Plan Review Details - Permit 03071134
Plan Review Stops For Permit 03071134
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-12-01 Cont ID  
Sent By rmcdouga Date 2003-12-01 Time 16:35 Rev Time 1.00
Received By rmcdouga Date 2003-12-01 Time 16:35 Sent To  
Notes
2003-12-01 00:00:00REVISION TO CHANGE BATHROOM DOOR TO A
 POCKET DOOR IS OK 12-1-03

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By btrobaug Date 2003-11-24 Time 09:30 Rev Time 2.50
Received By rmcdouga Date 2003-09-16 Time 08:08 Sent To  
Notes
2003-09-16 00:00:00PROVISO
  
 1) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY FBC 1804.2.2, PRIOR TO
 POURING THE FOUNDATION.
  
 2) SUBMIT A SIGNED AND SEALED LETTER
 FROM THE STORM PANEL ENGINEER (KNEZIVICH
 AND ASSOC.) STATING THAT THE CALK-IN
 ANCHORS CAN BE USED IN HOLLOW CONCRETE
 BLOCK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-11 Time 12:37 Rev Time 2.00
Received By rmcdouga Date 2003-09-03 Time 10:45 Sent To  
Notes
2003-09-03 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) SUBMIT A SIGNED AND SEALED COPY OF
 A SOIL BORING TEST REPORT AS REQUIRED BY
 FBC 1804.2.2.
  
 3) REVISE GLASS BLOCK NOTE #5 ON A12.
 THE GLASS BLOCK IS REQUIRED TO HAVE A
 UNIFORM FACE THICKNESS OF 0.25 INCH WHEN
 LOCATED WITHIN (3) FEET HORIZONTALLY OF
 THE STANDING OR WALKING SURFACE OF A
 BATHTUB, SHOWER, ETC. SEE FBC 2405.2.1
 AND 2405.2.2.
  
 4) THE "REDLINED" CHANGE TO THE NEGATIVE
 WINDLOAD PRESSURE FOR THE DOUBLE ENTRY
 DOORS ON THE WIND LOAD SCHEDULE ON A1 IS
 REQUIRED TO BE INITIALED AND DATED BY
 THE DESIGNER OF RECORD.
  
 5)SUBMIT A SIGNED AND SEALED COPY OF THE
 LETTER FROM KENEZEVICH AND ASSOCIATES
 ADDRESSING THE USE OF CALK-IN ANCHORS IN
 CONCRETE BLOCK. THE LETTER SHOULD
 INDICATE THE PSI OF THE BLOCK AS TESTED.
  
 6) PROVIDE ADDITIONAL INFORMATION FOR
 THE INSERT HEADER AT THE COVERED LANAI.
 SPECIFY HOW IT WILL BE ANCHORED FOR
 UPLIFT, HOW THE TRUSSES WILL BE ATTACHED
 TO THE HEADER, HOW THE HEADER WILL BEAR
 ON THE WALLS AT EACH END, ETC.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-13 Cont ID  
Sent By dpalmer Date 2003-08-28 Time 07:21 Rev Time 3.00
Received By rmcdouga Date 2003-08-13 Time 15:54 Sent To  
Notes
2003-08-13 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
  
 3) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY FBC 1804.2.2.
  
 4) THE GLASS BLOCK IN THE MASTER BATH
 AND BATH 2 ARE IN HAZARDOUS LOCATIONS
 AND ARE REQUIRED TO BE TEMPERED OR HAVE
 A UNIFORM FACE THICKNESS OF 0.25" PER
 FBC 2405.2.
  
 5) THE FULL BATH ON THE FIRST FLOOR IS
 REQUIRED TO HAVE A DOOR WITH A 29" CLEAR
 OPENING PER FBC 11-4.23.2.
  
 6) FBC 1609.4 DOES NOT ALLOW THE ONE-
 THIRD INCREASE IN THE STEEL CALCULATIONS
 FOR COMBINATION LOADS. PLEASE REVISE THE
 VALUES LISTED IN THE ANCHOR SCHEDULES ON
 SHEETS A7 AND A8 TO VALUES THAT DO NOT
 INCLUDE THIS INCREASE. SEE THE 2003 USP
 CATALOG.
  
 7) THE 10'X 8' SLIDING GLASS DOOR (M) IS
 NOT LISTED IN THE WINDLOAD SCHEDULE ON
 A1.
  
 8) THE OVERHEAD GARAGE DOOR PRODUCT
 APPROVAL DOES NOT MEET THE PRESSURES
 LISTED IN THE WINDLOAD SCHEDULE ON A1.
  
 9) THE SH35 WINDOWS (W) AND (Y) WILL
 REQUIRE 3/16" TEMPERED GLASS TO MEET THE
 SPECIFIED WINDLOADS ACCORDING TO THE
 PRODUCT APPROVAL THAT WAS SUBMITTED.
  
 10) THE PRODUCT APPROVAL FOR THE DOUBLE
 ENTRY DOOR DOES NOT MEET THE WINDLOAD
 PRESSURES LISTED ON THE PLANS.
  
 11) PLEASE REVIEW THE WINDLOAD PRESSURES
 ON THE PLANS THEY MAY BE HIGHER THAN
 NEEDED FOR EXPOSURE B.
  
 12) THE KEY PLAN AND SCHEDULE FOR THE
 STORM PANELS DO NOT MATCH THE PLANS.
 PLEASE CORRECT.
  
 13) THE PRODUCT APPROVAL FOR THE STORM
 PANELS LISTS THE MINIMUM PANEL LENGTH
 FOR DIRECT MOUNT INSTALLATIONS AS 46".
 THE SCHEDULE LISTS SMALLER LENGTHS.
 PLEASE CORRECT.
  
 14) THE CALK-IN ANCHORS ARE HI-LITED ON
 THE PRODUCT APPROVAL FOR HOLLOW CONCRETE
 BLOCK. THEY CAN NOT BE USED FOR HOLLOW
 CONCRETE BLOCK WITH C1 CONNECTION TYPE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-08-30 Cont ID  
Sent By dpalmer Date 2004-08-30 Time 07:07 Rev Time 0.10
Received By dpalmer Date 2004-08-30 Time 07:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2004-08-03 Cont ID  
Sent By csiegber Date 2004-08-24 Time 10:05 Rev Time 0.33
Received By dpalmer Date 2004-08-03 Time 13:25 Sent To  
Notes
2004-08-03 00:00:00********** UNSAT *********
  
 1)NOTE: PLEASE SEE SD TO BE MOVED INTO
 MASTER BEDRM.
 NFPA-72 8-1.4.1.6.2
  
 2)NOTE: PLEASE SEE ARC FAULT PROTECTION
 IS SHOWN FROM 99 NEC.
 ALL OUTLETS IN BEDRMS, FANS, SD'S,LTS
 RECEPT . 2002 NEC 210.12
  
 3)NOTE: PLEASE SEE MISSING LICENSE #'S
 ON TITLE BLOCK. FAC 61G1-16.004, FS
 481.219
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-11-24 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:26 Rev Time 0.50
Received By btrobaug Date 2003-11-24 Time 09:30 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-28 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:25 Rev Time 0.33
Received By dpalmer Date 2003-08-28 Time 07:21 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-30 Cont ID  
Sent By csiegber Date 2003-08-27 Time 15:55 Rev Time 0.33
Received By dpalmer Date 2003-07-30 Time 19:03 Sent To M
Notes
2003-07-30 00:00:00********* NOTES REDLINED ************
  
 1)NOTE: MISSING SD LEADING TO FLOOR
 ABOVE IN VICINITY OF STAIRS. NFPA-72
 8-1.4.2
  
 2)NOTE: PLEASE SEE OCP AND AWG FOR
 GEN LT CIRCUITS, SHOWN AS 2P 60A AND
 #6 AWG.??

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 10:05 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 10:05 Sent To E
Notes
2004-08-24 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:26 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 08:26 Sent To E
Notes
2004-07-29 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:25 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 15:25 Sent To E
Notes
2003-11-21 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-09-19 Time 14:20 Rev Time 0.00
Received By csiegber Date 2003-09-19 Time 14:20 Sent To B
Notes
2003-09-19 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-11 Cont ID  
Sent By csiegber Date 2003-09-11 Time 12:37 Rev Time 0.00
Received By csiegber Date 2003-09-11 Time 12:37 Sent To B
Notes
2003-09-11 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-08-27 Time 15:55 Rev Time 0.00
Received By csiegber Date 2003-08-27 Time 15:55 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-24 Cont ID  
Sent By alange Date 2003-07-24 Time 13:23 Rev Time 0.00
Received By alange Date 2003-07-24 Time 13:23 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-18 Cont ID  
Sent By mmclean Date 2003-07-24 Time 10:59 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 09:29 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-10 Cont ID  
Sent By dpalmer Date 2003-07-30 Time 19:03 Rev Time 0.25
Received By pkrauss Date 2003-08-10 Time 18:44 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-11 Cont ID  
Sent By pkrauss Date 2003-08-10 Time 18:44 Rev Time 0.25
Received By jleech Date 2003-08-11 Time 16:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-24 Cont ID  
Sent By shernand Date 2003-07-18 Time 09:29 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***