Plan Review Details - Permit 03080042
| Plan Review Stops For Permit 03080042 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-18 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-18 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | PLAN REVIEW NOT A PERMIT APPLICATION. | | | | | | IF NOTICE OF ACCEPTANCE AND/OR TEST | | | REPORTS FOR THE ROOF COVERING, DOORS | | | AND WINDOWS ARE NOT INCLUDED AT TIME OF | | | PERMIT APPLICATION, WITH AN | | | INSTALLATION SCHEDULE, A SEPARATE | | | PERMIT AND FEES WILL BE REQUIRED FOR | | | THAT WORK. | | | | | | THE EIFS MUST BE INSTALLED IN ACCORDANCE | | | WITH ITS LISTING, FBC 2603.6. | | | | | | THE EIFS SHOWN AS ARCHITECTURAL TRIM | | | MUST COMPLY WITH FBC 1404.1 AND FBC | | | F102.2.7 AS AMENDED BY THE CITY OF WEST | | | PALM BEACH. A COPY IS ATTACHED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-20 |
Time |
06:40 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-08-20 |
Time |
06:16 |
Sent To |
|
|
| Notes |
| 2003-08-20 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING FOR ALL | | | EM.EXT LTS PER 700.12E. | | | | | | 2)NOTE: PLEASE SUBMIT FIXTURE SCHEDULES | | | CONTAINING WATTAGES/VOLTAGES FOR FIXTURE | | | -S. | | | | | | 3)NOTE: PLEASE CORRELATE CIRCUITING ON | | | PLANS WITH SUBMITTED PANEL SCHEDULES/ | | | MAX LOAD PER CIRCUIT. | | | A COMPLETE AND ACCURATE PANEL SCHEDULES | | | WILL BE REQ'D BEFORE FINAL ALSO. | | | | | | 4)NOTE: PLEASE INCLUDE LOADS ON PANELS | | | 215.5 | | | | | | | | | 5)NOTE: PLEASE SEE ATTACHED COPIES OF | | | FAC 61G15-23.002 FOR ENGINEERS AND | | | 61G1-16.004 FOR ARCH'S. PLEASE SEE ALL | | | INFORMATION REQ'D ON TITLE BLOCKS FOR | | | PLANS. REQ'D ALSO UNDER FS 471/481 | | | | | | PLEASE NOTE; PLANS HAVE ONLY COME IN FOR | | | PLAN REVIEW AND NOT FOR PERMIT. | | | PLEASE SEE ANY COMMENTS FROM OTHER | | | REVIEWS THAT MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-08-21 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-08-21 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | PLEASE SEE PLAN REVIEW COMMENTS FOR | | | PHASE I, PERMIT # 03080048. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2003-08-04 00:00:00 | COMM BD# 62 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-21 |
Time |
09:32 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-08-21 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | PLAN CHECK - PLANS DATED 7/28/03 | | | | | | PLEASE PROVIDE A NARRATIVE AS TO THE | | | EXISTING SMOKE CONTROL OR SMOKE EVAC | | | SYSTEM AND HOW THE NEW SYSTEM WILL BE | | | INCORPORATED INTO THE EXISTING SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-02 |
Time |
15:17 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-02 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA STATUTES | | | FBC-2001 AMENDMENTS, CHAPTER | | | ONE, ADMIN. CODE | | | | | | 1) SHTS MP060 & MP061 ALL TERMINATED OR | | | CAPPED PLUMBING LINES TO BE INSPECTED | | | PRIOR TO COVERING. | | | 2) SHT MP060 CLAIRFICATION REQUIRED FOR | | | G.W. LINE CAP OFF. (PASSES THROUGH KEY | | | CAFE RESTURANT. | | | 3) SHT MP201 DETAIL 1/MP202 ON SHEET | | | MP201? PLEASE CLAIRFY. | | | 4) SHT MP-201 DETAIL 3/MP201 FOR SECOND | | | FLOOR. 2ND FLOOR NOT IN PHASE 2 AS IN- | | | DICATED ON APPLICATION. NO 2ND FLOOR | | | FLOOR PLANS SHOWN. | | | 5) SHT MP201 DETAIL 4/201 NOT FOUND ON | | | FLOOR PLAN. PLEASE CLAIRFY. | | | 6) SANITARY RISER DIAGRAMS AND WATER | | | RISER DIAGRAMS REQUIRED PER SECTION | | | 104.2.1 | | | 7) 61G1-16.004(2) FIRM LICENSE NUMBER | | | REQUIRED ON TITLE BLOCK FOR EACH SHEET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|