| Plan Review Stops For Permit 03070793 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-02-18 |
Time |
14:24 |
Rev Time |
0.50 |
| Received By |
rmcdouga |
Date |
2004-02-18 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2004-02-18 00:00:00 | SUBMITTED REVISED COVENANTS FOR EGRESS | | | EASEMENT AT ZERO LOT LINE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-18 |
Time |
10:18 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
2003-11-06 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2003-11-06 00:00:00 | | | | | | | 1) PRODUCT APPROVAL FOR IMPACT WINDOW IS | | | OK. | | | | | | 2) THE COVENANTS THAT WERE SUBMITTED DO | | | NOT MENTION AN EGRESS EASEMENT AND ARE | | | NOT ACCEPTABLE. THE ORIGINAL COVENANTS | | | NEED TO BE AMENDED TO SPECIFY AN EGRESS | | | EASEMENT FOR EMERGENCY ESCAPE AND RESCUE | | | SEE THE ATTACHED FOR REQUIREMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
15:13 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-10-09 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2003-10-09 00:00:00 | PROVISO | | | | | | 1) SUBMIT PRODUCT APPROVAL FOR THE | | | SINGLE HUNG IMPACT WINDOW FOR EGRESS IN | | | THE DEN. | | | | | | 2) 1001.1.3/ 1005.4 ZERO LOT LINE | | | EGRESS:WHEN ACCESS TO OR FROM A RE- | | | QUIRED EMERGENCY ESCAPE AND RESCUE OPEN- | | | ING OF A STRUCTURE TO THE PUBLIC WAY, | | | REQUIRES TRANSVERSING A PROPERTY | | | (ADJOINING LOT) THAT IS NOT PART OF THE | | | ONE WHICH THE STRUCTURE IS LOCATED, AN | | | EGRESS EASEMENT THROUGH THE ADJOINING | | | PROPERTY IS REQUIRED AND SHALL BE RECORD | | | ED IN THE COUNTY RECORDS. THIS EASEMENT | | | SHALL BE A MINIMUM OF 3' WIDE AND NOTH- | | | ING SHALL BE PLACED WITHIN THE EASEMENT | | | AREA WHICH WOULD BLOCK ACCESS TO THE | | | EASEMENT AND OR IMPEDE EMERGENCY EGRESS | | | FROM THE RESCUE OPENING TO THE PUBLIC | | | WAY. NO LANDSCAPING, FENCES OR OTHER | | | IMPEDIMENTS SHALL BE INSTALLED IN THIS | | | EASEMENT. THE DECLARATION OF COVENANTS | | | THAT WERE SUBMITTED DO NOT SPECIFICALLY | | | ADDRESS THE REQUIRED EGRESS EASEMENT AT | | | THE ZERO LOT LINE. SUBMIT A RECORDED | | | COPY OF REVISED COVENANTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-08 |
Time |
09:10 |
Rev Time |
2.50 |
| Received By |
rmcdouga |
Date |
2003-08-07 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | DENIED | | | | | | 1) SAME COMMENTS AS PERMIT # 03070787. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-27 |
Time |
08:39 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
08:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
08:51 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-10-07 |
Time |
13:59 |
Sent To |
P |
|
| Notes |
| 2003-10-07 00:00:00 | **************** USNAT ************** | | | | | | 1)NOTE: PLEASE SEE THAT NEW ELECTRICAL | | | RISER DIAGRAM IS NOW SUBMITTED. | | | PLEASE SEE MISSING REQ'D FOOTER STEEL | | | AND COLD WATER PER 250.50. | | | | | | 2)NOTE: PLEASE CORRELATE LOADS/RISER/AND | | | PANEL SCHEDULES. NO PANEL SCHEDULE/LOADS | | | SHOWN FOR A/C SUB PANEL? | | | | | | 3)NOTE: PLANS SHOW 2 A/C SYSTEMS AND YET | | | MAIN PANEL SCHEDUL ONY SHOWS ONE FEED | | | FOR AHU AND LOAD CALCS ONLY SHOW ONE | | | ALSO. PLEASE CORRELATE? | | | | | | 4)NOTE: PLEASE SEE MIN LOAD FOR DRYER | | | TO BE 5KW 220.18 | | | | | | 5)NOTE: PLEASE SEE 210.12. THE 2002 NEC | | | WENT INTO EFFECT 7/1/2003, AT THAT TIME | | | ARC FAULT PROTECTION IS REQ'D FOR MORE | | | THAN RECEPTS AS NOTED ON PLAN. | | | | | | PLEASE SEE COPY OFFS 553.80(2)(B),WITH | | | RESPECT TO DESIGNPROFESSIONAL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE AREA ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
09:20 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-07-25 |
Time |
07:01 |
Sent To |
M |
|
| Notes |
| 2003-07-25 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANEL SCHEDULE. 200A PANEL SHOWS | | | POOL PANEL, NOT SHOWN ON RISER. | | | | | | 2)NOTE: PLEASE SEE OCP/BRKR AND SIZING | | | FOR DRYER. PLEASE ALSO SEE WIRE SIZE. | | | | | | PLEASE NOTE, ALL OPTIONS AND PLANS WILL | | | NEED TO BE REVISED BEFORE ROUGH TO | | | WHEATHER THEY WERE INSTALLED OR NOT. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCIAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATING FOR | | | MCB SINCE THE FUSED DISC HAS BEEN | | | DELETED FROM RISER. NOTES STILL MENTION | | | FUSES TO BE USED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-18 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2004-02-18 00:00:00 | TO RM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-04 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2003-11-04 00:00:00 | TO RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
08:50 |
Sent To |
E |
|
| Notes |
| 2003-10-24 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-06 |
Time |
09:20 |
Sent To |
E |
|
| Notes |
| 2003-10-06 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-15 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-11 |
Time |
12:03 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-25 |
Time |
07:19 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-07-29 |
Time |
11:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-08 |
Time |
09:10 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-08 |
Time |
09:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-07 |
Time |
14:01 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-08-04 |
Time |
14:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-11 |
Time |
12:03 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|