Plan Review Details - Permit 03071382
Plan Review Stops For Permit 03071382
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-12-29 Cont ID  
Sent By shill Date 2003-12-29 Time 11:14 Rev Time 0.50
Received By shill Date 2003-12-29 Time 11:14 Sent To  
Notes
2003-12-29 00:00:00LETTER, CHANGE 8X16 TO 8X14 BEAM

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-12-22 Time 12:27 Rev Time 0.50
Received By sthyng Date 2003-10-24 Time 13:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-10-21 Cont ID  
Sent By dpalmer Date 2003-10-24 Time 13:22 Rev Time 1.50
Received By sthyng Date 2003-10-21 Time 13:55 Sent To  
Notes
2003-10-21 00:00:00IMPACT FEES ONLY
  
 TO DP DESK - OLD APPROVED ELECTRIC
 SHEETS GONE
 OWNER TO BRING IN OLD SHEETS - BACK ON
 ST DESK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-09-19 Cont ID  
Sent By kstevens Date 2003-10-18 Time 09:18 Rev Time 1.00
Received By sthyng Date 2003-09-19 Time 11:07 Sent To  
Notes
2003-09-19 00:00:00******CORRECTIONS********
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)FEES DUE, $277.54, BZ231314.PAY
 AT CASHIER.
  
 2.)SEPARATE PERMITS REQUIRED.
  
 3.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY BEFORE A PERMIT CAN BE
 ISSUED.THE PLANS MUST BE STAMPED AND
 THE RECEIPT ATTACHED TO THE APPLICATION.
  
 4.)FILL OUT THE TOP PORTION OF THE
 ENERGY CALCS (PROJECT SECTION).
  
 5.)COMMENTS 6, 9, 10, 11, 12, 13 AND
 14 FROM THE PREVIOUS LIST WERE NOT
 ADDRESSED.THE SAME PLANS WERE
 SUBMITTED DATED 7/4/03 WITH NO REVISONS.
 SEE ATTACHED.
  
 6.)CLARIFY - WHY DID YOU SUBMIT A
 PRODUCT APPROVAL FOR AN EGRESS WINDOW
 WHEN THE SINGLE HUNG 245 MEETS THE
 EGRESS REQUIREMENTS FBC1005.4?PLEASE
 CALL ME IF YOU DO NOT UNDERSTAND THIS
 CORRECTION.
  
 7.)THE WINDOW PRODUCT APPROVAL IS NOT
 LEGIBLE OR COMPLETE.YOU MAY BE ABLE
 TO GET THIS ONLINE AT WWW.MIAMIDADE.GOV
 (FIND A DEPARTMENT, BUILDING CODE
 COMPLIANCE, PRODUCT CONTROL, SEARCH
 APPROVED PRODUCTS).
  
 8.)THE SBCCI REPORT FOR THE HURRICANE
 SHUTTERS IS NOT LEGIBLE.YOU MAY BE
 ABLE TO GET THIS ONLINE AT
 WWW.SBCCIES.ORG (TABLE OF CONTENTS,
 LISTED EVALUATION PRODUCTS).
  
 9.)PREVIOUS COMMENT NUMBER 9 NOT
 ADDRESSED.
  
 10.) SEE ATTACHED NOTICE IN REGARDS TO
 FS553.80(2)(B).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-11 Cont ID  
Sent By kstevens Date 2003-09-06 Time 19:45 Rev Time 2.50
Received By sthyng Date 2003-08-11 Time 14:18 Sent To  
Notes
2003-08-11 00:00:00******CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)ADDITIONAL FEES DUE (VALUE
 ADJUSTMENT, RADON).
  
 2.)AREA CALCS SHOW THE ADDITION AS A
 "NEW GARAGE".REVISE.
  
 3.)SEPARATE PERMITS REQUIRED.
  
 4.)BEFORE A PERMIT TO CONSTRUCT CAN
 BE ISSUED, A NOTICE OF COMMENCEMENT MUST
 BE FILED WITH THE CLERK OF COURTS.
  
 5.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 6.)ADDITIONS OF OVER 25% SHALL COMPLY
 WITH FBC3401.7.1.2, JULY 1 2003 AMEND.
 SHOW COMPLIANCE (GFIS, SMOKE DETECTORS).
  
 7.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 8.)SUBMIT TWO COPIES OF ALL PRODUCT
 APPROVALS.
 WINDOW
 IMPACT PROTECTION
 ROOF (OR MAY BE SUBMITTED WITH ROOF
 PERMIT APPLICATION)
  
 9.)PROVIDE A HURRICANE SHUTTER
 ATTACHMENT SCHEDULE, SEE ATTACHED.
  
 10.) SAFETY GLASS REQUIRED AT THE
 SHOWER, FBC2405.
  
 11.) THE WINDOW AND DOOR BUCK DETAIL
 MUST COMPLY WITH FBC1707.4.4.2.THE
 GRAPHIC DOES NOT SHOW FULL SUPPORT BY
 THE BUCK.
  
 12.)FOUNDATION PLAN SHOWS BOTH A 6"
 AND 8" EMBEDMENT INTO THE EXISTING.
  
 13.)WIND INFORMATION; INTERNAL
 PRESSURE COEFFICIENT SHOULD BE A NUMBER.
  
 14.)THE CURRENT CODE INCLUDES FBC
 2003 AMENDMENTS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-09 Cont ID  
Sent By dpalmer Date 2004-03-09 Time 12:01 Rev Time 0.33
Received By dpalmer Date 2004-03-09 Time 12:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-24 Cont ID  
Sent By csiegber Date 2004-03-04 Time 13:37 Rev Time 0.33
Received By dpalmer Date 2003-10-24 Time 13:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-24 Cont ID  
Sent By csiegber Date 2003-10-22 Time 11:10 Rev Time 0.33
Received By dpalmer Date 2003-07-24 Time 07:38 Sent To P
Notes
2003-07-24 00:00:00********* NOTE **********
  
 PLANS REDLINED 210.52D/210.11.C.3
 210.12

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-03-04 Cont ID  
Sent By csiegber Date 2004-03-04 Time 13:37 Rev Time 0.00
Received By csiegber Date 2004-03-04 Time 13:37 Sent To E
Notes
2004-03-04 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-12-22 Cont ID  
Sent By csiegber Date 2003-12-22 Time 12:27 Rev Time 0.00
Received By csiegber Date 2003-12-22 Time 12:27 Sent To B
Notes
2003-12-22 00:00:00TO ST DESK/REV BEAM SCHEDULE

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-10-22 Cont ID  
Sent By csiegber Date 2003-10-22 Time 11:06 Rev Time 0.00
Received By csiegber Date 2003-10-22 Time 11:06 Sent To E
Notes
2003-10-22 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-08 Cont ID  
Sent By csiegber Date 2003-10-08 Time 12:23 Rev Time 0.00
Received By csiegber Date 2003-10-08 Time 12:23 Sent To P
Notes
2003-10-08 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-08-29 Time 10:44 Rev Time 0.00
Received By sthyng Date 2003-08-29 Time 10:43 Sent To P
Notes
2003-09-02 00:00:00TO KS DESK (PERMIT PACKAGE SHOULD BE
 THERE, PUT TWO TOGETHER)
2003-08-29 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-28 Cont ID  
Sent By dbaxter Date 2003-08-28 Time 09:17 Rev Time 0.00
Received By dbaxter Date 2003-08-28 Time 09:17 Sent To P
Notes
2003-08-28 00:00:00TO KSTEVENS DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-21 Cont ID  
Sent By shernand Date 2003-07-21 Time 16:02 Rev Time 0.00
Received By shernand Date 2003-07-21 Time 16:02 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-18 Cont ID  
Sent By mmclean Date 2003-07-21 Time 11:43 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 08:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-07-28 Cont ID  
Sent By kstevens Date 2003-07-24 Time 16:28 Rev Time 0.10
Received By pkrauss Date 2003-07-28 Time 07:26 Sent To B
Notes
2003-07-28 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW FORM 600C SUBMITTED WITH BUILDING
 PERMIT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-10-18 Cont ID  
Sent By kstevens Date 2003-10-18 Time 09:18 Rev Time 0.33
Received By kstevens Date 2003-10-18 Time 09:18 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-09-06 Cont ID  
Sent By csiegber Date 2003-10-08 Time 12:23 Rev Time 0.33
Received By kstevens Date 2003-09-06 Time 19:43 Sent To B
Notes
2003-09-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA STATUTES
 FLORIDA ADMINISTRATION CODE
  
 1) COMMENTS FROM THE FIRST REVIEW HAVE
 NOT BEEN ADDRESSED. SEE ATTACHED COPY OF
 FIRST REVIEW FOR REFERENCE.
 2) ORIGINAL PERMIT APPLICATION NOT RE-
 TURNED WITH RESUBMITTAL. APPLICATION RE
 QUIRED FOR PERMIT.
 3) SEE ATTACHED SHEET CONCERNITG FLORIDA
 STATUTE 553.80(2)(B).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-24 Cont ID  
Sent By sthyng Date 2003-09-02 Time 13:18 Rev Time 0.33
Received By kstevens Date 2003-07-24 Time 16:14 Sent To M
Notes
2003-07-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA STATUTES
  
 1) SHT A-2 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN NOR DOES IT
 MEET CODE REQUIREMENTS. THE LAV IS NOT
 VENTED AND TRAP IS AN "S" TRAP.
 SEE EXAMPLE OF RISER DIAGRAM THAT RE-
 FLECT THE FLOOR PLAN AND MEETS CODE ON
 SHEET A-2.
 2) PLEASE MAKE SEPARATE SETS OF PLANS
 FOR REVIEW. LOOSE SHEETS ARE NOT ACCEPT-
 ABLE. ONE SET IS NOT SIGNED/SEALED/DATED
 3) SEE ATTACHED SHEET CONCERNING DATES,
 AND LICENSE NUMBERS FOR ENGINEERS.
 61G15-23.002(2).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-21 Cont ID  
Sent By shernand Date 2003-07-18 Time 08:08 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***