| 2003-07-16 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03070811 |
| | ADD: 400 N. FLAGLER# 2206 |
| | CONT: CASTLE FLORIDA BUILDING |
| | TEL: (561)662-7426 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | ACTION: DENIED |
| | |
| | 1) FL.S.S. 481.221.1(B) EACH REGISTERED |
| | INTERIOR DESIGNER SHALL OBTAIN A SEAL AS |
| | PRESCRIBED BY THE BOARD, AND ALL DRAW- |
| | INGS, PLANS,SPECIFICATIONS, OR REPORTS |
| | PREPARED OR ISSUED BY THE REGISTERED |
| | INTERIOR DESIGNER AND BEING FILED FOR |
| | PUBLIC RECORD SHALL BEAR THE SIGNATURE |
| | AND THE SEAL OF THE REGISTERED INTERIOR |
| | DESIGNER WHO PREPARED OR APPROVED THE |
| | DOCUMENT AND THE DATE ON WHICH THEY WERE |
| | SEALED. THE SIGNATURE, DATE AND SEAL |
| | SHALL BE EVIDENCE OF THE AUTHORITY OF |
| | THAT TO WHICH THEY ARE AFFIXED. |
| | |
| | 2)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | THE PLAN DOES NOT GIVE A COMPLETE LAY- |
| | OUT OF THE UNIT, HARD TO VISULIZE THE |
| | COMPLETE SUITE. |
| | |
| | 3) DOORS 11& 25 INDICATE NEW DOORS, |
| | NO RATING IS GIVEN FOR THESE DOORS. |
| | |
| | 4)R-3 EGRESS DOOR/ 32" CLEAR: |
| | 1003.2.1. THE WIDTH OF THE MEANS OF |
| | EGRESS SHALL BE DETERMINED FROM THE |
| | OCCUPANTS SERVED IN ACCORDANCE WITH |
| | TABLE 1004.R-3 MINIMUM CLEAR OPENING OF |
| | EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS |
| | USED IN THE EXIT ACCESS SHALL PROVIDE A |
| | CLEAR OPENING OF NOT LESS THAN 32" WIDE. |
| | 1012.1.7 REQUIRED EXIT DOORS SHALL BE |
| | OPENABLE FROM THE INSIDE WITHOUT THE USE |
| | OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR |
| | EFFORT. MANUALLY OPERATED FLUSH BOLTS OR |
| | SURFACE BOLTS ARE PROHIBITED. ALL HARD- |
| | WARE MUST BE DIRECT ACTING REQUIRING NO |
| | MORE THAN ONE OPERATION. NO DIMENSION |
| | ON WIDTH OF NEW DOOR. |
| | |
| | 5) TABLE 803.3 MINIMUM INTERIOR FINISH |
| | CLASSIFICATION; PROVIDE INFORMATION |
| | BASED ON INTERIOR FINISH REQUIREMENTS |
| | BASED ON OCCUPANCY. |
| | FLAME SPREAD/ SMOKE DEVELOPMENT. |
| | |
| | 6)905.2.1 RESIDENTIAL SMOKE ALARMS: |
| | NFPA 72.A-8-1.2.1 IN FAMILY UNITS WITH |
| | MORE THAN ONE BEDROOM AREA OR WITH BED- |
| | ROOMS ON MORE THAN ONE FLOOR, MORE THAN |
| | ONE SMOKE DETECTOR IS REQUIRED. |
| | |
| | 7) TYPE II BUILDING, IF ANY DOOR BUCKS |
| | ARE REPLACED OR IF WOOD BACKING IS IN- |
| | STALLED IN WALLS, FIRE RETARDANT TREATED |
| | WOOD IS TO BE USED. |
| | |
| | 8) IN BUILDING OF TYPEI ORII CONSTRUC- |
| | TION FLOOR FINISH IF OF COMBUSTIBLE MATE |
| | RIAL, SHALL BE APPLIED DIRECTLY UPON THE |
| | FLOOR CONSTRUCTION. IF WOOD SLEEPERS ARE |
| | USED SEE CODE SECTION.803.7.1 |
| | |
| | 9) 803.7.2 COMBUSTIBLE INSULATING BOARDS |
| | MAY BE USED FOR SOUND DEADENING OR INSUL |
| | ATING OF FLOORS, EXCEPT THAT IN BUILD- |
| | INGS REQUIRED TO BE TYPE I OR II |
| | CONSTUCTION, SUCH INSULATING BOARDS |
| | SHALL NOT BE MORE THAN 1/2" THICK AND CE |
| | MENTED DIRECTLY TO THE FLOOR SLAB. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |