Plan Review Details - Permit 03071940
Plan Review Stops For Permit 03071940
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By jwitmer Date 2003-09-17 Time 07:09 Rev Time 0.55
Received By jwitmer Date 2003-09-17 Time 07:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-11 Cont ID  
Sent By csiegber Date 2003-09-16 Time 10:23 Rev Time 1.25
Received By jwitmer Date 2003-08-11 Time 15:24 Sent To  
Notes
2003-08-11 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 03071940
 ADD: 4200 BEAR LAKES COURT
 CONT: ALLIANCE CONSTRUCTION
 TEL: (305)345-2029
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 DUMPSTER
 ACTION: DENIED
  
 1)11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENTRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
  
 2)11-4.1.3(3) GROUND & FLOOR SURFACES
 ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE
 ROOMS & SPACES SHALL COMPLY WITH
 11-4.5. SEE ADDAAG A4.5.1 (GUIDELINE)
 A STATIC COEFFICIENT OF FRICTION OF 0.6
 IS RECOMENDED FOR ACCESSIBLE ROUTES
 AND 0.8 FOR RAMPS.
  
 3)11-4.8.3. CLEAR WIDTH. THE MINIMUM
 CLEAR WIDTH OF A RAMP SHALL BE 36".
 EXCEPTION: RAMPS THAT ARE PART OF A
 REQUIRED MEANS OF EGRESS SHALL NOT BE
 LESS THAN 44 INCHES WIDE.
  
 4)11-4.8.4(3) IF RAMPS CHANGE DIREC-
 TION AT LANDINGS, THE MINIMUM LANDING
 SIZE SHALL BE 60" X 60".
  
 5)11-4.3.3 WIDTH. THE MINIMUM CLEAR
 WIDTH OF AN ACCESSIBLE ROUTE SHALL BE
 36" EXCEPT AT DOORS. IF A PERSON IN A
 WHEELCHAIR MUST TURN AROUND AN OBSTRUC-
 TION, THE MINIMUM CLEAR WIDTH OF THE
 ACCESSIBLE ROUTE SHALL BE SHOWN IN
 FIGURE 7(A) AND (B).FL ACCESSIBILITY
  
  
 6) 11-4.1.3(15) DETECTABLE WARNING AS
 11-4.29.2 (1)(2) SEE ANSI 117.705.1
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-22 Cont ID  
Sent By dpalmer Date 2003-09-22 Time 17:07 Rev Time 1.50
Received By dpalmer Date 2003-09-22 Time 17:07 Sent To  
Notes
2003-09-22 00:00:00*********** REVISION/PROVISO *********
  
 REDLINED SERVICE ENTRANCE CONTS. SHOWN
 AS 3-PHASE SERVICE AND ONLY SINGLE PHASE
 COMING INTO METER??
  
 REVISE PLANS AND SUBMIT FOR REVIEW
 BEFORE ROUGH ELECTRICAL INSPECTION.
 IF THERE ARE ANY QUESTIONS,PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
 PLANS WENT BACK TO BOARD, NEEDS PLUMB
 REVIEW, NEVER WENT TO PLUMB.
 IF THERE ARE PLUMB COMMENTS, ELECTRICAL
 PROVISO WILL BE CHANGED TO FAIL AND
 REDLINED ITEM WILL NEED TO BE ADDRESSED.
 REDLINED TWICE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-01 Cont ID  
Sent By dpalmer Date 2003-08-01 Time 06:08 Rev Time 0.25
Received By dpalmer Date 2003-08-01 Time 06:07 Sent To  
Notes
2003-08-01 00:00:00REDLINED SERVICE ENT CONDUCTORS, NOT
 SHOWN FOR 3-PHASE AND SERVICE IS SHOWN
 AT 3-PHASE.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2003-09-17 Cont ID  
Sent By mamini Date 2003-09-17 Time 15:33 Rev Time 0.50
Received By mamini Date 2003-09-17 Time 15:32 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-08-01 Cont ID  
Sent By dbaxter Date 2003-08-29 Time 14:21 Rev Time 0.50
Received By mamini Date 2003-08-01 Time 10:30 Sent To  
Notes
2003-08-01 00:00:00FAILED:
 1. A GREASE/WATER SEPARATOR IN 3" FLOOR
 DRAIN PRIOR TO CONNECTING TO SEWER
 SYSTEM IS REQUIRED.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R.AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-09-16 Cont ID  
Sent By nmccray Date 2003-09-16 Time 16:01 Rev Time 0.00
Received By nmccray Date 2003-09-16 Time 16:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-16 Time 10:23 Rev Time 0.00
Received By csiegber Date 2003-09-16 Time 10:23 Sent To  
Notes
2003-09-16 00:00:00TO JW DESK
 ON COMM BD#41

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-29 Cont ID  
Sent By dbaxter Date 2003-08-29 Time 14:20 Rev Time 0.00
Received By dbaxter Date 2003-08-29 Time 14:20 Sent To ENG
Notes
2003-08-29 00:00:00TO MAMINI DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-30 Cont ID  
Sent By alange Date 2003-07-30 Time 15:40 Rev Time 0.00
Received By alange Date 2003-07-30 Time 15:39 Sent To  
Notes
2003-07-30 00:00:00TO COMM BD #23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-25 Cont ID  
Sent By mmclean Date 2003-07-29 Time 14:47 Rev Time 0.00
Received By alange Date 2003-07-25 Time 09:17 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-10-08 Cont ID  
Sent By kstevens Date 2003-10-08 Time 11:34 Rev Time 0.50
Received By kstevens Date 2003-10-08 Time 11:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-29 Cont ID  
Sent By alange Date 2003-07-25 Time 09:18 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***