| Plan Review Stops For Permit 03072070 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-14 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-14 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2003-08-14 00:00:00 | PROVISO | | | | | | PLEASE SUBMIT THE FOLLOWING: | | | ALL ENGINEERS SEALS TO HAVE A HAND | | | SIGNED SIGNATURE NOT STAMPED SEE SEC. | | | 471.025 OF THE FLORIDA STATUES | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-11 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-11 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | ITEMS REQUIRED FOR REVIEW: | | | 1) DETAIL OF HEADER OVER FIXED GLASS | | | 2) 2 X 12 HEADER CALCULATIONS REQUIRED. | | | 3) LOCATE CUTS ON PLAN. | | | 4) WHAT IS THE HEIGHT OF THE WINDOW SILL | | | FROM FLOOR AT SECOND LEVEL? | | | | | | ART LANGEBUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPT. | | | CALL ME IF YOU HAVE ANY QUESTIONS | | | 561-805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-14 |
Time |
06:08 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-14 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2003-08-14 00:00:00 | *********** PROVISO/ REVISION ******** | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS FOR NEW WORK AND CORRELATE WITH | | | THE SUBMITTED PANEL SCHEDULE. | | | NOTE: 700.12E *** | | | PLEASE NOTE, THIS WAS REQUESTED ON ORIG | | | REVIEW. PLEASE SUBMIT BEFORE ROUGH | | | ELECTRICAL INSPECTION IS CALLED IN. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
13:06 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-01 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2003-08-01 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE CLARIFY NEW OR EXISTING | | | LIGHTING FOR NEW ROOMS AND EGRESS LIGHT- | | | -ING ON STAIRS AND EXITS. EM LTS ETC. | | | LS 101, CHAPT 5-8 SOME SHOWN, SEE FIRE | | | REVIEW COMMENTS FOR ANY ADDITIONAL REQ'D | | | 2)NOTE: PLEASE SHOW ALL NEW ELECTRICAL | | | CIRCUITING AND CORRELATE W/ A SUBMITTED | | | PANEL SCHEDULE. | | | | | | 2)NOTE: PLEASE SEE 600.5 FOR NEW OR | | | EXSITING SIGN CIRCUIT? BLDG USE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-08-14 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-08-14 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2003-08-14 00:00:00 | APPROVED PROVISO: ENSURE EXIT SIGNS | | | AND EMERGENCY LIGHTS ARE PROVIDED. | | | ENSURE EMERGENCY LIGHTS ARE PRESENT | | | WITHIN THE STAIRS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-12 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-12 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | 1) PLEASE REF NFPA 101 LIFE SAFETY CODE | | | 2000 EDITION CH. 38 BUSINESS OCCUPANCIES | | | | | | 2) EMERGENCY LIGHTING FOR STAIRS ARE NOT | | | SHOWN OR EXIT SIGNS. | | | | | | 3) PLEASE REF CH 38.3.3.2 FOR INTERIOR | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 4) SEPARATE PLAN AND PERMIT APPLICATION | | | ARE REQUIRED FOR FIRE SPRINKLER REMODEL. | | | | | | 5) SEPARATE PLAN AND PERMIT APPLICATION | | | ARE REQUIRED FOR FIRE ALARM SYSTEM | | | REMODEL. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-13 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2003-08-13 00:00:00 | TO COMM BD. 20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-12 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-12 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-29 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-29 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | COMM BOX #61 |
|
|