| 2003-09-09 00:00:00 | BUILDING CHECKLIST: |
| | 1-PROVIDE ENERGY CALCULATIONS AS REQ'D. |
| | SEC. 101.2.2 CHAPTER 13 FBC 2001. |
| | 2-PROVIDE FLOOR PLAN TO SCALE AND WITH |
| | DIMENSIONS. IDENTIFY ROOM TO BE USED |
| | FOR WHAT PURPOSE. SLEEPING, DINING OR |
| | FAMILY AREA. AND IDENTIFY ROOM |
| | ADJACENT TO THIS ROOM TO VERIFY EGRESS |
| | FOR BEDROOMS. SEC. 1005.4 FBC 2001. |
| | 3-SPECIFY DESIGN CRITERIA AS REQUIRED |
| | BY SEC. 1606.1.7 FBC 2001. |
| | 4-PROVIDE DETAILS AND SPECS FOR FRAMING |
| | FOR EXTERIOR DOORS AND WINDOWS. AND TO |
| | PROVIDE REINFORCING TO RECEIVE STORM |
| | SHUTTERS. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 5-FINISH FLOOR LEVEL NEED TO BE 4" MIN. |
| | ABOVE FINISH GRADE. SEC. 1804.1.7 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 6-CLARIFY HOW IS THE 5" CONCRETE RETURN |
| | WALL ATTACHED TO THE SLAB. SECTION |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 7-SPECIFY CONNECTION OF 2X4 TO CONCRETE |
| | COLUMNS AND AT THE ENDS OF WALL. SEC. |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 8-SPECIFY CONNECTION AT TOP AND BOTTOM |
| | OF WALL.SEC. 104.2.1.2 CITY AMENDMENTS |
| | 9-NEED 2X4 PRESSURE TREATED SILL AT |
| | BOTTOM OF WALL. SEC. 104.2.1.2. |
| | 10-SPECIFY PLYWOOD THICKENSS AND NAIL |
| | TYPE AND SPACING. SEC. 2306 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 11-STUCCO TO BE 7/8" MIN. THICKNESS. |
| | AS REQUIRED BY ASTM C-926. |
| | 12-SPECIFY INSULATION IN ROOF AND WALL. |
| | 13-CLARIFY IF SPACE IS GOING TO BE |
| | AIR CONDITIONED. OTHERWISE, ENOUGH |
| | WINDOW AREA NEED TO BE CALCULATED TO |
| | SATISFY VENTILATION REQUIREMENTS. |
| | SEC. 1203 FBC 2001. |
| | 14-SPECIFY VENTILATION FOR ROOF. SEE |
| | SEC. 2309.7.2 FBC 2001. |
| | 15-CLARIFY WHY SUBMITTING PRODUCT |
| | APPROVAL FOR ROOF SHINGLES. DRAWINGS |
| | CALL FOR FLAT ROOF AND SHINGLES CANN'T |
| | BE USED ON FLAT ROOFS. |
| | 16-PROVIDE PRODUCT APPROVAL FOR: |
| | A)HORIZONTAL SLIDER WINDOW. |
| | B)EXTERIOR DOOR. |
| | C)STORM SHUTTERS. |
| | |
| | 17-CONSTRUCTION VALUE DECLARED ON THE |
| | PERMIT APPLICATION IS TOO LOW. VALUE |
| | SHALL INCLUDE ALL MATERIALS AND LABOR. |
| | DECLARED A MORE REALISTIC VALUE OR |
| | ESTIMATED VALUE WILL BE CALCULATED |
| | USING THE MARSHALL & SWIFT COST |
| | ESTIMATING BOOK. |
| | 18-TAKE REVISE DRAWINGS TO PALM BEACH |
| | COUNTY TO VERIFY IF IMPACT FEES ARE |
| | DUE OR NOT. THEY WILL STAMP DRAWINGS |
| | AND GIVE YOU A RECEIPT. |
| | 19-NEED TO GO TO THE COURTHOUSE TO |
| | RECORD A NOTICE OF COMMENCEMENT. |