Plan Review Details - Permit 03080423
Plan Review Stops For Permit 03080423
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-21 Cont ID  
Sent By jwitmer Date 2003-08-21 Time 09:35 Rev Time 1.50
Received By jwitmer Date 2003-08-21 Time 09:35 Sent To  
Notes
2003-08-21 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03080423
 ADD: 410 N OLIVE AVENUE
 CONT: G. T. MCDONALD
 TEL: (954)650-0024 ( BARNEY)
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 REMOVE ASPHALT & PARKING LOT FROM SITE
 PLUS VIBROFLOTATION.
  
 ACTION: BUILDING PROVISO
  
 1) THE REQUIREMENT OF A 8 FOOT HIGH
 FENCE OR SOLID WALL TO BE PROVIDED ON
 THE BUILDING SIDE OF THE PUBLIC WAY AS
 PER 3305.5.SEE PERMIT 03080421
  
 2) THE PERMIT FOR THE VIBROFLOTATION IS
 TO BE ISSUED WITH THE UNDERSTANDING AND
 IN AGREEMENT WITH SAID CONTRACTOR THAT
 THE EXCAVATION WILL NOT TAKE PLACE UNTIL
 AFTER THE VIBROFLOTATION TAKES PLACE.
  
 3) NO INFORMATION PROVIDED AT THIS TIME
 FOR THE RETAINING OF SOILS IN THE RIGHT
 OF WAY AS PER 1803.2.1 AND WILL BE RE-
 QUIRED BEFORE EXCAVATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-12 Cont ID  
Sent By jwitmer Date 2003-08-12 Time 16:17 Rev Time 3.50
Received By jwitmer Date 2003-08-12 Time 16:17 Sent To  
Notes
2003-08-12 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03080423
 ADD: 410 OLIVE DRIVE
 CONT:
 TEL: (954)650-0024
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) 3305.5 SEPERATION, A FENCE OR SOLID
 CONSTRUCTION AT LEAST 8 FT HIGH SHALL BE
 PROVIDED ON THE BUILDING SIDE OF THE
 WALKWAY.
  
 2) 1803.2.1 HOW ARE YOU GOING TO RETAIN
 SOILS FROM THE RIGHT OF WAY FROM CAVING
 IN? THE ELEVATION ON THE WEST SIDE IS
 APPROX. 11.5', THE BOTTOM OF FOOTER"C"
 IS AT 3.75'? A DIFFERENCE OF 7.75'.
 THE BUILDING LINE IS ADJACENT TO THE
 PROPERTY LINE ON THE EAST, SOUTH & WEST
 SIDES OF THE PROPERTY,THE REPORT SUBMITT
 ED FROM ARDAMAN UNDER 7.1 SITE PREPARA-
 TION RECOMMENDATIONS, INDICATE THAT
 SHEET PILING MAY BE REQUIRED FOR THE
 (3) SIDES. THE CITY WILL REQUIRE THE
 SHEET PILING ON THE EAST, SOUTH & WEST
 SIDES. THE CITY WILL ALSO REQUIRE A SEAL
 ED COPY OF THE CANTILEVER SHEETPILE WALL
 ANALYSES, THERE WILL BE AT MOST A 2.25'
 TOE THAT THE CANTILEVERED SHEET PILE
 WILL BE WORKING WITH.THE SECOND ISSUE
 WILL BE THE VIBROFLOTATIONTAKING PLACE
 AT THE 3.75' ELEVATION LEVEL, THE CITY
 NEEDS INSURANCE THAT THE VIBROFLOTATION
 ADJACENT TO THE SHEET PILING WILL NOT EF
 FECT THE PERMITER WALL, NO INWARD MOVE-
 MENT OF THE SHEET PILING NOR DAMAGE TO
 THE ADJACENT SIDEWALKS, ROADWAY OR
 INTRASTRUCTURE.
  
 4) PLEASE EXPLAIN YOUR PROCESS FOR
 DEWATERING, WELL POINT SYSTEM, WILL THIS
 BE ON THE INTERIOR SIDE OF THE SHEET
 PILING OR THE CITY SIDE? SEE7.1.3.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2003-08-22 Cont ID  
Sent By mamini Date 2003-08-22 Time 08:35 Rev Time 0.50
Received By mamini Date 2003-08-22 Time 08:35 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-08-14 Cont ID  
Sent By mamini Date 2003-08-14 Time 08:16 Rev Time 1.00
Received By mamini Date 2003-08-14 Time 08:15 Sent To  
Notes
2003-08-14 00:00:00FAILED:
 1. ALL UNDERGROUND UTILITIES IN THE AREA
 OF THE EXCAVATION MUST BE CUT AND CAPPED
 AT THE MAIN AND THE APPROPRIATE AGENCY
 SHOULD BE NOTIFIED.
 2. INSTALLATION OF 8' SAFETY FENCE ALL
 AROUND THE CONSTRUCTION SITE WILL BE
 REQUIRED.
 3. PLEASE INDICATE HOW THE WALLS 6' TO
 7' IN THE EXCAVATED AREA ALONG OLIVE
 AVE., 3RD STREET AND NEXT TO THE
 EXISTING BUILDING WILL BE RETAINED.
 4. PLANS FOR DEWATERING (WELL-POINT) AND
 METHOD OF DISCHARGE SHOULD BE INCLUDED.
 5. SIDEWALKS, CURB & GUTTERS ALONG THE
 PROPERTY IF DAMAGED DURING THE
 CONSTRUCTION MUST BE RESTORED TO
 ORIGINAL OR BETTER.
 6. PLEASE NOTE THAT PLANS MUST HAVE
 TITLE BLOCK AND SHOULD BE SIGNED AND
 SEALED BY THE DESIGN ENGINEER.
 7. ANY WORK WITHIN PUBLIC R.O.W WILL
 REQUIRE PERMIT FROM CITY ENGINEER,
 MR. RICHARD PITTMAN,659-8040.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-19 Cont ID  
Sent By alange Date 2003-08-19 Time 08:51 Rev Time 0.00
Received By alange Date 2003-08-19 Time 08:50 Sent To  
Notes
2003-08-19 00:00:00TO COMM BD #30

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-12 Cont ID  
Sent By dbaxter Date 2003-08-12 Time 13:35 Rev Time 0.00
Received By dbaxter Date 2003-08-12 Time 13:35 Sent To B
Notes
2003-08-12 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-08 Cont ID  
Sent By alange Date 2003-08-08 Time 16:36 Rev Time 0.00
Received By alange Date 2003-08-08 Time 16:36 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2003-08-14 Cont ID  
Sent By alange Date 2003-08-08 Time 16:36 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***