Plan Review Details - Permit 03071724
Plan Review Stops For Permit 03071724
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2004-03-15 Cont ID  
Sent By shill Date 2004-03-15 Time 11:49 Rev Time 0.50
Received By shill Date 2004-03-15 Time 11:49 Sent To  
Notes
2004-03-15 00:00:00REVISION 3/15/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-03-09 Cont ID  
Sent By shill Date 2004-03-09 Time 11:42 Rev Time 0.50
Received By shill Date 2004-03-09 Time 11:42 Sent To  
Notes
2004-03-09 00:00:00REVISION - STRUCTURAL FRAMING DETAILS
 DATED 3/5/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-01-29 Cont ID  
Sent By shill Date 2004-01-29 Time 11:41 Rev Time 0.50
Received By shill Date 2004-01-29 Time 14:53 Sent To  
Notes
2004-01-29 00:00:00REVISION APPROVED - SEE LETTER IN FILE
 NKM REGARDING HISTORIC/EGRESS WINDOWS

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2003-12-29 Cont ID  
Sent By csiegber Date 2004-01-27 Time 12:47 Rev Time 1.00
Received By shill Date 2003-12-29 Time 12:17 Sent To  
Notes
2003-12-29 00:00:00ARCHITECT TO SUBMIT A LETTER TO
 BUILDING OFFICIAL REGARDING EGRESS
 ISSUE PER CONVERSATION W/ARCHITECT

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-12-01 Cont ID  
Sent By alange Date 2003-12-18 Time 15:04 Rev Time 1.00
Received By sthyng Date 2003-12-01 Time 10:20 Sent To  
Notes
2003-12-01 00:00:00*****CORRECTIONS*******
 REVISION
  
 1.)SUBMIT PRODUCT APPROVALS FOR
 THE FRENCH DOORS.
  
 2.)D-8.1, TWO RISERS + ONE TREAD
 SHOULD EQUAL 24"-25" (PLAN SAYS 35"),
 FBC1007.3.
  
 3.)BEDROOMS ARE REQUIRED TO HAVE
 EMERGENCY EGRESS, FBC1005.4.THE
 WINDOWS I AND A DO NOT COMPLY (PER
 PGT CODE COMPLIANCE DEPARTMENT).
  
 4.)E7.2, NEW RAILING MUST COMPLY WITH
 FBC1007.5, FBC1608.2.1.PROVIDE A
 DETAIL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-09-26 Cont ID  
Sent By btrobaug Date 2003-11-26 Time 15:05 Rev Time 0.50
Received By sthyng Date 2003-09-26 Time 09:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-09-25 Cont ID  
Sent By sthyng Date 2003-09-26 Time 09:41 Rev Time 2.50
Received By sthyng Date 2003-09-25 Time 09:38 Sent To  
Notes
2003-09-25 00:00:00IMPACT FEES
 PROVISO - SUBMIT PA FOR FRONT DOOR

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-09-16 Cont ID  
Sent By jleech Date 2003-09-24 Time 19:20 Rev Time 2.50
Received By sthyng Date 2003-09-16 Time 14:31 Sent To  
Notes
2003-09-16 00:00:00******CORRECTIONS********
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025.
  
 2.)TWO COPIES OF THE ENERGY CALCS
 MUST BE PROVIDED.
  
 3.)ENERGY CALC, PRESCRIPTIVE METHOD
 C, REQUIRES R30 MINIMUM INSULATION IN
 THE UNDER ATTIC SPACE.YOU SPECIFY R19
 ON THE ENERGY CALC (SEE THE BACK OF THE
 FORM FOR THE MINIMUM INSULATION).
 HOWEVER, THE ENTRY SECTION SHOWS THIS
 AREA AS A SINGLE ASSEMBLY.EITHER
 CHANGE THE ENERGY CALC TO REFLECT THE
 SINGLE ASSEMBLY OR CHANGE THE R19 TO
 R30 UNDER ATTIC AND REVISE A-8.1.
  
 4.)A PRODUCT APPROVAL IS REQUIRED FOR
 THE FRONT DOOR.THE PERMIT WILL BE
 ISSUED WITH A PROVISO TO SUBMITTHE
 PRODUCT APPROVAL BEFORE INSTALLATION.
  
 5.)A-8.1, NEW 2X10 FLOOR JOISTS, MUST
 COMPLY WITH FBC2304.3.4.
  
 6.)SIMPSON LU210 JOIST HANGER IS A
 WOOD-TO-WOOD CONNECTOR.A-8.1 SHOWS
 IT IN A MASONRY APPLICATION.
  
 7.)THE REVISED SHEETS MUST BE STAMPED
 BY THE HISTORIC PRESERVATION DEPARTMENT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-12 Cont ID  
Sent By kstevens Date 2003-09-06 Time 12:39 Rev Time 2.00
Received By sthyng Date 2003-08-12 Time 11:22 Sent To Z
Notes
2003-08-12 00:00:00*****CORRECTIONS******
  
 1.) SHEET 4.1, NOTES, REFERS TO FBC2000.
 SHOULD BE FBC2001.
  
 2.) ARE THE WINDOWS AT THE 2ND FLOOR
 BEDROOM TO BE REPLACED?IF THEY ARE,
 SHOW SIZE TO SHOW COMPLIANCE WITH
 FBC1005.4 (EGRESS).IF NOT, INDICATE
 AS EXISTING.
  
 3.)SHEET 4.1 REFERS TO SHEETS A17
 AND 9.1 (TYPICAL WOOD BUCK TO CONCRETE).
 SHEETS REFERRED TO ARE NOT A PART OF THE
 PLAN.
  
 4.)2ND FLOOR FRAMING PLAN APPEARS TO
 BE THE 1ST FLOOR.
  
 5.)A PRODUCT APPROVAL IS REQUIRED FOR
 THE FRONT DOOR.IF A TEST REPORT IS NOT
 AVAILABLE, YOU MAY SUBMIT A SITE
 SPECIFIC.THIS CAN BE SUBMITTED NOW
 OR THE PERMIT CAN BE ISSUED WITH A
 PROVISO THAT THE PRODUCT APPROVAL FOR
 THE FRONT DOOR BE SUBMITTED BEFORE
 INSTALLATION.
  
 6.)SEPARATE PERMITS REQUIRED FOR THE
 ROOF.SUBMIT PRODUCT APPROVAL WITH THE
 ROOF PERMIT APPLICATION.
  
 7.)AREA CALCULATIONS SHOULD SHOW
 EXISTING, PROPOSED, AND A NEW TOTAL.
  
 8.)ENERGY CALCS REQUIRED FBC13-101.2,
 UNLESS THIS IS A CONTRIBUTORY PROPERTY
 (HISTORIC) AS PER FBC3401.5.
  
 9.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-11-26 Cont ID  
Sent By btrobaug Date 2003-11-26 Time 15:05 Rev Time 0.50
Received By btrobaug Date 2003-11-21 Time 07:48 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-09-23 Cont ID  
Sent By csiegber Date 2003-11-20 Time 11:50 Rev Time 0.50
Received By btrobaug Date 2003-09-23 Time 11:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-17 Time 11:23 Rev Time 0.50
Received By btrobaug Date 2003-09-04 Time 08:14 Sent To P
Notes
2003-09-04 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION,MAKE NECESSARY CORRECTIONS
 ON THE PLANS AND RESUBMIT FOR REVIEW.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} THE PANEL SCHEDULE INDICATES PANEL
 "A" IS A 200 AMP MLO,THE RISER SHOWS
 PANEL "A" AS 150 AMP WITH A MAIN
 BREAKER.PLEASE CORRELATE.
  
 3} THE PANEL SCHEDULE SHOWS 2 SMALL
 APPLIANCE CIRCUITS,EACH ON A SINGLE
 POLE 20 WITH A LOAD OF 3KW,ON
 #12 WIRE.PLEASE CORRECT.
  
 4} THE GROUNDING ELECTRODE SYSTEM MUST
 COMPLY WITH ALL OF ARTICLE 250 THAT ARE
 AVAILABLE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-23 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:33 Rev Time 0.50
Received By btrobaug Date 2003-07-23 Time 16:41 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-01-27 Time 12:47 Rev Time 0.00
Received By csiegber Date 2004-01-27 Time 12:46 Sent To B
Notes
2004-01-27 00:00:00TO SH DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-12-18 Cont ID  
Sent By alange Date 2003-12-18 Time 15:04 Rev Time 0.00
Received By alange Date 2003-12-18 Time 15:04 Sent To B
Notes
2003-12-18 00:00:00TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-11-20 Cont ID  
Sent By csiegber Date 2003-11-20 Time 11:49 Rev Time 0.00
Received By csiegber Date 2003-11-20 Time 11:49 Sent To E
Notes
2003-11-20 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-26 Cont ID  
Sent By sthyng Date 2003-09-26 Time 09:41 Rev Time 0.00
Received By sthyng Date 2003-09-26 Time 09:41 Sent To B
Notes
2003-09-26 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-17 Cont ID  
Sent By csiegber Date 2003-09-17 Time 11:22 Rev Time 0.00
Received By csiegber Date 2003-09-17 Time 11:22 Sent To E
Notes
2003-09-17 00:00:00TO BT DESK/RESUB DRAWINGS/PLANS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-02 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:33 Rev Time 0.00
Received By csiegber Date 2003-09-02 Time 11:33 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-27 Cont ID  
Sent By mmclean Date 2003-09-02 Time 09:42 Rev Time 0.00
Received By csiegber Date 2003-08-27 Time 15:42 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-23 Cont ID  
Sent By alange Date 2003-07-23 Time 10:39 Rev Time 0.00
Received By alange Date 2003-07-23 Time 10:39 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-08-09 Cont ID  
Sent By kstevens Date 2003-09-06 Time 12:07 Rev Time 0.10
Received By pkrauss Date 2003-08-09 Time 08:17 Sent To B
Notes
2003-08-09 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-24 Cont ID  
Sent By jleech Date 2003-09-24 Time 19:20 Rev Time 0.50
Received By jleech Date 2003-09-24 Time 19:19 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-09-06 Cont ID  
Sent By btrobaug Date 2003-09-23 Time 11:53 Rev Time 0.50
Received By kstevens Date 2003-09-06 Time 12:06 Sent To B
Notes
2003-09-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA STATUTES
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS.
 A) PIPE SIZE NOT CORRECT. 1-1/2" TO W/M
 NOT APPROVED. ANY PORTION OF THE DRAIN-
 AGE SYSTEM INSTALLED UNDERGROUND SHALL
 NOT BE LESS THAN 2" IN DIAMETER. SECTION
 710.3. - THE SIZE OF THE DRAINAGE PIPING
 SHALL NOT BE REDUCED IN THE DIRECTION OF
 THE FLOW. SECTION 704.2 (W/M SHOWN FROM
 2" PIPE TO 1-1/2").
 B) 2ND FLOOR BATHROOM STILL DRAIN THRU
 THE DRAINAGE PIPING FOR THE FIRST FLOOR
 BATHROOM. THIS IS NOT ALLOWED. SECTION
 908.2.
 C) STANDPIPE REQUIRED AT WASH MACHINE
 SECTION 802.4
 D) CLEANOUT REQUIRED 4' ABOVE FLOOR AT
 WASH MACHINE. SECTION 708.10
 E) W/C AND SHOWER ARE NOT VENTED AT
 FIRST FLOOR BATHROOM. SECTION 901.2.1
 2) SHOWER ON SANITARY RISER DIAGRAM IS
 LABELED AS A FLOOR DRAIN.
 3) SEE RED LINE CORRECTIONS FROM THE 1ST
 REVIEW FOR A SANITARY RISER DIAGRAM THAT
 MEETS CODE REQUIREMENTS.
 4) SEE ATTACHED SHEET CONCERNING FLORIDA
 STATUTE 553.80(2)(B).
 ********WHEN RESUBMITTING PLANS*********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-29 Cont ID  
Sent By btrobaug Date 2003-09-04 Time 10:02 Rev Time 0.50
Received By kstevens Date 2003-07-29 Time 12:43 Sent To M
Notes
2003-07-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS.
 A) PIPE SIZES NOT CORRECT. 3" MINIMUM
 FOR WATER CLOSETS. TABLE 709.1
 B) 2" MINIMUM FOR ALL PIPING FOR SHOWER
 UNDERGROUND. SECTION 710.3
 C) 2ND FLOOR BATHROOM FIXTURES SHALL
 NOT DRAIN IN VENT FOR 1ST FLOOR BATHROOM
 SECTION 908.3
 D) LAV IN 1ST FLOOR BATHROOM NOT VENTED
 E) WASHMACHINE NOT VENTED PROPERLY. 2"
 STANDPIPE REQUIRED. CLEANOUT REQUIRED 4'
 ABOVE FLOOR.
 2) SEE RED LINE CORRECTIONS FOR PIPE
 SIZES AND ROUTING OF PIPING. CHANGE TO
 MEET CODE REQUIREMENTS AND RESUBMIT.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2003-09-02 Cont ID  
Sent By mmclean Date 2003-09-02 Time 09:42 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
2003-09-02 00:00:009/2/03 PASS ZONING OK FOR GRACE JOYCE MM

Review Stop Z ZONING
Rev No 1 Status F Date 2003-08-18 Cont ID  
Sent By csiegber Date 2003-08-27 Time 15:43 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-08-18 00:00:008/18/03 DENIED, SITE PLAN NOT DRAWN TO
 SCALE, CALLED OWNER/CONTR MM