Plan Review Details - Permit 03072020
Plan Review Stops For Permit 03072020
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-01-13 Cont ID  
Sent By shill Date 2004-01-13 Time 12:11 Rev Time 3.00
Received By shill Date 2004-01-13 Time 12:10 Sent To  
Notes
2004-01-13 00:00:00REVISION - ALTERNATE FOOTING

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-11-29 Cont ID  
Sent By sthyng Date 2003-11-29 Time 11:58 Rev Time 1.00
Received By sthyng Date 2003-11-29 Time 11:58 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-10-29 Cont ID  
Sent By sthyng Date 2003-10-29 Time 09:59 Rev Time 1.00
Received By sthyng Date 2003-10-29 Time 09:59 Sent To  
Notes
2003-10-29 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 3.)ENERGY CALCS REQUIRED, FBC13-101.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-13 Cont ID  
Sent By kstevens Date 2003-10-28 Time 12:44 Rev Time 2.00
Received By sthyng Date 2003-08-13 Time 15:45 Sent To  
Notes
2003-08-13 00:00:00******CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 3.)PROVIDE AREA CALCULATIONS ON THE
 PLAN.
  
 4.)NOTE #1, BOTTOM OF THE FOUNDATION
 IS SHOWN AS 8" BELOW GRADE; FBC1804.1.3
 REQUIRES THE BOTTOM OF FOUNDATIONS TO
 EXTEND NO LESS THAN 12" BELOW FINISH
 GRADE.
  
 5.)ENERGY CALCS REQUIRED, FBC13-101.2.
  
 6.)HAVE AN ENGINEER CERTIFY THE
 STRUCTURAL DESIGN.
  
 7.)AT THE LAUNDRY ROOM, THERE IS A
 NOTE TO "REUSE EXISTING 2668 DOOR". TO
 REUSE THE DOOR, TWO COPIES OF A PRODUCT
 APPROVAL OR TEST REPORT FOR THAT DOOR
 MUST BE PROVIDED.
  
 8.)VENTILATION REQUIRED FOR CRAWL
 SPACE TO COMPLY WITH FBC1804.6.3.
  
 9.)PROVIDE UPLIFT FOR THE ATTACHMENTS.
  
 10.) PROVIDE DESIGN INFORMATION
 REQUIRED TO BE ON THE PLAN FBC1606.1.7.
  
 11.) IMPACT PROTECTION REQUIRED FOR
 GLAZING, FBC1606.1.4.
  
 12.)THE PLAN SHOWS THAT THE ROOF IS
 TO BE REPLACED WITH TILE.PROVIDE AN
 ENGINEER'S LETTER CERTIFYING THAT THE
 TRUSSES CAN ACCOMODATE THE ADDITIONAL
 LOAD.
  
 13.)FLOOR JOISTS TO COMPLY WITH FBC
 2304.3.4 (PRESSURE TREATED).
  
 14.)FIRESTOP REQUIRED, FBC705.3 (ALL
 WALLS AND PARTITION WALLS).
  
 15.)THE NEW GALLERY BLOCKS THE ONLY
 EMERGENCY EGRESS FOR THE ADJACENT
 BEDROOM.SLEEPING ROOMS ARE REQUIRED
 TO COMPLY WITH FBC1005.4.PLEASE
 ADDRESS.
  
 16.)PROVIDE TWO COPIES OF PRODUCT
 APPROVALS FOR:
 2668 DOOR
 2668 FRENCH DOOR
 SINGLE HUNG WINDOW
 ROOF TILE
 ROOF SHINGLES
 IMPACT PROTECTION

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-04 Cont ID  
Sent By alange Date 2003-07-30 Time 15:06 Rev Time 0.33
Received By btrobaug Date 2003-08-04 Time 08:54 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-22 Cont ID  
Sent By csiegber Date 2003-10-22 Time 11:59 Rev Time 0.00
Received By csiegber Date 2003-10-22 Time 11:59 Sent To P
Notes
2003-10-22 00:00:00TO KS DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-30 Time 15:06 Rev Time 0.00
Received By alange Date 2003-07-30 Time 15:06 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-25 Cont ID  
Sent By alange Date 2003-07-25 Time 16:40 Rev Time 0.00
Received By alange Date 2003-07-25 Time 16:40 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-08-09 Cont ID  
Sent By kstevens Date 2003-08-05 Time 09:31 Rev Time 0.50
Received By hmoser Date 2003-08-09 Time 13:51 Sent To B
Notes
2003-08-09 00:00:00NO MECHANICAL PLANS

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-12-03 Cont ID  
Sent By sthyng Date 2003-12-03 Time 17:24 Rev Time 0.00
Received By sthyng Date 2003-12-03 Time 17:24 Sent To  
Notes
2003-12-03 00:00:00OK PER PS

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-10-28 Cont ID  
Sent By sthyng Date 2003-11-29 Time 11:58 Rev Time 0.25
Received By kstevens Date 2003-10-28 Time 12:37 Sent To B
Notes
2003-10-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1) COMMENT FROM FIRST REVIEW NOT ADD-
 RESSED. ALL INFORMATION, DRAWINGS, SPEC-
 IFICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE PER-
 SON RESPONSIBLE FOR THE DESIGN. SECTION
 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-08-05 Cont ID  
Sent By csiegber Date 2003-10-22 Time 11:59 Rev Time 0.25
Received By kstevens Date 2003-08-05 Time 09:31 Sent To M
Notes
2003-08-05 00:00:00DENIED
 REFERENCE: FBC-2001 AMENDMENTS, CHAPTER
 ONE, ADMINISTRATION & AMEND.
  
 1) ALL INFORMATION, DRAWINGS, SPECIFICA-
 TIONS AND ACCOMPANYING DATA SHALL BEAR
 THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DISIGN. SECTION
 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-25 Time 16:40 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
***NONE***