| Plan Review Stops For Permit 03080040 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-01 |
Time |
16:11 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-06-01 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | ****CORRECTIONS**** | | | RAILING SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | 1.)THE RAILING DETAILS ARE GENERIC AND | | | ILLEGIBLE.THEY ARE PREPARED BY AN | | | ENGINEER OTHER THAN EOR AND NOT SEALED. | | | | | | | | | 2.)PLEASE SUBMIT LEGIBLE DRAWINGS JOB | | | SPECIFIC.DOCUMENTS PREPARED BY AN | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD | | | ARE TO SIGNED SEALED ORIGINALS | | | FAC61G15-23.002. | | | | | | 3.)IF THE RAILING DETAIL (WITH DESIGN | | | CRITERIA FBC1608.2.2) IS PREPARED BY AN | | | ENGINEER OTHER THAN EOR, HAVE THE | | | DOCUMENT REVIEWED BY EOR. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-24 |
Time |
13:21 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-24 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2004-03-24 00:00:00 | REVISION FOR CONNECTORS DATED 3/24/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-05 |
Time |
14:00 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-03-05 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2004-03-05 00:00:00 | PROVISO | | | 1.) SUBMIT DETAIL (REVISION) FOR | | | RAILINGS BEFORE INSTALLATION. | | | 2.) SUBMIT REVISED CONNECTORS OR | | | SUBMIT CALCULATIONS OR TECHNICAL | | | BULLETIN FROM MFGR. | | | 3.) SUBMIT REVISED EN CALC FOR WHOLE | | | HOUSE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-04 |
Time |
11:04 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-02-23 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2004-02-23 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.) TWO COPIES OF ALL PERMIT DOCUMENTS | | | MUST BE SUBMITTED.ONLY ONE COPY OF THE | | | HVAC CALCS, RAILING DETAIL, AND SURVEY | | | WAS SUBMITTED. | | | | | | 2.)SEPARATE PERMIT REQUIRED FOR | | | FENCING; PRODUCT APPROVALS NOT | | | REQUIRED. | | | | | | 3.)STUCCO OVER WIRE LATH IN A VERTICAL | | | APPLICATION IS TO BE 7/8", FBC2504.2.2, | | | ASTM C926. | | | | | | 4.)ENERGY CALCS REQUIRED FBC13-101.2. | | | | | | 5.)GUARDRAILS ARE TO COMPLY WITH | | | FBC1608.2.2 AND FBC1007.SUBMIT A | | | DETAIL SHOWING COMPLIANCE BEFORE | | | INSTALLATION. | | | | | | 6.)THE PRINTED LICENSE NUMBER OF | | | THE PERSON SEALING THE PLAN IS TO BE | | | ON EACH SHEET, FAC61G15-23.002. | | | | | | 7.)CONNECTOR CS185 (SHEET A5) IS NOT | | | IN THE SIMPSON CATALOG.CS18 FASTENING | | | CONFLICTS WITH THE CATALOG.ALL | | | CONNECTORS SPECIFIED SHOULD BE FROM | | | THE HIGH WIND CATALOG.FASTENING WHICH | | | IS NOT CONSISTENT WITH THE | | | MANUFACTURER'S SPECIFICATIONS ARE TO | | | EITHER HAVE A TECHNICAL BULLETIN | | | SUPPLIED BY THE MANUFACTURER OR | | | SEALED ENGINEER'S CALCULATIONS.CHECK | | | ALL CONNECTORS. | | | | | | 8.)PROVIDE THE APPROVED SITE PLAN | | | STAMPED BY ZONING. | | | | | | 9.)TRUSS BOTTOM CHORD LIVE LOAD IS TO | | | BE A MINIMUM OF 10, FBC TABLE 16014.1. | | | THE ENGINEER'S TITLE BLOCK IS TO BE ON | | | EVERY SHEET.A PHOTOCOPY OF A SIGNATURE | | | IS NOT ACCEPTABLE.CORRECTED TRUSS | | | DRAWINGS MUST BE AVAILABLE AT TIME OF | | | INSPECTION. | | | | | | 10.)SUBMIT THE ORIGINAL APPROVED | | | MECH/ELEC/PLUMBING SHEETS.THE SHEETS | | | SUBMITTED WERE PHOTOCOPIES; MUST BE | | | SIGNED/SEALED WHEN AN ENGINEER'S TITLE | | | BLOCK IS ON THE PAGE. | | | | | | 11.)WHEN RESUBMITTING, REMOVE OLD | | | SHEETS AND REPLACE WITH REVISED SHEETS. | | | SUBMIT OLD SHEETS SEPARATELY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-11-03 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | THE SURVEY DOES NOT AGREE WITH THE SITE | | | PLAN ON THE SOUTH ELEVATION. | | | | | | SHEET A2 DOES NOT HAVE INFORMATION FOR | | | THE 2-2X6 TO SUPPORT THE H-7 TRUSS LIKE | | | GRADE, SPECIES, LAP LENGHT OR FASTENING | | | METHODS. | | | | | | THE NEW 24"X24" FOOTING DOES NOT A | | | LENGTH MEASUREMENT, MINIMUM SOIL | | | BEARING VALUE OR DEPTH BELOW GRADE. | | | | | | WHAT WILL BE DOWELED TO THE EXISTING | | | FOOTER BETWEEN THE DINING ROOM AND | | | KITCHEN. | | | | | | THE ROOM DIMENSIONS DO NOT DEFINE THE | | | NEW CONSTRUCTION TO THE EXISTING. | | | | | | THE 18'X5' PORCH DOES NOT HAVE | | | DIMENSIONS TO LOCATE THE FOOTING PIERS. | | | | | | THERE ARE NO DETAILS FOR THE | | | CONSTRUCTION OF THE BREAKFAST ROOM WALL | | | @ THE 45 DEEGREE ANGLE. | | | | | | THE TYPICAL HEADER DETAIL DOES NOT SHOW | | | A CONTINUOUS LOAD PATH TO THE | | | FOUNDATION. | | | | | | THERE ARE NO FRAMING PLANS FOR THE | | | SECOND FLOOR. | | | | | | THE DELEGATION OF TRUSS DESIGN IS NOT | | | SHOWN OR LOADS SPECIFIED. | | | | | | THERE IS STILLNO INFORMATION FOR THE | | | CONNECTION OF THE TRUSSES TO THE | | | EXISTING ROOF OR THE REQUESTED | | | COMPUTATIONS TO DEMONSTRATE THE | | | CAPABILITY OF THE EXITING CONSTRUCTION. | | | TAX RECORDS INDICATE THIS HOUSE WAS | | | CONSTRUCTED PRIOR TO 1940. | | | | | | IN SECTION CC, WHAT WILL THE HEAD ROOM | | | BE ON THE SECOND FLOOR BALCONY? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-27 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-09-09 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2003-09-09 00:00:00 | PLEASE PROVIDE A RECENT SIGNED, SEALED | | | AND DATED PROPERTY SURVEY. | | | | | | THE SITE PLAN ON SHEET A1 IS NOT CLEAR | | | AS TO THE SIZE AND LOCATION OF THE | | | ADDITION AND PORCHES.THE OTHER SHEETS | | | ARE LACKING DIMENSIONS AS WELL FOR THE | | | NEW WORK.PLEASE REVISE AS NECESSARY. | | | | | | THE DRIVE APPROACH SHOWN ON SHEET A1 IS | | | NOT ACCEPTABLE IN WEST PALM BEACH. | | | CONTACT M. AMINI AT 805-6723 FOR | | | SPECIFIC INFORMATION. | | | | | | THE ROOF TRUSSES DATED 7/29/03 DO NOT | | | SHOW THE MINIMUM 10# LIVE LOAD FOR THE | | | BOTTOM CHORD IN ACCORDANCE WITH FBC | | | TABLE 1604.1 FOR ATTICS WITHOUT STORAGE. | | | PLEASE REVISE AS NECESSARY. | | | | | | THE TRUSS ENGINEERING SHOWS A 15# DEAD | | | LOAD FOR THE TOP CHORD.SINCE A | | | CONCRETETILE ROOF COVERING IS PROPOSED, | | | WHAT IS THE ASSUMED WEIGHT OF | | | MATERIALS?IE; PLYWOOD SHEATHING, FELT | | | MATERIALS, ETC.HAS THE ENGINEER OF | | | RECORD REVIEWED THE TRUSS DRAWINGS? | | | | | | SEVERAL OF THE TRUSSES ARE SHOWN AS | | | SUPERIMPOSING POINT LOADS > 1000 LBS ON | | | THE EXISTING ROOF STRUCTURE AS WELL AS | | | INTERIOR BEARING WALLS NOT INDICATED ON | | | THE PLANS. | | | PLEASE PROVIDE COMPUTATIONS | | | DEMONSTRATING THE ABILITLY OF THE | | | EXISTING STRUCTURE | | | TO SUPPORT THE NEW CONSTRUCTION. | | | | | | SHEET A3.PROVIDE A FRAMING DETAIL FOR | | | THE TWO NEW DOOR OPENINGS ON THE FRONT | | | PORCH SECOND FLOOR BALCONY.FBC 104.2. | | | | | | WHAT IS THE DESIGN LOAD FOR THE BALCONY? | | | | | | PLEASE SHOW A CONSTRUCTION DETAIL AND | | | DESIGN LOADS FOR THE BALCONY GUARD | | | RAILS. SEE FBC 104.2. | | | | | | WHAT IS THE SPACING OF THE FRONT PORCH | | | COLUMNS? | | | | | | SHEET A3, SECTION C-C. THE NOTE "2X6 | | | STRAPPED TO EXISTING WALL STUDS" IS | | | POOR ENGINEERING DESIGN FOR A BALCONY. | | | PLEASE PROVIDE A CONSTRUCTION DETAIL | | | WITH SPECIFIC INFORMATION. | | | | | | SECTION A-A CALLS OUT J BOLTS FOR | | | ANCHORING THE BOTTOM PLATE.WILL THERE | | | BE ANY WASHERS? | | | | | | THE FRONT AND REAR PORCHES INDICATE | | | STEPS.PLEASE PROVIDE DIMENSIONS AND | | | CONSTRUCTION DETAILS. | | | | | | A3 SECTION C-C.THE ROOF CONNECTION FOR | | | THE PORCH TO THE EXISTING.WILL THERE | | | BE ANY MODIFICATION TO THE EXISTING FOR | | | UPLIFT? | | | | | | SHEET A2. WHAT IS THE SPACING OF THE | | | RAFTERS, SHEATHING AND DESIGN LOAD FOR | | | THE SHED ROOF?SEE FBC 104.2. | | | | | | WHAT IS THE FOOTING SIZE FOR THE SHED? | | | | | | SHOW THE TERMITE TREATMENT FOR THE SOIL | | | AS PROVIDED FOR IN FBC 1816. | | | | | | SHEET A2.WHAT IS THE NOTE IN THE | | | DINING ROOM AREA "DOWEL INTO EXISTING | | | FOOTING" INDICATIVE OF? | | | | | | SHOW THE ATTIC ACCESS AND VENTILATION AS | | | REQUIRED BY FBC 2309.6 AND 2309.7. | | | | | | THE ADDITION MAY BE SUBJECT TO IMPACT | | | FEES COLLECTED BY COUNTY.THE PERMIT | | | PLANS MUST BE STAMPED BY THAT OFFICE | | | AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION BEFORE A | | | PERMIT MAY BE ISSUED.CALL | | | 561-233-5025 FOR MORE INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-03 |
Time |
07:37 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-12-03 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2004-12-03 00:00:00 | REVISED PLANS, OK. | | | | | | LTR FROM ENGINEER OF RECORD(GORDON BUCK) | | | HE IS NO LONGER ENGINEER OF RECORD FOR | | | ELECTRICAL PLANS/WORK ON THIS PROJECT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-09-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-23 |
Time |
07:28 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-09-23 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2004-09-23 00:00:00 | ********* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE ORIGIANL PLANS ARE | | | SIGNED AND SEALED BY AN ENGINEER. | | | ANY REVISIONS TO PLANS ON FILE MUST BE | | | REVISED ORIG ENG. | | | FS 471 | | | PLEASE CALL FOR OTHER OPTIONS. | | | | | | 2)NOTE: PLEASE SEE THERE ARE NUMEROUS | | | CIRCUITS SHOWN ON PANEL SCHEDULES WHICH | | | SHOW 20A BRKR AND #14 AWG. | | | PLEASE SEE MANY OF THESE CIRCUITS ARE | | | REQUIRED TO BE 20A CIRCUITS. | | | | | | 3)NOTE: PLEASE SEE ALL EQUIPMENT LISTED | | | ON PANEL "D" ARE NOT SHOWN ON PLAN? | | | PLEASE ALSO SEE WATER HEATER INDICATED | | | IN SHED BUT NOT ON PANLE SCHEDULE? | | | | | | 4)NOTE: PLEASE SEE A WATER HEATER IS | | | SHOWN ON PANEL "B" BUT NOT SHOWN ON MAIN | | | HOUSE PLANS? | | | | | | 5)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED. 210.8A6 | | | | | | 6)NOTE: PLEASE SEE 210.52C1-5 FOR REQ'D | | | RECEPT SPACING ALONG KITCHEN COUNTER- | | | -SPACE. THERE ARE SOME MISSING. | | | | | | 7)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANEL "A" FOR SUB-FEED CONDCUTOR | | | SIZES. | | | | | | 8)NOTE: PLEASE SEE OCP AND AWG FOR BOTH | | | AHU'S. SHOWS 50A OCP AND #6 FOR 5KW | | | HEAT INDICATED ON LOAD CALCULATIONS?? | | | 424.3B | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-16 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-04 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-27 |
Time |
11:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-10-27 |
Time |
11:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
05:14 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-08-14 |
Time |
14:03 |
Sent To |
P |
|
| Notes |
| 2003-08-18 00:00:00 | PROVISO | | | FAILED | | | ~~~~~~ | | | PLEASE MAKE NECESSARY CHANGES TO PLANS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PANEL "B" MUST BE GROUNDED PER | | | 250-32,PLEASE SHOW SAME ON PLANS. | | | | | | 2} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110.9. | | | | | | 3} PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210.52E. | | | | | | 4} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 5} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210.12 | | | | | | 6} THE DINING ROOM RECEPTACLE SPACING | | | MUST COMPLY WITH 210.52(A)(1). | | | | | | 7} THE KITCHEN COUNTERTOP RECEPTACLES | | | MUST BE GFI PROTECTED PER 210.8(A)(6). | | | AND THE SPACING PER210.52(C)(1). | | | | | | 8} THE BEDROOMS NEED RECEPTACLES ADDED | | | TO COMPLY WITH 210.52(A)(1)&(2). | | | | | | 9} THE BEDROOMS MUST COMPLY WITH 210.70. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-27 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-27 |
Time |
11:44 |
Sent To |
B |
|
| Notes |
| 2005-05-27 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-30 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-30 |
Time |
17:28 |
Sent To |
E |
|
| Notes |
| 2004-11-30 00:00:00 | SENT TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-16 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-16 |
Time |
11:08 |
Sent To |
E |
|
| Notes |
| 2004-09-16 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-02 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-03-02 |
Time |
13:51 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-01 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2004-03-01 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-11 |
Time |
15:05 |
Sent To |
B |
|
| Notes |
| 2004-02-11 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-16 |
Time |
11:16 |
Sent To |
M |
|
| Notes |
| 2003-10-16 00:00:00 | TO PK BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-13 |
Time |
11:09 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
13:10 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
08:02 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-21 |
Time |
13:23 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-09-21 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-17 |
Time |
13:08 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-10-17 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
11:16 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-08-26 |
Time |
13:19 |
Sent To |
B |
|
| Notes |
| 2003-08-26 00:00:00 | DENIED: | | | PLEASE PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS AS PER 2001 FBC CHAPTER 13 | | | SUB-SECTION 600. | | | | | | RETURN AIR REQUIRED AS PER 2001 FBC(M) | | | 601.4 | | | BALANCE AIR RETURN - RETURN TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM IT'S SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
05:14 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-25 |
Time |
05:14 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-10-24 |
Time |
12:37 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-08-22 |
Time |
12:24 |
Sent To |
M |
|
| Notes |
| 2003-08-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-1 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS, NOR DOES IT | | | REFLECT THE FLOOR PLAN. | | | A) ONLY THE FIXTURES WITHIN THE BATH- | | | ROOM GROUPS SHALL CONNECT TO THE WET- | | | VENTED HORIZONTAL BRANCH DRAIN. ANY | | | ADDITIONAL FIXTURES SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT. SEC 909.1 | | | WASH MACHINE ON 2ND FLOOR. | | | B) STANDPIPES ARE REQUIRED AT WASH | | | MACHINES. | | | C) SHOWER BATHROOM 2ND FLOOR SHOWS TWO | | | LAVS ON FLOOR PLAN, BUT ONLY ONE ON SANT | | | RISER DIAGRAM. | | | 2) SHOW DIMENSIONS FOR SHOWERS. MINIMUM | | | SIZE 900 SQ INCHES. SHOWER COMPARTMENTS | | | SHALL NOT BE LESS THAN 30" INSIDE FIN- | | | ISHED SIDE TO SIDE. SECTION 417.4. | | | 3) SHOW SIZE OF OPENINGS FOR ALL WATER | | | CLOSETS. PER SECTION 504.3.1 | | | 4) SHOW MEASUREMENTS FOR TOILET ROOMS | | | 5) PROVIDE DETAILS FOR FLOOR DRAINS. IN- | | | DICATE HOW THESE WILL BE MADE WATERPROOF | | | OR WATER TIGHT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-04 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-04 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2004-03-04 00:00:00 | APPROVED BY ANA MARIE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-02 |
Time |
13:51 |
Rev Time |
0.25 |
| Received By |
ajones |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|