| Plan Review Stops For Permit 03081252 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-09-03 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-09-03 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2003-09-03 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | THE CLEARANCES AND HEIGHTS AT THE WATER | | | COOLER SHALL COMPLY WITH FBC 11-4.15 FOR | | | ACCESSIBILITY. | | | | | | --PROVISO-- | | | SHEET A-2 HAS BEEN REDLINED. THE CENTER- | | | LINE OF THE W.C. PAN SHALL BE 18" FROM | | | THE ADJACENT WALL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-18 |
Time |
16:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-18 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:39 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-08-29 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2003-08-29 00:00:00 | ******* NOTES REDLINED ********** | | | | | | SIGN CIRCUIT PER 600.5 | | | SHOW WINDOW RECEPTS 210.62 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-10-20 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-10-20 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | PLANS WERE APPROVED AND PASSED BY MIKE | | | CARSILLO ON 10-17-03 | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-09-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-05 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-05 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2003-09-05 00:00:00 | 1) FIRE ALARM NOTES # 19 IS INCORRECT. | | | FIRE ALARM CIRCUITS SHALL BE CLASS A, | | | STYLE D. | | | | | | 2) FIRE ALARM NOTES # 17 IS INCORRECT. | | | DUCT SMOKE DETECTORS WHEN ACTIVATED | | | SHALL ACTIVATE THE BUILDING'S FIRE | | | ALARM SYSTEM NOT A SUPERVISORY | | | SIGNAL. | | | | | | 3) SEPARATE PLANS AND PERMITS FOR | | | FIRE SPRINKLER AND FIRE ALARM SYSTEM | | | REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
16:39 |
Sent To |
E |
|
| Notes |
| 2003-12-17 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2003-10-09 00:00:00 | TO COMM BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-21 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-21 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | TO COMM BD #47 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-14 |
Time |
08:01 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-10-14 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-09-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-09-22 |
Time |
19:35 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2003-09-22 |
Time |
19:35 |
Sent To |
|
|
| Notes |
| 2003-09-22 00:00:00 | PLAN DENIED | | | 1) REFER TO SECTION 601.4 BALANCED | | | RETURN AIR | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-23 |
Time |
10:09 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-09-23 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2003-09-23 00:00:00 | PASSED/PROVISO - WATER HAMMER ARRESTORS | | | TO BE LOCATED NEAR FIXTURE, NOT IN | | | CEILING. |
|
|