Plan Review Details - Permit 03071965
Plan Review Stops For Permit 03071965
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By rmcdouga Date 2003-09-17 Time 13:44 Rev Time 2.00
Received By rmcdouga Date 2003-09-17 Time 13:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-18 Cont ID  
Sent By csiegber Date 2003-09-11 Time 16:38 Rev Time 3.00
Received By rmcdouga Date 2003-08-18 Time 14:07 Sent To  
Notes
2003-08-18 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) INDICATE HOW ACCESS TO ATTIC WILL BE
 PROVIDED AS REQUIRED BY FBC 2309.6.
  
 3) FBC 1707.4.4.2 REQUIRES THAT THE 1X
 BUCK EXTEND PAST THE INTERIOR FACE OF
 THE FRAME TO PROVIDE FULL SUPPORT.PLEASE
 REVISE WINDOW BUCK DETAIL A ON A2.
  
 4) FBC 1609.4.3 NO LONGER ALLOWS THE
 ONE-THIRD INCREASE IN THE STEEL
 CALCULATIONS. PLEASE REVISE THE TRUSS
 ANCHOR SCHEDULE ON A3 TO VALUES THAT DO
 NOT INCLUDE THIS INCREASE. SEE THE 2003
 "USP" CATALOG.
  
 5) THE POSITIVE AND NEGATIVE WINDLOAD
 PRESSURES ARE NOT SPECIFIED ON THE PLAN
 FOR THE BRKFST ROOM WINDOWS AND THE
 SLIDING GLASS DOOR IN THE FAMILY ROOM.
  
 6) PROVIDE A LINTEL SCHEDULE.
  
 7) THE GLASS BLOCK AT THE MASTER BATH
 TUB IS IN A HAZARDOUS LOCATION AND IS
 REQUIRED TO HAVE A MINIMUM UNIFORM FACE
 THICKNESS ON 0.25" PER FBC 2405.2.2.
 PLEASE SPECIFY THIS ON PLANS.
  
 8) THE OWNER/AGENT IS REQUIRED TO SIGN
 THE ENERGY CALC. FORM. FBC 13-103
  
 9) THE PRODUCT APPROVAL FOR THE SLIDING
 GLASS DOOR IS FOR THE OXXO CONFIGURATION
 ONLY AND DOES NOT COVER THE TWO PANEL
 DOOR SHOWN ON THE PLANS. PLEASE SUBMIT
 THE APPROPRIATE PRODUCT APPROVAL.
  
 10) PLEASE SUBMIT LEGIBLE COPIES OF THE
 PRODUCT APPROVALS FOR THE GLASS BLOCK.
  
 11) PLEASE SUBMIT MANUFACTURER'S SPECS.
 AND UL LISTING INFORMATION FOR THE GAS
 BBQ.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-08-23 Cont ID  
Sent By btrobaug Date 2004-08-23 Time 15:41 Rev Time 0.50
Received By btrobaug Date 2004-08-23 Time 15:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-06 Cont ID  
Sent By btrobaug Date 2004-08-06 Time 12:55 Rev Time 0.50
Received By btrobaug Date 2004-08-06 Time 12:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-05 Cont ID  
Sent By csiegber Date 2004-08-05 Time 13:38 Rev Time 0.50
Received By btrobaug Date 2003-08-05 Time 11:01 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-05 Cont ID  
Sent By csiegber Date 2004-08-05 Time 13:38 Rev Time 0.00
Received By csiegber Date 2004-08-05 Time 13:38 Sent To E
Notes
2004-08-05 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-11 Cont ID  
Sent By csiegber Date 2003-09-11 Time 16:38 Rev Time 0.00
Received By csiegber Date 2003-09-11 Time 16:38 Sent To B
Notes
2003-09-11 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-30 Time 16:01 Rev Time 0.00
Received By alange Date 2003-07-30 Time 16:01 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-24 Cont ID  
Sent By mmclean Date 2003-07-30 Time 12:25 Rev Time 0.00
Received By alange Date 2003-07-24 Time 16:20 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-12 Cont ID  
Sent By btrobaug Date 2003-08-05 Time 11:52 Rev Time 0.25
Received By pkrauss Date 2003-08-12 Time 06:22 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-09-01 Cont ID  
Sent By kstevens Date 2004-09-01 Time 13:25 Rev Time 2.00
Received By kstevens Date 2004-08-27 Time 10:03 Sent To  
Notes
2004-09-01 00:00:00REVISION DENIED
  
 REVISIONS TO A SIGNED/SEALED SET OF
 PLANS SHALL BE SIGNED/SEALED/DATED BY
 THE ENGINEER/ARCHITECT OF RECORD.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-14 Cont ID  
Sent By pkrauss Date 2003-08-12 Time 06:22 Rev Time 0.33
Received By jleech Date 2003-08-14 Time 18:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-24 Time 16:21 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***