| Plan Review Stops For Permit 03072014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-26 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-09-29 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-08-11 |
Time |
14:53 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-08-11 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03072014 | | | ADD: 4055 N HAVERHILL RD | | | CONT:WAYNE DEVELOPMENT CORP | | | TEL: (954)650-5810 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) 1025.2 LOCKS(1) A SIGN IS READILY VIS | | | IBLE DUABLE SIGN ON OR ADJACENT TO THE | | | DOOR STATING: THIS DOOR TO REMAIN UNLOCK | | | ED WHEN THIS BUILDING IS OCCUPIED. | | | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THE PLAN INDICATES A NEW ROOM, SINCE | | | THE OCCUPANCY IS MERCANTILE, IF USED AS | | | A FITTING OR DRESSING ROOM MUST COMPLY | | | WITH 11-4.35(1-5). | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-26 |
Time |
15:34 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-09-26 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2003-09-26 00:00:00 | PLANS SENT TO LEA SMITH TO PROCESS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:11 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-08 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | *************UNSAT **************** | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW. | | | IT APPEARS THAT ONLY NOTE#1 WAS ADDRESS- | | | ED? | | | | | | PLEASE SEE ORIG NOTES ATTACHED. | | | | | | PLEASE SUBMIT INFORMATION FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-01 |
Time |
06:16 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-01 |
Time |
06:16 |
Sent To |
|
|
| Notes |
| 2003-08-01 00:00:00 | ********** UNSAT ******************** | | | | | | 1)NOTE: PLEASE PROVIDE ALL LICENSE | | | INFORMATION ON TITLE BLOCK AS REQ'D | | | UNDER FS-471, 61G15-23.004. | | | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS | | | SERVICE TO BE NEW? NO NOTES IF ALL | | | EXISTING? | | | | | | 3)NOTE: PLEASE SEE ALL SERVICE CONDUCTOR | | | -S.??350MCM FOR 600A'S, #1'S FOR 200A | | | MAIN DISC'S? PLEASE SIZE AND SHOW PER | | | 310.16 | | | 350MCM MENTIONS IN ONE 3' CONDCUIT? IS | | | THIS MEANT TO BE 2-3" CONDUITS? | | | | | | IT APPEARS THESE MUST BE MISPRINTS. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-29 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-29 |
Time |
17:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-23 |
Time |
16:11 |
Sent To |
E |
|
| Notes |
| 2003-09-23 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-27 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | TO COMM BD #9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-01 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-28 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2003-07-28 00:00:00 | TO COMM BD # 24 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-12 |
Time |
07:14 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-08-12 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | HVAC EXISTING AS PER NOTE ON A-1. | | | SEPARATE PERMIT REQUIRED SHOULD ANY | | | HVAC WORK BE DONE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-12 |
Time |
07:14 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-08-12 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | PLUMBING EXISTING - NO CHANGE PER NOTE | | | ON PLAN SHEET A-1 |
|
|