| Plan Review Stops For Permit 03071487 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-26 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-25 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-07 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-16 |
Time |
06:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-16 |
Time |
06:31 |
Sent To |
|
|
| Notes |
| 2003-09-16 00:00:00 | ********** NOTES REDLINED ***** | | | | | | PLEASE SEE THAT AN EQUIPMENT GROUNDING | | | CONDUCTOR IS NOT INSTALLED FROM METER | | | TO MAIN DISCONNECT. 250.24 | | | | | | GFI CODE REFERENCE ON PLAN, SHOWS 210.88 | | | SHOULD BE 210.8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-26 |
Time |
06:49 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-08-25 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2003-08-26 00:00:00 | **************UNSAT *************** | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW, SOME | | | NOT COMPLETED.SOME NEW NOTES FROM PLANS | | | BEING CHANGED AND FROM RISER DIAGRAM | | | BEING SUBMITTED. | | | | | | 1)NOTE: PLEASE CLARIFY SIZING OF SERVICE | | | ENT CONDUCTORS FOR 200A SERVICE. SHOWN | | | AS 1/0`S PLEASE SEE 310.16. | | | | | | 2)NOTE: PLEASE CLARIFY HOW SUB PANEL IS | | | BEING FED? RISER SHOWS COMING FROM PANEL | | | 'A', YET PANEL "A" SCHEDULE DOES NOT | | | SHOW SUB PANEL/OCP FEEDING PANEL "B"?? | | | | | | 3)NOTE: PLEASE CLARIFY TWO ITEMS SHOWN | | | ON PANEL SCHEDULE "A" ,220A CIRCUIT? | | | ONE SHOWN WITH #10 AWG? PLEASE CLARIFY | | | WHAT THESE ARE? | | | | | | 4)NOTE: PLEASE CORRELATE ALL CIRCUITING | | | ON PLAN W/ PANEL SCHEDULE. PLEASE SEE | | | WATER HEATER?WH, SHOWN AS #6, YET | | | PANEL SCHEDULE SHOWS GEN LTS? | | | | | | 5)NOTE: PLEASE SEE 250.110 AND 250.122 | | | FOR MISSING EQUIPMENT GROUNDING CONDUCT- | | | OR FROM MAIN PANEL TO SUB-PANEL? | | | | | | 6)NOTE: PLEASE SEE 424.3B FOR SIZING | | | OF OCP FOR AHU. PLEASE ALSO SEE 310.16 | | | FOR AWG. | | | | | | 7)NOTE: PLEASE SEE 210.8B, 1,2,3 FOR | | | GFI PROTECTION REQ'D IN KITCHENS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
13:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-23 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CLARIFY CONFLICTING NOTES | | | ON PLANS. NOTE 6 MENTIONS TO CONNECT | | | NEW ELEC TO EXISITNG PANELS, HOWEVER | | | OTHER NOTES MENTION THAT BOTH PANELS | | | ARE BEING REPLACED? | | | PLEASE CORRELATE. | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE W/ A SUBMITTED PANEL | | | SCHEDULE. | | | PLEASE CIRCUIT EM/EXT LTS PER 700.12E | | | | | | 3)NOTE: PLEASE CLARIFY NEW/OR EXISTING | | | EGRESS LIGHTING OUTSIDE DOORWAYS. | | | LIFE SAFETY 101 5-8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-25 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-25 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2003-07-25 00:00:00 | 1) BUILDING ADDRESS AT LEAST 6" HIGH | | | REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-21 |
Time |
14:35 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-08 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-08 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | ON COMM BD#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-22 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-22 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2003-08-22 00:00:00 | TO COMM BD #5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-14 |
Time |
13:57 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-14 |
Time |
12:17 |
Sent To |
B |
|
| Notes |
| 2003-08-14 00:00:00 | TO HPISCURA DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-18 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-18 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2003-07-18 00:00:00 | COMM BOARD #7 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-02 |
Time |
10:58 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-02 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-21 |
Time |
14:36 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-08-28 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-11 |
Time |
13:13 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-08-11 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-16 |
Time |
09:12 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-09-16 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-09-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-06 |
Time |
20:19 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-09-06 |
Time |
20:19 |
Sent To |
|
|
| Notes |
| 2003-09-06 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | | | | FROM PREVIOUS REVIEW, SEE ATTACHED SHEET | | | CONCERNING 61G1-16.003. WHEN SEAL MAY BE | | | AFFIXED. NO DATE SHOWN WHEN PLANS WERE | | | SEALED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-07 |
Time |
14:58 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-08-07 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY AND WATER RISERS REQUIRED. | | | (ONLY FIXTURES FROM THE BATHROOM GROUP | | | TO DRAIN INTO THE HORIZONTAL BRANCH OF | | | THE WET VENT. OTHER SINKS SHALL TIE IN | | | DOWNSTREAM OF BATHROOM GROUP. 909.1) | | | 2) 61G1-16.003 DATE SHALL APPEAR ON ALL | | | SHEETE WITH SEAL AND SIGNATURE. (SEE | | | ATTACHED SHEET) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|