Plan Review Details - Permit 03080326
Plan Review Stops For Permit 03080326
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-01-09 Cont ID  
Sent By rbrown Date 2004-01-09 Time 14:33 Rev Time 0.00
Received By rbrown Date 2004-01-09 Time 14:33 Sent To  
Notes
2004-01-09 00:00:00REVISION SUBMITTED 12/9/03 FOR BLDG/
 ELEC/MECH/PLUMBING

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-03 Cont ID  
Sent By rbrown Date 2003-12-03 Time 11:45 Rev Time 0.00
Received By rbrown Date 2003-12-03 Time 11:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-08-21 Cont ID  
Sent By jleech Date 2003-11-25 Time 17:55 Rev Time 0.00
Received By rbrown Date 2003-08-21 Time 10:52 Sent To  
Notes
2003-08-21 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 --PROVISO--
 SHEET A.3 REDLINED:DETAIL 8/A.3 AND
 10/A.3 TO REFERENCE UL LISTED ASSEMBLIES
 FROM 2003 DIRECTORY.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-17 Cont ID  
Sent By dpalmer Date 2003-12-17 Time 07:27 Rev Time 0.25
Received By dpalmer Date 2003-12-17 Time 07:25 Sent To  
Notes
2003-12-17 00:00:00SAME PLAN AS PREVIOUS REVIEW.
 NO REV.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-04 Cont ID  
Sent By dpalmer Date 2003-11-04 Time 07:17 Rev Time 0.25
Received By dpalmer Date 2003-11-04 Time 07:17 Sent To  
Notes
2003-11-04 00:00:00REDLINED RECEPTS TO BE GFI 210.8

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-18 Cont ID  
Sent By dpalmer Date 2003-08-18 Time 09:04 Rev Time 0.33
Received By dpalmer Date 2003-08-18 Time 09:04 Sent To  
Notes
2003-08-18 00:00:00EXIST RECEPTS TO BE GFI.210.8

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-11-14 Cont ID  
Sent By mcarsill Date 2003-11-14 Time 15:48 Rev Time 0.00
Received By mcarsill Date 2003-11-14 Time 15:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-08-26 Cont ID  
Sent By nmccray Date 2003-08-26 Time 10:50 Rev Time 0.00
Received By nmccray Date 2003-08-26 Time 10:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-12-29 Cont ID  
Sent By csiegber Date 2003-12-29 Time 14:09 Rev Time 0.00
Received By csiegber Date 2003-12-29 Time 14:09 Sent To M
Notes
2003-12-29 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-12-09 Cont ID  
Sent By csiegber Date 2003-12-09 Time 15:26 Rev Time 0.00
Received By csiegber Date 2003-12-09 Time 15:26 Sent To  
Notes
2003-12-09 00:00:00TO COMM BD#58

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-11-03 Cont ID  
Sent By csiegber Date 2003-11-03 Time 12:46 Rev Time 0.00
Received By csiegber Date 2003-11-03 Time 12:46 Sent To  
Notes
2003-11-03 00:00:00TO COMM BD#2

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-31 Cont ID  
Sent By lsmith Date 2003-10-31 Time 09:47 Rev Time 0.00
Received By lsmith Date 2003-10-31 Time 09:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-07 Cont ID  
Sent By alange Date 2003-08-07 Time 14:16 Rev Time 0.00
Received By alange Date 2003-08-07 Time 14:16 Sent To  
Notes
2003-08-07 00:00:00TO COMM BD
 IN BOX NO. 28 W/ TWO OTHER PERMITS

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2004-01-09 Cont ID  
Sent By pkrauss Date 2004-01-09 Time 07:06 Rev Time 0.35
Received By pkrauss Date 2004-01-09 Time 07:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2003-12-30 Cont ID  
Sent By pkrauss Date 2003-12-30 Time 09:12 Rev Time 0.25
Received By pkrauss Date 2003-12-30 Time 09:11 Sent To  
Notes
2003-12-30 00:00:00NO REVISION FOR MECHANICAL SUBMITTED
 ON 12-9-03.MECHANICAL PLANS ON SHEET
 A.2

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-12-03 Cont ID  
Sent By csiegber Date 2003-12-29 Time 14:09 Rev Time 0.15
Received By pkrauss Date 2003-12-03 Time 12:26 Sent To  
Notes
2003-12-03 00:00:00MECHANICAL PLAN ON PLAN SHEET A.2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-11-22 Cont ID  
Sent By hmoser Date 2003-11-22 Time 07:52 Rev Time 0.50
Received By hmoser Date 2003-11-22 Time 07:52 Sent To  
Notes
2003-11-22 00:00:00PLAN DENIED NO PLANS.11/22/03 H.M.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-09-08 Cont ID  
Sent By kstevens Date 2003-09-08 Time 18:13 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-12-19 Cont ID  
Sent By kstevens Date 2003-12-19 Time 11:32 Rev Time 0.75
Received By kstevens Date 2003-12-19 Time 11:32 Sent To  
Notes
2003-12-19 00:00:00REVISION OK - CHANGED DRINKING FOUNTAIN
 TO HI-LOW TO SINGLE UNIT. CUP DISPENSER
 REQUIRED. - DELETED MOP SINK. FIELD
 INSPECTOR SHALL VERIFY SERVICE SINK
 REQUIREMENTS. MOVED LAV TO STALL

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-11-25 Cont ID  
Sent By jleech Date 2003-11-25 Time 17:54 Rev Time 1.00
Received By jleech Date 2003-11-25 Time 17:54 Sent To B
Notes
2003-11-25 00:00:00DENIED;
 1.SHOW MINIMUM PLUMBING FACILITIES TO
 JUSTIFY REMOVEL OF ONE LAV. AND ONE
 TOILET FROM THE FEMALE RESTROOM SEE
 SEC.403.1.1.2 AND 403.3.3.
 2.PLUMBING FIXTURE LEGEND.
 A.EWC CALL FOR TWO LEVEL DRINKING
 FOUNTAIN FLOOR PLAN SHOWS SINGLE
 LEVEL.
 B.MOP SINK STILL ON LEGEND, FLOOR
 PLAN DOES NOT SHOW LOCATION.
 3.DETAIL EWH RISER DIAGRAM. REMOVE IF
 WATER HEATER IS NOT BEING MOVER. FOR
 POINT OF REFERENCE WHERE IS WATER
 HEATER?
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-09-08 Cont ID  
Sent By alange Date 2003-08-07 Time 14:17 Rev Time 0.50
Received By kstevens Date 2003-09-08 Time 18:13 Sent To  
Notes
***NONE***