| Plan Review Stops For Permit 03081163 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-06-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-01 |
Time |
17:04 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-06-01 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2004-06-01 00:00:00 | REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-04 |
Time |
12:30 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-05-04 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LIST.ALL CORRECTIONS | | | STILL APPLY. | | | | | | 2.)REGARDING REVIEW OF CERTIFICATE | | | OF COMPLIANCE FOR FLEMING DOOR: | | | THE PAPERWORK SUBMITTED IS NOT A TEST | | | REPORT (ONLY REFERS TO TEST REPORTS) | | | AS REQUIRED BY FBC1703.ALSO THE TEST | | | STANDARDS USED ARE NOT THE STANDARDS | | | REFERRED TO IN FBC CHAPTER 35. | | | | | | 3.)NOTE THAT THIS DOOR WAS TESTED TO | | | AN IMPACT STANDARD.MY UNDERSTANDING | | | IS THAT ONE DOOR WAS IMPACT, THE OTHER | | | DOOR WAS NON IMPACT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-04-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-27 |
Time |
11:27 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-04-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2004-04-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | SUBMITTED WERE: | | | 2 SETS OF PLANS DATED 4/5/04 | | | TWO STORM PANEL SBCCI REPORTS | | | TWO COPIES OF NOA 02-0523.06, INCOMPLE | | | TWO COPIES OF INCOMPLETE NOA02-0523.07 | | | AND DATA SHEETS | | | TWO COPIES OF LETTER DATED 4/19 | | | | | | 1.)THE ILLEGIBLE PARTIAL NOA | | | SUBMITTED 02-0523.07 IS FOR AN INSWING | | | DOOR.PER CONTRACTOR'S REP, ONLY | | | OUTSWING DOORS ARE TO BE INSTALLED. | | | EITHER SUBMIT THE CORRECT PRODUCT | | | APPROVAL OR REVISE THE PLAN.ALSO THIS | | | DOOR IS NOT FOR AREAS REQUIRING WATER | | | INFILTRATION.ALSO THIS DOOR IS NOT | | | A GLAZED DOOR.ALSO THE PRODUCT | | | APPROVAL DOES NOT INCLUDE SIDELITES. | | | HAVE THE DOOR PRODUCT APPROVALS | | | APPROVED BY HISTORIC BEFORE RESUBMITTAL | | | TO AVOID CONFUSION. | | | THIS COMMENT IS THE SAME AS THE PREVIOUS | | | LIST, ITEMS 2, 3, 4, 5, AND 6. | | | | | | 2.)THE OTHER NOA SUBMITTED IS ALSO | | | A PARTIAL ILLEGIBLE TEST REPORT.THIS | | | IS THE SAME ONE SUBMITTED PREVIOUSLY | | | AND DOES NOT INCLUDE SIDELITES AND IS | | | RESTRICTED TO 100 SQUARE INCHES OF | | | LEXAN, NOT FULLY GLAZED AS DESCRIBED. | | | | | | 3.)THE LETTER SENT INDICATES THAT A | | | SHUTTER WILL BE INSTALLED OVER BOTH | | | DOORS.ONE IS NOT TO HAVE A SHUTTER | | | TO COMPLY WITH FBC1005.4.5 AS DISCUSSED. | | | THE LETTER STATES THAT ROLL DOWN | | | SHUTTERS WILL BE INSTALLED.PRODUCT | | | APPROVALS FOR STORM SHUTTERS ONLY HAVE | | | BEEN SUBMITTED. | | | | | | 4.)I HAVE SPOKEN WITH THE | | | TECHNICAL REPRESENTATIVE FROM FLEMING | | | DOORS TO ATTEMPT TO ASSIST YOU IN | | | OBTAINING THE CORRECT PAPERWORK FOR | | | THE PRODUCT YOU WOULD LIKE TO INSTALL. | | | THE TEST REPORT FOR THE DOOR YOU HAVE | | | DESCRIBED TO BE IS A UL REPORT (FRENCH | | | DOORS WITH SIDELITES).FOR THE FULLY | | | GLAZED SINGLE DOOR, THE TEST REPORT WILL | | | BE AVAILABLE MID MAY.ADDRESS. | | | | | | 5.)WHEN SUBMITTING THE PLANS WITH THE | | | TEST REPORT, SUBMIT AS A SUBMITTAL (NO | | | FEE), NOT A REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
12:12 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-04-12 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2004-04-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)ONE MEANS OF ESCAPE DURING A | | | HURRICANE IS TO BE PROVIDED, FBC1005.4.5 | | | THIS MEANS OF ESCAPE CANNOT BE THROUGH | | | A GARAGE.BASED ON A CONVERSATION WITH | | | THE CONTRACTOR, ALL EXTERIOR DOORS ARE | | | BEING REPLACE WITH GLAZED DOORS | | | REQUIRING IMPACT PROTECTION. | | | | | | 2.)THE PRODUCT APPROVAL SUBMITTED | | | DOES NOT INCLUDE THE SIDELITES OR | | | MULLIONS.THE PRODUCT APPROVAL FOR THE | | | OUTSWING DOOR IS LIMITED TO 100 SQ IN | | | OF LEXAN (NOT A FULLY GLAZED DOOR), AND | | | SIDELITES AND MULLIONS ARE NOT A PART | | | OF THE APPROVAL. | | | | | | 3.)IN MY CONVERSATION WITH JAY | | | LAWRENCE, HE INDICATED THAT THE DOORS | | | ARRIVE WITHOUT GLASS AND WILL BE GLAZED | | | ON SITE.THIS DESCRIPTION DOES NOT | | | MATCH THE PRODUCT APPROVALS SUBMITTED. | | | | | | 4.)THE PRODUCT APPROVALS ARE | | | ILLEGIBLE.ALSO, TWO COPIES ARE NEEDED | | | OF THE SAME PRODUCT APPROVAL.ONE WAS | | | FOR INSWING, ONE WAS OUTSWING.THE | | | PLAN SHOWS OUTSWING ONLY.THE PRODUCT | | | APPROVALS ARE TO BE LEGIBLE AND ON | | | GOOD QUALITY PAPER.ONE WAS SUBMITTED | | | ON THERMAL FAX PAPER. | | | | | | 5.)FYI, THE INSWING DOOR IS NOT FOR | | | USE WHERE WATER INFILTRATION | | | REQUIREMENTS ARE NEEDED.HOWEVER, | | | APPARENTLY THIS PRODUCT APPROVAL WAS | | | SUBMITTED IN ERROR. | | | | | | 6.)HAVE THE PRODUCTS APPROVED BY | | | HISTORIC BEFORE RESUBMITTAL. | | | | | | 7.)AS DISCUSSED, THE PRODUCT APPROVALS | | | FOR THE WINDOWS WILL BE VOIDED AS NO | | | WINDOWS ARE BEING REPLACED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
15:51 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-03-11 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2004-03-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)HISTORIC APPROVAL REQUIRED. | | | | | | 2.)CHANGES TO THE PLAN CAN ONLY BE | | | DONE BY THE DESIGNER OF RECORD. | | | | | | 3.)THE PRODUCT APPROVALS ARE | | | INCOMPLETE.THEY APPEAR TO BE THE | | | DRAWINGS ASSOCIATED WITH A DADE COUNTY | | | NOA.PROVIDE COMPLETE PRODUCT | | | APPROVALS. | | | | | | 4.)PROVIDE PRODUCT APPROVALS FOR THE | | | SIDELITES AND MULLIONS, IF YOU ARE | | | USING MULLIONS TO JOIN THE DOOR AND | | | SIDELITES.THE PRODUCT APPROVAL | | | SUBMITTED ARE FOR A DOOR WITH THE | | | SIDELITES.IF YOU ARE USING A DOOR | | | FROM ANOTHER MANUFACTURER, THIS IS NOT | | | COVERED UNDER THE PRODUCT APPROVAL | | | SUBMITTED. | | | | | | 5.)IMPACT PROTECTION REQUIRED, SUBMIT | | | SHUTTER PRODUCT APPROVALS. | | | | | | 6.)PROVIDE DESIGN PRESSURES FOR THE | | | OPENING. | | | | | | 7.)FLORIDA ARCHITECT LICENSE REQUIRED | | | TO PRACTICE ARCHITECTURE. | | | | | | 8.)PROVIDE A VALUE FOR THE NEW SCOPE | | | OF WORK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:16 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-10-06 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-03 |
Time |
06:54 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-09-23 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2003-09-23 00:00:00 | *****CORRECTIONS****** | | | | | | 1.)SHOW THE NEW ENTRY TO THE GARAGE | | | AND NEW STEPS AS PROPOSED ON THE PLAN. | | | | | | 2.)PROVIDE A STRUCTURAL DETAIL FOR THE | | | STAIRS. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-18 |
Time |
11:25 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-12-18 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:12 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-09-30 |
Time |
15:27 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-30 |
Time |
08:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-08-25 |
Time |
13:24 |
Sent To |
P |
|
| Notes |
| 2003-08-25 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE NECESSARY CHANGES TO | | | PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1,2,3,4,AND 5. | | | | | | 2} CHANGES TO PLANS MUST BE MADE BY THE | | | DESIGN PROFESSIONAL.( AIR HANDLER | | | RELOCATION). | | | | | | 3} PLEASE NOTE THAT ALL PLANS | | | THAT ARE SIGNED AND SEALED BY ARCH/ OR | | | ENGINEER ARE REQ`D PER 61G15-23.002 FOR | | | ENGINEER AND 61G1-16.004 FOR ARCH. | | | SHALL HAVE A TITLE BLOCK.SEE FAC FOR | | | REQUIREMENTS ON THE TITLE BLOCK. | | | | | | 4} PLEASE INDICATE WHERE THE PANEL IS TO | | | BE RELOCATED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-05-25 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-05-25 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | TO SMH DESK - OLD PACKAGE BROUGHT BACK | | | IN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-04-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-04-22 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-22 |
Time |
12:12 |
Sent To |
B |
|
| Notes |
| 2004-04-22 00:00:00 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-06 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-06 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
| 2004-04-06 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-27 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2004-02-27 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-17 |
Time |
16:08 |
Sent To |
E |
|
| Notes |
| 2003-12-17 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-30 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-30 |
Time |
08:24 |
Sent To |
E |
|
| Notes |
| 2003-09-30 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-21 |
Time |
10:04 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-03 |
Time |
06:54 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-10-03 |
Time |
06:54 |
Sent To |
B |
|
| Notes |
| 2003-10-03 00:00:00 | AHU MOVED CONNECTING TO EXISTING | | | DUCTWORK IN THE ATTIC. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-30 |
Time |
15:40 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-09-15 |
Time |
08:11 |
Sent To |
B |
|
| Notes |
| 2003-09-15 00:00:00 | DENIED: | | | PLEASE INDICATE SIZE OF DUCTWORK BEING | | | ADDED DUE TO THE RELOCATION OF THE | | | AHU. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-25 |
Time |
16:55 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-09-06 |
Time |
14:00 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-04-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-04-14 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-04-14 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2004-04-14 00:00:00 | GIVEN TO SAMANTHA HILL MM |
|
|