Plan Review Details - Permit 03072131
Plan Review Stops For Permit 03072131
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-09-25 Cont ID  
Sent By btrobaug Date 2003-09-25 Time 10:19 Rev Time 0.50
Received By lsmith Date 2003-09-25 Time 10:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-09-25 Cont ID  
Sent By kstevens Date 2003-09-24 Time 12:07 Rev Time 0.33
Received By btrobaug Date 2003-09-25 Time 10:08 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-16 Time 14:17 Rev Time 0.00
Received By csiegber Date 2003-09-16 Time 14:17 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-07 Cont ID  
Sent By alange Date 2003-08-07 Time 13:09 Rev Time 0.00
Received By alange Date 2003-08-07 Time 13:09 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-28 Cont ID  
Sent By alange Date 2003-07-28 Time 16:05 Rev Time 0.00
Received By alange Date 2003-07-28 Time 16:05 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-10-30 Cont ID  
Sent By kstevens Date 2003-10-30 Time 11:47 Rev Time 0.50
Received By kstevens Date 2003-10-30 Time 11:47 Sent To  
Notes
2003-10-30 00:00:00THIS POOL WAS STARTED UNDER THE 97 BLDG.
 CODE AND CONTRACTOR (CHALLENGER) WENT
 OUT OF BUSINESS. PER BUILDING OFFICIAL,
 THE POOL CAN BE FINISHED ON OLD CODE
 WITH THE EXCEPTION OF A VENT LINE TIED
 INTO MAIN DRAIN LINE AT LOW POINT AS THE
 LINE COMES OUT FROM UNDER THE POOL
 STRUCTURE. PURPLE PRIMER REQUIRED ON ANY
 NEW PVC - BACKFLOW REQURED PER LOCAL ORD
 2853-95

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-24 Cont ID  
Sent By mmclean Date 2003-09-22 Time 14:36 Rev Time 1.50
Received By kstevens Date 2003-09-23 Time 18:45 Sent To E
Notes
2003-09-24 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 6) 61G15-23.002(2) ENGINEERS SHALL LEGI-
 BLY INDICATE THEIR NAME, ADDRESS, AND
 LICENSE NUMBER ON EACH SHEET. NO LICENSE
 NUMBER SHOWN.
 7) PIPING SCHEMATIC DOES NOT REFLECT THE
 POOL LAYOUT. LAYOUT DOES NOT HAVE A
 CLEANING LINE, 4 MAIN DRAINS, VENTS, SPA
 JETS, FOUNTAIN OR HEATER.
 8) DRAIN DETAIL DOES NOT REFLECT THE
 POOL LAYOUT. ONLY ONE DRAIN SHOWN ON THE
 POOL LAYOUT. ALSO SHOW WHERE THE VENT IS
 CONNECTED.
 9) INDICATE SIZE OF MAIN DRAIN.
 10) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2003-09-22 Cont ID  
Sent By mmclean Date 2003-09-22 Time 14:36 Rev Time 0.00
Received By mmclean Date   Time   Sent To P
Notes
2003-09-22 00:00:009/22/03 OK PER SHIRLEY GRAHAM ASSOC
 PLANNER9/16/03/NO FOUNTAIN BEING ADDED M

Review Stop Z ZONING
Rev No 2 Status F Date 2003-08-26 Cont ID  
Sent By csiegber Date 2003-09-16 Time 14:17 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-08-26 00:00:008/26/03 DENIED, NEED TO BE 5FT FROM
 SIDE YARD CALLED LEFT MSG ON VOICE MAIL
 FIE C MM

Review Stop Z ZONING
Rev No 1 Status F Date 2003-07-30 Cont ID  
Sent By alange Date 2003-08-07 Time 13:09 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-07-30 00:00:007/30/03 DENIED, NEED TO BE 5'FT SIDE
 YARD CALLED CONTR FILE C MM