Plan Review Details - Permit 03071113
Plan Review Stops For Permit 03071113
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-12-12 Cont ID  
Sent By rmcdouga Date 2003-12-12 Time 15:36 Rev Time 1.00
Received By rmcdouga Date 2003-12-12 Time 15:36 Sent To  
Notes
2003-12-12 00:00:00REVISION IS DENIED
  
 1) SPECIFY THE EDGE DISTANCE FOR THE
 THROUGH BOLT IN THE 4X6 POST. SPECIFY
 THE UPLIFT VALUE OF THIS CONNECTION.
  
 THIS DETAIL WAS REJECTED FOR THE SAME
 ITEMS ON 11/12/03.
 A REVISION WAS APPROVED ON 12-1-03 FOR
 THIS CONNECTION. I HAVE ATTACHED A COPY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-12-12 Cont ID  
Sent By csiegber Date 2003-12-12 Time 12:06 Rev Time 0.50
Received By rmcdouga Date   Time   Sent To  
Notes
2003-12-12 00:00:00REVISION TO CHANGE PRIVACY FENCE TO WALL

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-12-02 Cont ID  
Sent By rmcdouga Date 2003-12-02 Time 08:36 Rev Time 1.00
Received By rmcdouga Date 2003-12-02 Time 08:36 Sent To  
Notes
2003-12-02 00:00:00REVISED DETAILS ON A8 ARE OK 12-2-03.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-11-13 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:22 Rev Time 1.00
Received By rmcdouga Date 2003-11-12 Time 07:45 Sent To  
Notes
2003-11-13 00:00:00REVISION UNSAT
  
 1) SPECIFY THE EDGE DISTANCE FOR THE
 THROUGH BOLT IN THE 4X6 WOOD POST.
 SPECIFY THE UPLIFT VALUE OF THIS
 CONNECTION.
  
 2) LETTER TO DELETE THE PRIVACY WALL IS
 OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-08-13 Cont ID  
Sent By csiegber Date 2003-11-10 Time 08:34 Rev Time 3.00
Received By rmcdouga Date 2003-08-13 Time 07:39 Sent To  
Notes
2003-08-13 00:00:00BUILDINGPROVISO
  
 1) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY 1804.2.2 BEFORE POURING THE
 FOUNDATION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-07-19 Cont ID  
Sent By dpalmer Date 2004-07-19 Time 17:12 Rev Time 0.33
Received By dpalmer Date 2004-07-19 Time 17:12 Sent To  
Notes
2004-07-19 00:00:00REDLINED 2002NEC 210.12

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-30 Cont ID  
Sent By csiegber Date 2004-07-15 Time 15:39 Rev Time 0.25
Received By dpalmer Date 2003-07-30 Time 19:30 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-07-15 Cont ID  
Sent By csiegber Date 2004-07-15 Time 15:39 Rev Time 0.00
Received By csiegber Date 2004-07-15 Time 15:39 Sent To E
Notes
2004-07-15 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-12-12 Cont ID  
Sent By csiegber Date 2003-12-12 Time 12:06 Rev Time 0.00
Received By csiegber Date 2003-12-12 Time 12:06 Sent To B
Notes
2003-12-12 00:00:00TO RM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 15:22 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 15:22 Sent To B
Notes
2003-11-21 00:00:00TO RM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-10 Cont ID  
Sent By csiegber Date 2003-11-10 Time 08:34 Rev Time 0.00
Received By csiegber Date 2003-11-10 Time 08:34 Sent To B
Notes
2003-11-10 00:00:00TO RM DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-15 Cont ID  
Sent By alange Date 2003-08-15 Time 08:24 Rev Time 0.00
Received By alange Date 2003-08-15 Time 08:23 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-24 Cont ID  
Sent By alange Date 2003-07-24 Time 13:22 Rev Time 0.00
Received By alange Date 2003-07-24 Time 13:21 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-18 Cont ID  
Sent By mmclean Date 2003-07-24 Time 11:01 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 09:29 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-08-18 Cont ID  
Sent By pkrauss Date 2003-08-18 Time 08:05 Rev Time 0.25
Received By pkrauss Date 2003-08-18 Time 08:05 Sent To B
Notes
2003-08-18 00:00:00PLAN APPROVED 8-9-03 - FLOOR PLAN
 REVERSED TO BUILDING FLOOR PLAN

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-10 Cont ID  
Sent By alange Date 2003-08-15 Time 08:24 Rev Time 0.25
Received By pkrauss Date 2003-08-10 Time 18:42 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-11 Cont ID  
Sent By pkrauss Date 2003-08-10 Time 18:43 Rev Time 0.25
Received By jleech Date 2003-08-11 Time 18:18 Sent To B
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-08-18 Cont ID  
Sent By rmcdouga Date 2003-08-13 Time 10:04 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-08-13 00:00:00IMPACT FEES PAID AND NOC SUBMITTED.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-24 Cont ID  
Sent By shernand Date 2003-07-18 Time 09:29 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***