| Plan Review Stops For Permit 03072020 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-13 |
Time |
12:11 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2004-01-13 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | REVISION - ALTERNATE FOOTING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-11-29 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-29 |
Time |
11:58 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-11-29 |
Time |
11:58 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-10-29 |
Time |
09:59 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-10-29 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.)ENERGY CALCS REQUIRED, FBC13-101.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-28 |
Time |
12:44 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-08-13 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2003-08-13 00:00:00 | ******CORRECTIONS******* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.)PROVIDE AREA CALCULATIONS ON THE | | | PLAN. | | | | | | 4.)NOTE #1, BOTTOM OF THE FOUNDATION | | | IS SHOWN AS 8" BELOW GRADE; FBC1804.1.3 | | | REQUIRES THE BOTTOM OF FOUNDATIONS TO | | | EXTEND NO LESS THAN 12" BELOW FINISH | | | GRADE. | | | | | | 5.)ENERGY CALCS REQUIRED, FBC13-101.2. | | | | | | 6.)HAVE AN ENGINEER CERTIFY THE | | | STRUCTURAL DESIGN. | | | | | | 7.)AT THE LAUNDRY ROOM, THERE IS A | | | NOTE TO "REUSE EXISTING 2668 DOOR". TO | | | REUSE THE DOOR, TWO COPIES OF A PRODUCT | | | APPROVAL OR TEST REPORT FOR THAT DOOR | | | MUST BE PROVIDED. | | | | | | 8.)VENTILATION REQUIRED FOR CRAWL | | | SPACE TO COMPLY WITH FBC1804.6.3. | | | | | | 9.)PROVIDE UPLIFT FOR THE ATTACHMENTS. | | | | | | 10.) PROVIDE DESIGN INFORMATION | | | REQUIRED TO BE ON THE PLAN FBC1606.1.7. | | | | | | 11.) IMPACT PROTECTION REQUIRED FOR | | | GLAZING, FBC1606.1.4. | | | | | | 12.)THE PLAN SHOWS THAT THE ROOF IS | | | TO BE REPLACED WITH TILE.PROVIDE AN | | | ENGINEER'S LETTER CERTIFYING THAT THE | | | TRUSSES CAN ACCOMODATE THE ADDITIONAL | | | LOAD. | | | | | | 13.)FLOOR JOISTS TO COMPLY WITH FBC | | | 2304.3.4 (PRESSURE TREATED). | | | | | | 14.)FIRESTOP REQUIRED, FBC705.3 (ALL | | | WALLS AND PARTITION WALLS). | | | | | | 15.)THE NEW GALLERY BLOCKS THE ONLY | | | EMERGENCY EGRESS FOR THE ADJACENT | | | BEDROOM.SLEEPING ROOMS ARE REQUIRED | | | TO COMPLY WITH FBC1005.4.PLEASE | | | ADDRESS. | | | | | | 16.)PROVIDE TWO COPIES OF PRODUCT | | | APPROVALS FOR: | | | 2668 DOOR | | | 2668 FRENCH DOOR | | | SINGLE HUNG WINDOW | | | ROOF TILE | | | ROOF SHINGLES | | | IMPACT PROTECTION |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
15:06 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-08-04 |
Time |
08:54 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
11:59 |
Sent To |
P |
|
| Notes |
| 2003-10-22 00:00:00 | TO KS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-30 |
Time |
15:06 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-25 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-25 |
Time |
16:40 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-05 |
Time |
09:31 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-08-09 |
Time |
13:51 |
Sent To |
B |
|
| Notes |
| 2003-08-09 00:00:00 | NO MECHANICAL PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-12-03 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-12-03 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2003-12-03 00:00:00 | OK PER PS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-29 |
Time |
11:58 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-28 |
Time |
12:37 |
Sent To |
B |
|
| Notes |
| 2003-10-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) COMMENT FROM FIRST REVIEW NOT ADD- | | | RESSED. ALL INFORMATION, DRAWINGS, SPEC- | | | IFICATIONS AND ACCOMPANYING DATA SHALL | | | BEAR THE NAME AND SIGNATURE OF THE PER- | | | SON RESPONSIBLE FOR THE DESIGN. SECTION | | | 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
11:59 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-08-05 |
Time |
09:31 |
Sent To |
M |
|
| Notes |
| 2003-08-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 AMENDMENTS, CHAPTER | | | ONE, ADMINISTRATION & AMEND. | | | | | | 1) ALL INFORMATION, DRAWINGS, SPECIFICA- | | | TIONS AND ACCOMPANYING DATA SHALL BEAR | | | THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DISIGN. SECTION | | | 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-25 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|