| Plan Review Stops For Permit 03080097 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-10-02 |
Time |
07:32 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-10-02 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2003-10-02 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE PERMIT WAS ISSUED WITH A | | | PROVISO TO SUBMIT A DETAIL FOR THE | | | RAILING AND GUARDRAIL TO COMPLY WITH | | | FBC1608.2, 1007.5, 1015.3.REVISE | | | PLAN. | | | | | | 2.)SPECIFY ATTACHMENTS (SECTION B, | | | SIMPSON JOIST HANGER, SECTION A, TS). | | | SIMPSON HDSA IS NOT IN THE 2003 CATALOG, | | | SPECIFY ATTACHMENT (SECTION B). | | | | | | 3.)IMPACT PROTECTION REQUIRED, FBC | | | 1606.1.4. | | | | | | 4.)SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR THE FRENCH DOORS, NEW | | | WINDOW, AND IMPACT PROTECTION. | | | | | | 5.)ENERGY CALCS REQUIRED, FBC13-101.2. | | | SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALC. | | | | | | 6.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 7.)AREA CALCULATIONS REQUIRED ON THE | | | PLAN; EXISTING AND PROPOSED, NEW TOTAL. | | | | | | 8.)TO EXPEDITE PLAN REVIEW, CLOUD OR | | | OTHERWISE INDICATE ALL CHANGES.FOR | | | EXAMPLE, THE NEW WINDOW AND THE STEEL | | | IN SECTION B ARE NOT MARKED BUT ARE | | | CHANGES FROM THE PERMITTED SET. | | | | | | 10.)AS DISCUSSED WITH THE OWNER, | | | REVISE THE PLAN TO REFLECT THE ACTUAL | | | REPAIR TO THE CONCRETE POSTS.PER OUR | | | CONVERSATION, THE STEEL WAS REPLACED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-29 |
Time |
11:04 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-08-22 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2003-08-22 00:00:00 | ******PROVISO****** | | | 1.)SUBMIT STEEL DETAIL AS A REVISION. | | | 2.)RAILING AND GUARDRAIL TO COMPLY WITH | | | FBC1007.5.1, 1007.5.3,1608.2,1015.3. | | | SUBMIT A REVISED STAIR DETAIL BEFORE | | | CONSTRUCTION. | | | 3.)CALL FOR PREINSPECT, 805-6651 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-29 |
Time |
11:04 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-29 |
Time |
11:04 |
Sent To |
B |
|
| Notes |
| 2003-09-29 00:00:00 | ************ UNSAT ****************** | | | | | | 1NOTE: PLEASE SUBMIT PLANS UNDER PERMIT | | | # IN WHICH ELECTRICAL REVIEW AND PERMIT | | | WAS ISSUED. | | | NO REVIEW WAS DONE UNDER THIS # FOR | | | PERMIT. | | | | | | 2)NOTE: PLEASE NOTE, BEFORE SUBMITTING | | | SAME ELECTRICAL SHEETS, PLEASE SEE THE | | | 2002 NEC AND THE 1999 NFPA-72 8-1 | | | FOR MANY ITEMS MISSING ON PLANS AND | | | INCOMPLETE PLANS ALSO. | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | UNDER ELEC #. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-26 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-08-22 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2003-08-22 00:00:00 | REMOVED ELECTRIC PLAN FROM PACKAGE; | | | OWNER TO APPLY FOR ELECTRIC PERMIT | | | SEPARATELY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-19 |
Time |
16:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-08-21 |
Time |
13:08 |
Sent To |
B |
|
| Notes |
| 2003-08-21 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE NECESSARY CHANGES ON | | | PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2} INDICATE COMPLIANCE WITH 250-50 FOR | | | THE GEC SYSTEM AND SIZE OF CONDUCTOR. | | | | | | 3} THE ELECTRICAL FLOOR PLANS DO NOT | | | MATCH THE ARCHITECTURAL FLOOR | | | PLAN,PLEASE CORRELATE. | | | | | | 5} PROVIDE A LOAD CALCULATION AND PANEL | | | SCHEDULE PER 215.5 NEC.INDICATE REQUIRED | | | CIRCUITS ON SAME. | | | | | | 6} PLEASE SEE THE 2002 NEC FOR | | | ELECTRICAL REQUIREMENTS AND | | | NFPA-72,1999,FOR SMOKE DETECTION | | | DEVICES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-19 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-09-19 |
Time |
12:14 |
Sent To |
Z |
|
| Notes |
| 2003-09-19 00:00:00 | SENT TO ZONING 9/16, APPARENTLY NOT | | | REVIEWED, SENT BACK TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-16 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-09-16 |
Time |
16:21 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-09 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-09 |
Time |
10:14 |
Sent To |
B |
|
| Notes |
| 2003-09-09 00:00:00 | TO ST DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-14 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
16:11 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-26 |
Time |
09:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-09-26 |
Time |
09:36 |
Sent To |
E |
|
| Notes |
| 2003-09-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMIN. CODE | | | | | | 1) SEPARATE PLUMBING PERMIT REQUIRED | | | 2) SHT A-1 WASH MACHINE REQUIRES A TRAP, | | | AND STANDPIPE. SECTIONS 1002.1 & 802.4 | | | 3) CLEANOUT REQUIRED ON W/M STACK 4 FEET | | | ABOVE THE FLOOR. 708.10. | | | 4) THE PERSONAL SEAL, SIGNATURE, AND | | | DATE SHALL APPEAR ON SHEETS. NO DATE | | | WHERE SIGNED AND SEALED. 61G1-16.003 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-09-19 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
| 2003-09-19 00:00:00 | 9/19/03 OK PER SHIRLEY GRAHAM ASSOC | | | PLANNER MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-19 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | 8/6/03 DENIED, NEED SITE PLAN TO SHOW | | | LOCATION OF STAIRS IN REAR/CANNOT PULL | | | PERMIT AS OWNER BUILDER MM |
|
|