| Plan Review Stops For Permit 03081096 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-11-04 |
Time |
15:17 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-11-04 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-22 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-22 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2003-10-22 00:00:00 | REVISIONS DATED 9/23/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-09-02 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-09-02 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-27 |
Time |
16:24 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-15 |
Time |
08:32 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-15 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2003-10-15 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE THAT PLANS ARE JUST | | | NOW BEING CHECKED FOR ELECTRICAL. | | | PLEASE SEE THAT PLANS SUBMITTED DO NOT | | | SHOW ANY ELECTRICAL? | | | PERMIT IS BEING REQUESTED FOR ELECTRICAL | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2003-10-24 00:00:00 | TO COMM BD#58 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | TO COMM BD#47 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-11 |
Time |
04:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-26 |
Time |
11:59 |
Sent To |
P |
|
| Notes |
| 2003-09-26 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-19 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-19 |
Time |
16:11 |
Sent To |
P |
|
| Notes |
| 2003-08-19 00:00:00 | COMM/#19 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-16 |
Time |
07:33 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-10-16 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2003-10-16 00:00:00 | PROVISO: | | | EXHAUST FAN REQUIRED AS PER 2001 FBC(M) | | | 402.3.1 & TABLE 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-04 |
Time |
14:08 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-11-04 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-11 |
Time |
04:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-11 |
Time |
04:25 |
Sent To |
I |
|
| Notes |
| 2003-10-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMINISTRATION CODE | | | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT | | | ADDRESSED. 61G1-16.003 NO DATE SHOWN AS | | | TO WHEN THE PLANS WERE SIGNED AND SEALED | | | SEE ATTACHED SHEET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-26 |
Time |
11:59 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-09-17 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2003-09-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1) SUBMIT A SANITARY AND A WATER RISER | | | ISOMETRIC DIAGRAM. 104.3.1.1 | | | 2) SUBMIT A DETAIL FOR TOILET ROOM PER | | | 11-4.22. SHOW CLEAR FLOOR SPACE FOR W/C | | | 11-16.2, LAV 11-4.19.3 AND TUB 11-4.20.2 | | | SHOW HEIGHT OF W/C 11-4.16.3, SHOW FLUSH | | | CONTROLS 11-4.16.5. W/C TO BE 1'6" OFF | | | WALL FIGURE 28. FOR LAVS SHOW HEIGHT & | | | CLEARANCE 11-4.19.3, EXPOSED PIPES AND | | | SURFACES 11-4.19.4 AND FAUCETS 11-4.19.5 | | | FOR BATHTUB SHOW GRAB BAR HEIGHT FIGS | | | 33 & 34, CONTROLS 11-4.20.5 (FIG 34) | | | 3) 61G1-16.003 THE PERSONAL SEAL, SIGNA- | | | TURE AND DATE SHALL APPEAR ON EACH SHEET | | | - NO DATE ON SHEETS. - SEE ATTACHED | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|