Plan Review Details - Permit 03072437
| Plan Review Stops For Permit 03072437 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-09-10 |
Time |
12:16 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-09-10 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-08 |
Time |
08:58 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-08-25 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2003-08-25 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) REVISE STUCCO NOTES ON A6. HIGH RIB | | | METAL LATH IS REQUIRED TO BE FASTENED AT | | | EACH RIB (4"O.C.) PER ASTM C 1063. SEE | | | FBC 2504.2.2. | | | | | | 4) SUBMIT A LINTEL SCHEDULE. | | | | | | 5) SUBMIT THE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE ONE HOUR | | | FIRE RATED GLASS BLOCK. | | | | | | 6) PROVIDE (2) PRODUCT APPROVALS, KEY | | | PLANS AND INSTALLATION SCHEDULES | | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | | TO BE USED FOR STORM PANELS. INDICATE | | | INSTALLATION TYPE AND CONNECTION TYPE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-05 |
Time |
13:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-08-13 |
Time |
17:33 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-08 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-08 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2003-09-08 00:00:00 | TO RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-05 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-05 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-05 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-01 |
Time |
10:29 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-13 |
Time |
18:18 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-08-20 |
Time |
13:01 |
Sent To |
P |
|
| Notes |
| 2003-08-20 00:00:00 | PROVISO: | | | | | | 1.BALANCE AIR RETURN - RETURN TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM IT'S SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | 2.BATHROOMS SHALL HAVE A WINDOW WITH A | | | MINIMUM OF 3 SQ FT CLEAR OPENING OR HAVE | | | MECHANICAL VENTILATION. 2001 FBC(M) | | | 402.3.1 (REV JUNE 30,2003). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-20 |
Time |
13:09 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2003-08-20 |
Time |
19:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-01 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|