| Plan Review Stops For Permit 03071035 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-13 |
Time |
11:51 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-13 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2004-12-13 00:00:00 | REVISED A2 DATED 8/22/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-10-13 |
Time |
13:31 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-10-13 |
Time |
13:31 |
Sent To |
P |
|
| Notes |
| 2004-10-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SUBMIT A SECOND COPY OF SHEET A2. | | | ONLY ONE WAS SUBMITTED.THE OTHER SHEET | | | MARKED "B" ON THE OUTSIDE IS AN ELECTRIC | | | SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-04-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
08:22 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-04-12 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-03-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-26 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-03-26 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2004-03-26 00:00:00 | NEED SEALED ORIGINAL ELEVATION | | | CERTIFICATE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-25 |
Time |
14:00 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-03-25 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | **PROVISO**ELEVATION CERTIFICATE BEFORE | | | ISSUANCE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-22 |
Time |
16:55 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2003-12-09 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2003-12-09 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEPARATE PERMITS REQUIRED.4X FEE | | | FOR PLUMBING AND ELECTRIC. | | | | | | 2.)ADDITIONAL FEES DUE (VALUE | | | ADJUSTMENT, 4X FEE, RADON), $5211.03. | | | SEE ATTACHED.BZ231389 | | | | | | 3.)WHEN RESUBMITTING, SUBMIT ALL OLD | | | PLANS PREVIOUSLY REVIEWED. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #8. ENERGY | | | CALCS REQUIRED FBC13-103.1.2.MANUAL | | | J ONLY SUBMITTED. | | | | | | 5.)SOILS REPORT IS FOR THE POOL. | | | SUBMIT TWO SEALED COPIES OF A SOILS | | | REPORT FOR THE ADDITION. | | | | | | 6.)BOTTOM CORD LIVE LOAD FOR THE | | | TRUSSES SHOULD BE 10 FOR ATTICS WITHOUT | | | STORAGE, 30 FOR ATTICS WITH STORAGE, | | | FBC TABLE 1604.1. | | | | | | 7.)PREVIOUS COMMENT #19 IN REGARDS TO | | | THE FLOOD ZONE WA ADDRESSED BY AN | | | ELEVATION CERTIFICATE SHOWING EXISTING | | | TOP OF BOTTOM FLOOR AT 10'.SUBMIT | | | A SEALED ELEVATION CERTIFICATE (COPY | | | ONLY SUBMITTED). | | | | | | 8.)IF THE HURRICANE SHUTTER | | | INSTALLATION SCHEDULE IS NOT SUBMITTED, | | | A SEPARATE PERMIT WILL BE REQUIRED FOR | | | SHUTTERS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-03 |
Time |
12:33 |
Rev Time |
4.00 |
| Received By |
sthyng |
Date |
2003-08-07 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | ******CORRECTIONS****** | | | | | | 1.)THERE ARE HOLDS ON THIS PROPERTY, | | | SEE ATTACHED. | | | | | | 2.)THE POOL IS TO BE PERMITTED | | | SEPARATELY.REMOVE FROM THE PERMIT | | | APPLICATION. | | | | | | 3.)SEPARATE PERMITS REQUIRED. | | | | | | 4.)THE SITE PLAN SHOWS "ONE STORY | | | RESIDENCE"; SHOULD SHOW EXISTING AND | | | PROPOSED. | | | | | | 5.)IS THE PRIVACY WALL A PART OF THIS | | | PERMIT?IF IT IS, IINDICATE AS PROPOSED | | | AND INCLUDE ON THE FOUNDATION PLAN.THE | | | FOOTER CANNOT ENCROACH THE PROPERTY | | | LINE.INCLUDE A DETAIL FOR THE WALL. | | | IS THE NEW CONCRETE DRIVE A PART OF THIS | | | PERMIT?INCLUDE ON THE APPLICATION. | | | | | | 6.) PROVIDE AREA CALCULATIONS ON THE | | | PLAN; INCLUDE EXISTING AND PROPOSED. | | | ADDITIONS OVER 25% MUST COMPLY WITH | | | FBC3401.7.1.2.1 AS AMENDED 7/1/03. | | | | | | 7.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED, AND THE ORIGINAL RECEIPT | | | ATTACHED TO THE APPLICATION.233-5025 | | | | | | 8.)ENERGY CALCS REQUIRED FBC13-103.1.2 | | | SIGN THE OWNER/AGENT LINE AS WELL AS | | | THE PREPARER LINE OF THE ENERGY CALC. | | | | | | 9.)ADDITIONAL FEES ARE REQUIRED DUE | | | TO VALUE ADJUSTMENT.ADDITIONAL FEES | | | MAY BE ADDED AFTER THE SCOPE OF WORK | | | IS DETERMINED.ADJUSTMENT WAS MADE FOR | | | THE ADDITION ONLY; NO INTERIOR | | | RENOVATIONS, DRIVEWAY, OR ENTRY WALL | | | AND GATES.PROVIDE AN ESTIMATED VALUE | | | FOR THESE ITEMS, PROVIDING CONTRACTS IF | | | AVAILABLE. | | | | | | 10.) WILL THE EXISTING FOOTER AND TIE | | | BEAM TIE INTO THE EXISTING?IF NOT, | | | NOTE ON THE PLAN. | | | | | | 11.) SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR THE FOLLOWING: | | | ROOF TILE (MAY BE SUBMITTED WITH THE | | | ROOF PERMIT APPLICATION) | | | SINGLE HUNG WINDOW | | | IMPACT PROTECTION FBC1606.1.4 | | | FRENCH DOORS | | | | | | 12.) IF THE ROOF TILE IS FOAM SET (1-A1) | | | PROVIDE PRODUCT APPROVALS FOR THE | | | POLY FOAM. | | | | | | 13.) CRAWL SPACE SHALL HAVE CROSS | | | VENTILATION; SIZE TO CONFORM TO FBC | | | 1804.6.3. | | | | | | 14.) WOOD FLOOR JOISTS TO BE OF | | | NATURALLY DURABLE WOOD OR PRESSURE | | | TREATED, FBC2304.3.4. | | | | | | 15.) CHANGES DRAWN ON THE PLAN BY THE | | | DESIGNER SHOULD BE INITIALED AND DATED. | | | | | | 16.) SPECIFY A GIRDER CONNECTION ON | | | THE ROOF FRAMING PLAN. | | | | | | 17.) TRUSS ENGINEERING IS FOR 110 MPH | | | WIND, SBCCI 97.THIS IS AN INCORRECT | | | WIND AND CODE DESIGNATION, FBC FIGURE | | | 1606. | | | | | | 18.) PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 19.) THIS PROPERTY IS IN A FLOOD ZONE. | | | THE LOWEST FLOOR IS TO BE ELEVATED TO | | | A MINIMUM OF 6" ABOVE THE BASE FLOOD | | | ELEVATION; INDICATE ON THE PLAN, CITY | | | OF WEST PALM BEACH MUNICIPAL CODE. | | | | | | 20.) SUBMIT A HURRICANE SHUTTER | | | ATTACHMENT SCHEDULE, SEE ATTACHED. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-08 |
Time |
14:20 |
Rev Time |
0.60 |
| Received By |
dpalmer |
Date |
2005-10-08 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2005-10-08 00:00:00 | ********* UNSAT *********** | | | | | | PLEASE SEE THERE ARE ITEMS NOT CORRECT | | | FROM REDLINED PLANS IN SEPT 04. | | | | | | 1)NOTE: PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR TO BE SIZED PER | | | 250.66 1/0 MIN. | | | | | | 2)NOTE: PLEASE SEE ARC FAULT PROTECTION | | | IS STILL BEING SHOWN FOR RECEPTS ONLY. | | | 210.12 2002 PLANS SUBMITTED FOR PERMIT | | | AFTER JULY 1ST, 2003 WHEN CODE CHANGED | | | TO 2002 NEC. | | | | | | 3)NOTE: PLEASE SEE MISSING SD'S REQUIRED | | | IN EXISTING DWELLING INSIDE AND OUTSIDE | | | ALL SLEEPING RMS. NFAP-72 8-1.4.2 | | | CHAPTER 34 FBC. | | | | | | 4)NOTE: PLEASE SEE WHAT APPEARS TO BE A | | | BATHRM IN NEW ADDTION IS REQUIRED TO | | | INDICATE GFI RECEPT. 210.8 | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 | | | | | | 6)NOTE: PLEASE SEE MISSING GFI RECEPTS | | | REQUIRED ALONG KTICHEN COUNTERSPACE. | | | 210.52C1,210.8A6 | | | | | | 7)NOTE: PLEASE CORRELATE AND COMPLETE | | | RISER DIAGRAM FOR CODE COMPLIANCE. | | | PLEASE SHOW ALL CONDUCTORS. | | | PLEASE SEE ONLY ONE 2/0 FOR 200A PANEL. | | | PLEASE SEE CONDUCTOS FOR PANEL "C" ARE | | | SHOWN AS 3/0'S FOR 100A OCP AND IN 1 1/4 | | | PIPE. PLEASE SEE MIN SIZE REQUIRED FOR | | | CONDUCTORS TO BE CALCULATED FROMNEC | | | TABLES. | | | PLEASE SEE FEEDERS INDICATE ON PANEL "B" | | | TO FEED PANEL "C" DO NOT MEET CODE | | | COMPLIANCE. 240.4,310.16 | | | | | | 8)NOTE: PLEASE SEE"HOT TUB" IS BEING | | | SHOWN ON PANEL SCHEDULE, HOWEVER PLANS | | | DO NOT SHOW THIS?? | | | PLEASEALSO SEE PANEL SCHEDULE SHOWS | | | 300A OCP?? ON #6?? | | | 215.5,240.4,310.16 ETC. | | | | | | 9)NOTE: PLEASE SHOW ALL EXISTING | | | DWELLING ELECTRICAL AS EITHER EXISTING | | | MEETING 2002 NEC OR NEW TO BE BROUGHT UP | | | TO CODE. | | | FBC CHAPTER 34 ADDITIONS AND REMODELING | | | EXISTING. | | | THIS WAS REDLINED ON PLANS FROM SEPT 04. | | | PLEASE SEE PLANS REFERENCE 2001?? | | | 2002 NEC IS CODE IN EFFECT. | | | | | | 10)NOTE: PLEASE LIST THE REQUIRED | | | DEDICATED CIRCUIT(S) FOR BATH(S). | | | 210.52D,210.11C3, MUST BE 20A AND #12. | | | | | | 11)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS PER 250.110,250.122 | | | 250.24 ETC. | | | | | | 12)NOTE: PLEASE INCLUDE NEW OR EXISTING | | | SEC'S WHICH MEETS THE 350A SERVICE | | | SHOWN. | | | PLEASE INLCUDE SIZE OF RISER. | | | 310.15B6,310.16, 240.4, 215.5 ETC. | | | | | | 13)NOTE: PLEASE SEE SWITCHES NOT SHOWN | | | AS 3-WAYS, WHEN WIRING ON PLANS SHOULD | | | INDICATE THIS. | | | | | | 14)NOTE: PLEASE SEE NUMEROUS BRKRS ON | | | PANEL SCHEDULES WHICH DO NOT SEEM TO | | | CORRELATE WITH AWG SHOWN. | | | 30A OCP, #6, 15A, #12 | | | | | | 15)NOTE: PLEASE SEE MISSING FRONT GFI | | | 210.52E | | | | | | 16)NOTE: PLEASE SEE MISSING EGRESS LT?? | | | FRONT DOOR. 210.70 | | | PLEASE SEE GFI REQUIRED IN GARAGE. | | | 210.52G, 210.8 | | | | | | 17)NOTE: PLEASE SEE A GFI CIRCUIT IS | | | BEING SHOWN AS "OPT" ON PANEL SCHEDULE?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-24 |
Time |
06:44 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-09-24 |
Time |
06:34 |
Sent To |
M |
|
| Notes |
| 2004-09-24 00:00:00 | *** NOTES FROM FIRST TWO REVIEWS** | | | | | | PLEASE SEE RISER HAS NOW BEEN REVISED. | | | | | | SIZE OF GROUNDING ELECTRODE CONDUCTOR | | | TO BE PER 250.66.#2 | | | | | | EXISITNG TO MEET 2002 NEC AS REQUIRED | | | PER FBC CHAPTER 34 3407.7.1 | | | | | | SD'S PER NFPA-72 8-1.4.1.6.2 | | | GFI'S |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-20 |
Time |
13:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-22 |
Time |
07:53 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-15 |
Time |
11:30 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-11-07 |
Time |
13:01 |
Sent To |
P |
|
| Notes |
| 2003-11-07 00:00:00 | ************ UNSAT ************** | | | | | | PLEASE SEE THAT SOME NOTES FROM FIRST | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: PLEASE SEE 2002 NEC, ARC FAULT | | | PROTECTION IS NO LONGER JUST FOR RECEPTS | | | PLEASE SEE 210.12. PLEASE LIST ON PANEL | | | | | | SCHEDULE. | | | 2)NOTE: PLEASE SEE RECEPT NEXT TO BAR | | | SINK, GFI PER 210.8 | | | | | | 3)NOTE: PLEASE SHOW SERVICE ON PLANS, | | | PLANS SHOW ONE PANEL IN GARAGE ONLY? | | | PLEASE SEE RISER DIAGRAM. | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE RISER SHOWS NEW | | | PANEL BUT NOTHING ON HOW THIS PANEL IS | | | BEING FED? CONDUCTORS, CONDUIT ETC ETC. | | | PLANS SHOWS 150 A SERVICE AND 200A MAINS | | | W/ 200A LOAD ETC? PLEASE CORRELATE | | | PLANS AND RISER TO NEC. 230.42, 240, | | | 310.15B6ETC. 215.5 | | | | | | 5)NOTE: PLEASE SEE AHU#2, SHOWS 10KW AND | | | 4.5 KW ETC. PLEASE CORRELATE. | | | | | | 6)NOTE: PLEASE SEE PLANS REF 2001 NEC, | | | WE ARE UNDER THE 2002 NEC. | | | | | | 7)NOTE: PLEASE SEEOTHER OCP/BRKR | | | SIZES ON PANEL SCHEDULE. | | | PLEASE CORRELATE OCP/KW/ AWG. | | | AHU'S PUMP' ETC. | | | | | | 8)NOTE: PLEASE SEE ATTACHED COPY OF | | | FS,553.80.(2)(B). | | | | | | PLEASE REMOVE OLD SHEETS AND INSERT NEW | | | SHEETS INTO COMPLETE STES FOR REVIEW AND | | | STAMPING. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
15:27 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-07-24 |
Time |
09:07 |
Sent To |
P |
|
| Notes |
| 2003-07-24 00:00:00 | ****************UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE ATTACHED COPY OF THE | | | FAC 61G1-16.004 FOR REQ'D INFORMATION | | | IN TITLE BLOCK. | | | | | | 2)NOTE: PLEASE SEE 2001 FBC CHAPTER 34 | | | 3401.7.1 PLEASE SHOW ALL EXSITINGS ROOMS | | | BEING UPGRADED TO TODAYS NEC STANDARDS. | | | RECEPTS, SWITCHES,LTS , WIRING ETC ETC. | | | | | | 3)NOTE: PLEASE SUBMIT THE AIC RATING | | | FOR NEW SERVICE EQUIPMENT. | | | | | | 4)NOTE: PLEASE CLARIFY HOW MANY A/C | | | SYSTEMS THERE ARE? SHOWS A AHU IN NEW | | | ADDTION, BUT NOTHING SHOWN FOR DISC? | | | 440.11 AND LOAD CALCS?220 | | | | | | 5)NOTE: PLANS MENTION BEDROOM RECEPTS TO | | | BE ARC FAULT TYPE. PLEASE LIST ALL THE | | | REQ'D ARC FAULT PROTECTED CIRCUIT ON | | | PANEL SCHEDULE INCLUDING ALL EXISTING | | | BEDRROMS. 210.12 | | | AN ARC FAULT RECEPT IS NOT AVAILABLE | | | AT THIS TIME. | | | | | | 6)NOTE: PLEASE SHOW RECEPT NEXT TO BAR | | | SINK AS GFI ALSO. 210.8 | | | | | | 7)NOTE: PLEASE SHOW SERVICE LOCATION | | | /PANEL/ METER ON PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-05 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-05 |
Time |
15:27 |
Sent To |
E |
|
| Notes |
| 2005-10-05 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-02 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-02 |
Time |
12:47 |
Sent To |
M |
|
| Notes |
| 2004-11-02 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-20 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-20 |
Time |
13:50 |
Sent To |
E |
|
| Notes |
| 2004-09-20 00:00:00 | TO COMM BD# | | | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-15 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-03-15 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
| 2004-03-15 00:00:00 | REMOVED FROM BOARD, TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-02 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-02 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | TO COMM BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
15:27 |
Sent To |
E |
|
| Notes |
| 2003-11-06 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-21 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-21 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-21 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-15 |
Time |
14:08 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-22 |
Time |
17:43 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-11-22 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
07:53 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
07:42 |
Sent To |
B |
|
| Notes |
| 2004-10-07 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE DUCT SIZE FOR ALL | | | NEW DUCTWORK INDICATED ON THE PLAN. | | | | | | 2.PLANS WERE SUBMITTED WITH A TITLE | | | BLOCK AND SHALL BE SIGNED SEALED AND | | | DATED BY THE ARCHITECT PER FS 481.221 | | | & FAC 61G1-16.001 THROUGH .004. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-24 |
Time |
06:44 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-12-03 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2003-12-03 00:00:00 | PROVISO: | | | PER 2001 FBC(M) 601.4 - PLEASE SEE | | | ATTACHED FOR PROPER SIZING OF THE RETURN | | | AIR JUMPERS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-20 |
Time |
07:51 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2003-07-25 |
Time |
15:23 |
Sent To |
B |
|
| Notes |
| 2003-07-25 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE ENERGY AND | | | MANUAL J CALCULATIONS WITH PERMIT | | | APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-14 |
Time |
07:53 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-14 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2004-10-14 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FAC 61G1-16.003/FS481.2055 THE PERSONAL | | | SEAL, SIGNATURE AND DATE OF THE ARCHIT- | | | ECT SHALL APPEAR ON ALL ARCHITECTURAL | | | DOCUMENTS TO BE FILED FOR PUBLIC RECORD. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-10-13 |
Time |
13:31 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-03-22 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-22 |
Time |
10:50 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-11-20 |
Time |
07:51 |
Sent To |
M |
|
| Notes |
| 2003-11-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: SANITARY RISER | | | DIAGRAM DOES NOT REFLECT THE FLOOR PLAN, | | | NOR DOES IT MEET CODE REQUIREMENTS. | | | THE BAR SINK IS NOT SHOWN ON THE SANT. | | | RISER DIAGRAM. THE WASH MACHINE AND BAR | | | SINK SHALL CONNECT DOWNSTREAM OF THE | | | BATHROOM FIXTURES. 909.1. THE SHOWER AND | | | BIDET ARE NOT VENTED. 901.2.1. THE BIDET | | | REQUIRES A TRAP, 1002.1 | | | SEE ORIGINAL PLAN FOR RED LINE CORRECT- | | | IONS GIVEN TO ASSIST IN SUBMITTING A | | | SANT. RISER THAT REFLECTS FLOOR PLAN AND | | | MEETS CODE REQUIREMENTS. | | | 2) SEE ATTACHED SHEET CONCERNING FLORIDA | | | STATUTE 533.80(2)(B) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-07 |
Time |
13:41 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-07-24 |
Time |
15:53 |
Sent To |
M |
|
| Notes |
| 2003-07-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA STATUTES | | | | | | 1) ONLY THE FIXTURES WITH-IN THE BATH- | | | ROOM GROUP SHALL CONNECT TO THE WET- | | | VENTED HORIZONTAL BRANCH DRAIN. ANY | | | ADDITIONAL FIXTURES (BAR SINK/WASH MACH- | | | INE) SHALL DISCHARGE DOWNSTREAM OF THE | | | WET VENT. SECTION 909.1 (SEE RED LINE | | | CORRECTIONS ON RISER DIAGRAM). | | | | | | 2) SEE ATTACHED SHEET CONCERNING SEALS | | | AND PLANS. 61G1-16 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
14:08 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|