTIVATION OF DUCT SMOKE DETECTORS
 SHALL CAUSE AN ALARM NOT A SUPERVISORY
 SIGNAL.
  
 2) FIRE ALARM NOTES # 19 IS INCORRECT.
 FIRE ALARM CIRCUITS SHALL BE CLASS A,
 STYLE D NOT CLASS B, STYLE C.
  
 3) SEPARATE PLANS AND PERMITS FOR
 FIRE ALARM AND FIRE SPRINKLER SYSTEM.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-09 Time 16:22 Rev Time 0.00
Received By csiegber Date 2003-10-09 Time 16:22 Sent To  
Notes
2003-10-09 00:00:00TO COMM BD#53

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-21 Cont ID  
Sent By csiegber Date 2003-08-21 Time 15:49 Rev Time 0.00
Received By csiegber Date 2003-08-21 Time 15:49 Sent To  
Notes
2003-08-21 00:00:00TO COMM BD #55

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-24 Cont ID  
Sent By pkrauss Date 2003-09-24 Time 06:55 Rev Time 0.40
Received By pkrauss Date 2003-09-24 Time 06:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-10-25 Cont ID  
Sent By kstevens Date 2003-10-25 Time 14:14 Rev Time 0.33
Received By kstevens Date 2003-10-25 Time 14:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-23 Cont ID  
Sent By kstevens Date 2003-09-23 Time 11:04 Rev Time 1.00
Received By kstevens Date 2003-09-23 Time 11:03 Sent To  
Notes
2003-09-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) PER TABLER 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE SEC 410.1
 2) SHT P0.1 DOMESTIC WATER ISOMETRIC,
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURE IN AN "EFFECTIVE RANGE"
 NOT IN THE CEILING AS SHOWN. PDI-WH 201
 AND MANUF. INSTALL. INSTRUCTIONS. (SEE
 PLUMBING NOTES #13).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]