Plan Review Details - Permit 03072019
| Plan Review Stops For Permit 03072019 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-07 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-07 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FL ADMIN. CODE 61G15-23.002THE | | | CERTIFICATE OF AUTHORIZATION NUMBER OF | | | THE ENGINEERING BUSINESS (OR THE PRINTED | | | NAME, ADDRESS AND LICENSE NUMBER OF THE | | | ENGINEER) SHALL APPEAR ON THE TITLE | | | BLOCK OF EAC SHEET. | | | | | | 2) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 3) SUBMIT TWO COPIES OF A PRODUCT | | | APPROVAL FOR THE NEW EXTERIOR ALUMINUM | | | DOORS TO THE MECHANICAL ROOM.THE | | | PRODUCT APPROVAL DOCUMENTS SHALL BE | | | MARKED TO SHOW WHICH SIZE, COMPONENTS | | | AND CONFIGURATION WILL BE USED. | | | | | | 4) SUBMIT TWO COPIES OF A PRODUCT | | | APPROVAL FOR THE PROPOSED ROOF COVERING | | | SYSTEM.THE PRODUCT APPROVAL DOCUMENTS | | | SHALL BE MARKED TO SHOW WHICH SYSTEM | | | COMPONENTS AND CONFIGURATION WILL BE | | | USED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-05 |
Time |
14:11 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-08-05 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2003-08-05 00:00:00 | ********** UNSAT ******************** | | | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | | FOR KNOX BOX LOCATION. PLEASE INCLUDE | | | NOTE FOR SIGNAGE FOR SERVICE MEANS OF | | | DISC. 230.2 | | | | | | 2)NOTE: PLEASE SEE ATTACHED COPY OF | | | FS/ FAC 61G15-23.002 FOR REQ'Q MISSING | | | INFORMATION ON TITLE BLOCK FOR ENGINEER | | | OF RECORD. 471 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-11 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-11 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | THE KNOX-BOX NEED TO BE RELOCATED TO THE | | | FRONT OF THE BUILDING. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-29 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-29 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | TO COMM BD #38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-25 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-25 |
Time |
13:05 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-04 |
Time |
09:28 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2003-08-04 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-04 |
Time |
16:53 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-08-04 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2003-08-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) CONTACT RODNEY COMPO, INDUSTRIAL PRE- | | | TREATMENT, ENVIRONMENTAL COMPLIANCE TO | | | SIZE GREASE INTERCEPTOR. (561) 837-4074 | | | 2) SEPARATE PERMIT REQUIRED FOR GREASE | | | INTERCEPTOR.WASTE ORD #2938-96 | | | 3) SEPARATE GAS PERMIT REQUIRED. | | | 4) SHT P-2 #7, CONDENSATE TO HAVE A | | | RELIEF VENT AS IT EXITS THE BLDG. | | | 5) SHT P-2 #13 NO TRAPS IN THE RELIEF | | | VALVE DISCHARGE LINE. 504.7.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-04 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-08-04 00:00:00 | APPROVED UNDER PERMIT 03072026 BY S. | | | GRAHAM |
|
|
|