| Plan Review Stops For Permit 03080349 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-11-05 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-05 |
Time |
14:24 |
Sent To |
P |
|
| Notes |
| 2003-11-06 00:00:00 | COMMENTS NOW ADDRESSED.PASSED | | 2003-11-05 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 10/28/03: | | | | | | 3) FBC 11-4.15SHEET A2 HAS BEEN RED- | | | LINED TO SHOW A MAXIMUM SPOUT HEIGHT OF | | | 36" ABOVE FLOOR FOR THE WATER FOUNTAIN. | | | | | | 6) FBC 1601ANNOTATE THE PLANS TO | | | SPECIFY THE RAFTER AND BEAM FASTENERS, | | | AS PER THE 2003 SIMPSON CATALOGUE, FOR | | | THE H16 ANCHORS NOW SPECIFIED AT EACH | | | ROOF TRUSS ABOVE 'RECEIVING'. | | | | | | 7) FBC 1601ANNOTATE THE PLANS TO | | | SPECIFY THE RAFTER AND LEDGER FASTENERS, | | | AS PER THE 2003 SIMPSON CATALOGUE, FOR | | | FOR THE LSU26 AND LSTA12 NOW SPECIFIED | | | AT EACH CANOPY ROOF TRUSS. | | | | | | 13) NOTE: IF THE SUBMITTED PLANS ARE | | | REVISED MANUALLY, EACH REVISION SHALL BE | | | INITIALLED AND DATED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-31 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-28 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2003-10-28 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 8/22/03: | | | | | | 3) FBC 11-4.15SHEET A2 HAS BEEN RED- | | | LINED TO SHOW A MAXIMUM SPOUT HEIGHT OF | | | 36" ABOVE FLOOR FOR THE WATER FOUNTAIN. | | | | | | 6) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC 1606.2.4SPECIFY ANCHORS FOR THE | | | SLOPED ROOF ABOVE 'RECEIVING'.THE WIND | | | ENGINEERING / STRUCTURAL NOTES STILL DO | | | NOT STATE THE DESIGN PRESSURES FOR THE | | | ROOF STRUCTURE DESIGN. | | | | | | 7) FBC 1601STRUCTURAL DETAILS FOR | | | FASTENING OF THE NEW SLOPED CANOPIES. | | | THIS COMMENT HAS NOT BEEN PROPERLY | | | ADDRESSED.IT IS NOTED THAT SHEET A0, | | | WIND ENGINEERING / STRUCTURAL NOTES, | | | NOW INCLUDES A NOTE STATING THE UPLIFT | | | (83 POUNDS) AT EACH TRUSS ANCHOR.THIS | | | IS INSUFFICIENT FOR THE DESIGN WIND | | | PRESSURES FOR THIS LOCATION.THE LSU24 | | | ANCHOR SPECIFIED ON SHEET S1 | | | (SECTION AA) IS NOT A VALID 2003 SIMPSON | | | CATALOGUE REFERENCE.ALSO THE SPECIFIED | | | RR RIDGE RAFTER CONNECTOR IS NOT | | | SUITABLE FOR THIS APPLICATION.IT IS | | | DESIGNED FOR RAFTER TO RIDGE CONNECTIONS | | | (IN COMPRESSION) AND IS NOT APPROPRIATE | | | FOR THE TENSILE LOADING THAT MUST BE | | | RESISTED BE THE RAFTER IN MONOSLOPE | | | CANOPY ROOF UNDER GRAVITY LOAD.SPECIFY | | | VALID ANCHOR REFERENCES SUITABLE FOR THE | | | APPLICABLE LOADING (TO INCLUDE THE | | | DESIGN PRESSURES REFERENCED IN COMMENT 6 | | | ABOVE). | | | | | | 13) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-22 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-22 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2003-08-22 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC 308.2.1 DECLARE ANY HAZARDOUS | | | MATERIALS OR PROCESSES TO BE EMPLOYED/ | | | STORED IN LABORATORY FACILITY. | | | | | | 2) FBC 11-4.13.6MANEUVERING CLEARANCE | | | AT DOORS.THE DOORS BETWEEN 'RECEIVING' | | | AND 'GROSSING' SHALL HAVE 18" CLEARANCE | | | BETWEEN THE STRIKE EDGE OF THE DOORS | | | AND THE ADJACENT WORK BENCH ON THE PULL | | | SIDE OF THE DOORS FOR ACCESSIBILITY. | | | REF. FIG. 27A | | | | | | 3) FBC 11-4.15 AMEND THE PLANS TO SHOW | | | THE REQUIRED ACCESSIBILITY HEIGHTS AND | | | CLEARANCES AT THE WATER FOUNTAIN. | | | REF. FIG. 27 | | | | | | 4) FBC* 104.2.1SUBMIT DETAILS FOR THE | | | PROPOSAL TO RAISE THE FOOR LEVEL OF THE | | | EXISTING BUILDING. | | | | | | 5) FBC* 104.2.1.2SUBMIT MANUFACTURER'S | | | DETAILS TO JUSTIFY THE STATED ONE-HOUR | | | FIRE-RATING OF THE 'CHEM ROOM' POCKET | | | DOOR. | | | | | | 6) FBC 1606.2.4SPECIFY ANCHORS FOR THE | | | SLOPED ROOF.THE WIND ENGINEERING AND | | | STRUCTURAL NOTES DO NOT STATE THE DESIGN | | | WIND PRESSURES FOR THE ROOF. | | | | | | 7) FBC 1601SUBMIT STRUCTURAL DETAILS | | | FOR FASTENING OF THE NEW SLOPED | | | CANOPIES.IS THERE AN EXISTING CONCRETE | | | CANOPY AT EACH LOCATION (THE AS-BUILT | | | PLAN DOES NOT SHOW THEM)? | | | | | | 8) FBC 1707.4SUBMIT PRODUCT APPROVALS | | | FOR THE NEW WINDOWS AND EXTERIOR DOORS. | | | | | | 9) FBC* F102.2.4ALL ROOF COVERINGS IN | | | THE FIRE DISTRICT SHALL CONFORM TO THE | | | REQUIREMENTS OF CLASS A OR B ROOF | | | COVERINGS AS DEFINED IN FBC 1505. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE FOR BOTH THE RE-ROOF AND THE | | | NEW STANDING SEAM ROOF WHICH SHALL BE | | | LISTED AS CLASS A OR B BY AN APPROVED | | | TESTING AGENCY, OR SHALL MEET THE | | | THICKNESS/GAUGE/WEIGHT CRITERIA | | | SPECIFIED IN TABLE FBC 1507.3.9.2 | | | | | | 10) FBC* F102.2.7ARCHITECTURAL TRIM ON | | | BUILDINGS IN THE FIRE DISTRICT SHALL BE | | | CONSTRUCTED OF APPROVED NON-COMBUSTIBLE | | | MATERIALS.THE SIDING SHOWN ON THE | | | ELEVATIONS (SHEET A3) IS STATED AS BOTH | | | "HADIE-PLANK" AND "HARDIE-PLANK".IN | | | THE REVIEW IT HAS BEEN ASSUMED THAT THE | | | PROPOSED SIDING IS 'HARDIPLANK' (KNOWN | | | TO BE NON-COMBUSTIBLE) BY JAMES HARDIE | | | SIDING PRODUCTS.PLEASE ADVISE IF THIS | | | ASSUMPTION IS NOT CORRECT.ANNOTATE THE | | | PLANS. | | | | | | 11) FBC* F102.2.8IN THE FIRE DISTRICT, | | | CANOPIES SHALL BE OF NON-COMBUSTIBLE | | | MATERIAL OR FIRE-RETARDANT WOOD. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE | | | | | | 12) FBC* F102.2.9ROOF MOUNTED | | | MECHANICAL EQUIPMENT.SUPPORTS FOR | | | EQUIPMENT PLACED ABOVE THE ROOF OF ANY | | | BUILDING WITHIN THE FIRE DISTRICT SHALL | | | BE OF NON-COMBUSTIBLE CONSTRUCTION. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE. | | | | | | 13) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-07 |
Time |
06:03 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-11-07 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | RED LINEDGEC TO CWP. 250.50 | | | ARC FAULT SHOWN FOR BEDROOMS???? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-27 |
Time |
06:35 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2003-10-27 00:00:00 | ITEMS REDLINED AND NOTED ON PLANS. | | | CWP FOR GRND ELEC SYSTEM. 250.50 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-25 |
Time |
17:00 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-08-25 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2003-08-25 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE 422.13 FOR SIZING OF | | | OCP FOR WATER HEATER. SHOWN AS 1P30A? | | | | | | 2)NOTE: PLEASE CORRELATE OCP/KW/AWG FOR | | | AHU'S AND COND UNITS. 424.3B | | | | | | 3)NOTE: PLEASE SEE CONDUCTORS FROM MAINS | | | TO PANELS. SHOWN AS #3'S. PLEASE SEE | | | 310.16 | | | | | | 4)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215.3/230.42 ETC | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATING FOR | | | MAINS. 110.9 IT IS NOTED FOR BRANCH | | | BRKRS. | | | | | | 6)NOTE: PLEASE SEE 600.5 FOR REQ'D SIGN | | | CIRCUIT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-23 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-23 |
Time |
07:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-08-27 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-08-27 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | 1) PLEASE INDICATE WHAT CHEMICALS WILL | | | BE STORED IN THE CHEMICAL ROOM # 114. | | | WILL THERE BE ANY FLAMMABLES, | | | COMBUSTIBLES, CORROSIVES, TOXICS, ETC. | | | PLEASE PROVIDE A COMPLETE LIST | | | OF CHEMICALS AND STORAGE QUANTITIES. | | | ALSO PLEASE INDICATE IF GASES, SOLIDS, | | | OR LIQUIDS. | | | | | | 2) PLEASE PROVIDE PRODUCT APPROVALS | | | FOR 3086 POCKET ONE HOUR FIRE DOOR. | | | PLEASE BE ADVISED THAT ALL FIRE RATED | | | DOORS ARE REQUIRED TO BE EQUIPPED WITH | | | SELF-CLOSING DEVICES. | | | | | | 3) PLEASE DEFINE THE FOLLOWING TERMS | | | GROSSING, EMBEDDING, H+E STAIN, SPECIAL | | | STAIN. | | | | | | 4) NO FIRE EXTINGUISHERS SHOWN ON THE | | | PLANS. | | | | | | 5) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 6) WHAT WILL BE STORED IN THE CLOSETS. | | | | | | 7) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. | | | | | | 8) WHAT WILL BE EXHAUSTED FROM THE HOOD | | | LOCATED IN THE CHEM ROOM. A SEPARATE | | | PLAN AND PERMIT WILL BE REQUIRED. | | | | | | 9) WHAT IS THE PURPOSE 30" HIGH WORK | | | BENCHES NEAR THE MAIN EXIT DOOR. | | | | | | 10) PLEASE INDICATE OCCUPANT LOADS | | | FOR THE BUILDING. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
14:47 |
Sent To |
M |
|
| Notes |
| 2004-11-08 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
13:41 |
Sent To |
M |
|
| Notes |
| 2004-08-03 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-05-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-28 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-28 |
Time |
15:08 |
Sent To |
P |
|
| Notes |
| 2004-05-28 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-07 |
Time |
11:56 |
Sent To |
M |
|
| Notes |
| 2004-05-07 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-17 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-17 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2003-10-17 00:00:00 | TO COMM BD#34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-21 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-08-21 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | COMM BOARD #6./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-08 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-08 |
Time |
14:17 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-29 |
Time |
07:04 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-11-29 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | ORIGINAL PLANS COULD NOT BE LOCATED FOR | | | COMPARISION.SHOULD THE APPROVED PLANS | | | (ORIGINAL SET) BE DRAWN BY A MECHANICAL | | | ENGINEER, ALL REVISIONS SUBSEQUENT | | | SHALL | | | BE BY THE ENGINEER OF RECORD. | | | | | | PROVIDE MANUFACTURER INSTALLATION | | | INSTRUCTIONS FOR THE FIRE DAMPERS ON | | | THE | | | JOBSITE AT THE TIME OF INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-09 |
Time |
10:39 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-09 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
13:41 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-11-07 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | PROVISO:2ND REQUEST | | | 1.PROVIDE MANUFACTURER SUBMITTAL FOR | | | THE ROOF CURBS TO THE RTU'S.SEE | | | ATTACHED REQUIREMENTS. | | | | | | PLEASE PROVIDE SUBMITTAL PRIOR TO | | | ROUGH INSPECTION. | | | | | | 2.CONDENSATE DRAIN SHALL COMPLY WITH | | | 2001 FBC(M) 307.2.1 #2 AND #3. | | | CONDENSATE SHALL DISCHARGE A MINIMUM OF | | | 12" AWAY FROM THE BUILDING STRUCTURE AS | | | PER 2001 FBC 1503.4.4. | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | REQUIRED WITH NOTIFICATION TO ALARM | | | STROBE IN NORMALLY OCCUPIED AREAS PER | | | 2001 FBC(M) 606.2.2 & NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-31 |
Time |
10:09 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-10-31 |
Time |
10:02 |
Sent To |
B |
|
| Notes |
| 2003-10-31 00:00:00 | PROVISO: | | | 1.PROVIDE MANUFACTURER SUBMITTAL FOR | | | THE ROOF CURBS TO THE RTU'S. | | | (SEE ATTACHED) | | | | | | 2.CONDENSATE DRAIN SHALL COMPLY WITH | | | 2001 FBC(M) 307.2.1 #2 AND #3. | | | CONDENSATE SHALL DISCHARGE A MINIMUM OF | | | 12" AWAY FROM THE BUILDING STRUCTURE AS | | | PER 2001 FBC 1503.4.4. | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTORS | | | REQUIRED WITH NOTIFICATION TO ALARM | | | STROBE IN NORMALLY OCCUPIED ARES AS PER | | | 2001 FBC(M) 606.2.2 & NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-28 |
Time |
14:02 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-08-28 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2003-08-28 00:00:00 | DENIED: | | | | | | 1. PROVIDE OUTSIDE AIR CALUCALTIONS AS | | | PER 2001 FBC(M) TABLE 403.3 | | | | | | 2. PROVIDE MSDS SHEETS FOR THE CHEMICALS | | | TO BE USED IN THE "CHEM ROOM". | | | | | | 3. INDICATE HOW CHEMICALS ARE TO BE | | | STORED. | | | | | | 4. PROVIDE INFORMATION ON THE EXHAUST | | | FAN. (MAKE, MODEL, CFM, ETC) | | | | | | 5. BALANCE AIR RETURN - RETURN TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM IT'S SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-11 |
Time |
15:03 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-06-11 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2004-06-11 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) REVISIONS AS SUBMITTED NOT APPROVED. | | | NO HAND DRAWN REVISIONS. NEW SHEETS REQD | | | SUBMIT NEW SHEETS WITH ALL CHANGES. SHOW | | | REVISION NUMBER AND CLOUD CHANGES. | | | SECTION 104.2.1 | | | | | | 2) ALL REVISIONS ON FLOOR PLANS SHALL BE | | | REFLECTED ON THE RISER DIAGRAMS. SEE | | | PROVISOS AND RED LINE CORRECTIONS TO | | | BE MADE ON REVISION FROM STAMPED SET OF | | | PLANS. ALL PROVISO AND RED LINE CORRECT- | | | IONS SHALL BE REVISED AND SHOWN ON THE | | | REVISION SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-28 |
Time |
15:08 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-11-20 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2003-11-20 00:00:00 | | | | | | | | | | | | | PASSED/PROVISO | | | | | | PASSED SUBJECT TO RESPONSE FROM RODNEY | | | COMPO CONCERNING REQUIREMENT FOR A | | | DILUTION TANK FOR CHEMICAL LAB. | | | NO PLUMBING SHALL BE INSTALLED UNTILL A | | | RESPONSE HAS BEEN ISSUED. IF A DILUTION | | | TANK IS REQUIRED THAN A REVISION WILL BE | | | REQUIRED WITH THE TANK INCLUDED. | | | | | | THE SERVICE SINK SHALL CONNECT DOWN- | | | STREAM OF THE BATHROOM GROUP. SECTION | | | 909.1 - A REVISION WILL BE REQUIRED FOR | | | THE RED LINE CORRECTION SHOWN ON THE | | | SANITARY RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-11-06 |
Time |
17:29 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-10-29 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | | | | 1) FROM PREVIOUS REVIEW: CONTACT RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE, (561) | | | 837-4074. A DILUTION TANK MAY BE REQUIR- | | | ED FOR THE CHEMICALS. | | | | | | 2) SHT A2 THE SANITARY RISER DIAGRAM | | | STILL DOES NOT REFLECT THE FLOOR PLAN. | | | THE LAV PAST THE EYEWASH IS NOT SHOWN | | | ON THE FLOOR PLAN. EYE WASH SHALL BE | | | DOWNSTREAM OF THE FLOOR DRAIN. NO LUNCH | | | ROOM SINK SHOWN ON THE RISER DIAGRAM. | | | THIS SHALL TIE INTO THE LINE FOR THE | | | DRINKING FOUNTAINS. | | | 3) SEPARATE GAS PERMIT REQUIRED FOR GAS | | | WORK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-02 |
Time |
10:36 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-02 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | NEC-99 | | | FBC-2001 AMENDMENTS, CHAPTER | | | ONE, ADMINSTRATION | | | CODE. | | | | | | 1) SHT A2 INDICATE NATURE OF WORK BEING | | | PERFORMED. LIST ALL CHEMICALS & HAZARD- | | | OUS MATERIALS BEING USED. SUBMIT MSDS | | | SHEETS FOR ALL CHEMICALS AND HAZARDOUS | | | MATERIALS. AN EMERGENCY EYE WASH/SHOWER | | | MAY BE REQUIRED AS A RESULT OF INFORMAT- | | | ION RECIEVED FROM MSDS SHEETS. SECTION | | | 104.2.1. | | | 2) CONTACT RODNEY COMPO (561) 837-4074 | | | OR MARIA ORTIZ (561) 837-4061. A DILUT- | | | ION TANK MAY BE REQUIRED FOR THE CHEM- | | | ICALS. | | | 3) DETAIL REQUIRED FOR DRINKING FOUNTAIN | | | PER 11-4.15, SPOUT HEIGHT 11-4.15.2, | | | CLEARANCES/CLEAR FLOOR SPACE 11-4.15.5. | | | ALSO PROVISIONS FOR THOSE WHO HAVE DIFF- | | | ICULTY BENDING OR STOOPING PER SECTION | | | 11-4.1.3(10)(A) | | | 4) SHT A2 PLUMBING RISER, BREAK ROOM | | | SINK SHALL CONNECT DOWNSTREAM OF THE | | | TOILET ROOM FIXTURES. (SEE RED LINE | | | CORRECTIONS) SECTION 909.1 | | | 5) SHT A2 PLUMBING RISER DOES NOT RE- | | | FLECT THE FLOOR PLAN. ONE SINK SHALL BE | | | CONNECTED TO THE RIGHT SIDE OF THE BLDG. | | | DRAIN. (SEE RED LINE CORRECTION) | | | 6) A SERVICE SINK IS REQUIRED PER SECT- | | | ION 403.1 | | | 7) SECTION 422-17 NEC, PROTECTION OF | | | COMBUSTABLE MATERIAL. EACH ELECTRICALLY | | | HEATED APPLIANCE THAT IS INTENDED BY | | | SIZE, WEIGHT, AND SERVICE TO BE LOCATED | | | IN A FIXED POSITION SHALL BE PLACED SO | | | AS TO PROVIDE AMPLE PROTECTION BETWEEN | | | THE APPLIANCE AND ADJACENT COMBUSTIBLE | | | MATERIAL. - THE ELECT. WATER HEATER | | | SHALL BE IN A SEPARATE CLOSET OR A WALL | | | 6" FROM W/H SHALL BE INSTALLED TO PRE- | | | VENT STORAGE OF COMBUSTABLE MATERIAL | | | FROM BEING PLACED NEXT TO THE HEATER. | | | 8) SUBMIT DETAIL FOR BREAK ROOM SINK. | | | SHOW COMPLIANCE WITH 11-4.24 AND ALL | | | SUBSECTIONS. - CLEAR FLOOR SPACE - | | | HEIGHT - KNEE CLEARANCE - DEPTH - EX- | | | POSED PIPES & SURFACES - FAUCETS. | | | 9) SHT S2 SUBMIT CALCULATIONS FOR ROOF | | | DRAINS. SHOW SQUARE FOOTAGE OF ROOF AND | | | ADD 1/2 AREA OF ALL VERTICAL WALLS IN- | | | CLUDING PARAPET WALLS. IF GUTTER AND | | | DOWNSPOUTS INDICATE SIZE OF DOWNSPOUTS | | | & LOCATION. INDICATE SIZE OF GUTTER AND | | | SLOPE PER SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. | | | 10) APPLICATION INDICATES IRRIGATION | | | WORK TO BE DONE. SEPARATE PERMIT/PLANS | | | REQUIRED FOR IRRIGATION. | | | 11) SHT A1, ALL REMOVED AND CAPPED | | | PLUMBING LINES SHALL BE INSPECTED PRIOR | | | TO COVERING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-20 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-08-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|