| Plan Review Stops For Permit 03070764 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-15 |
Time |
07:13 |
Rev Time |
1.50 |
| Received By |
lhatten |
Date |
2003-07-22 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2003-07-25 00:00:00 | REVIEWED & STAMPED PLANS 07/22/2003 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-11 |
Time |
09:40 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-08-11 |
Time |
08:39 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-07 |
Time |
10:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-07-11 |
Time |
12:35 |
Sent To |
P |
|
| Notes |
| 2003-07-11 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE ADDRESS THE FOLLOWING COMMENTS | | | AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE NOTE THAT ALL PLANS | | | THAT ARE SIGNED AND SEALED BY ARCH/ OR | | | ENGINEER ARE REQ`D PER 61G15-23.002 FOR | | | ENGINEER AND 61G1-16.004 FOR ARCH. | | | SHALL HAVE A TITLE BLOCK.ALSO THE SEAL | | | AND SIGNATURE MAY NOT BE COPIES. | | | | | | 2} PLEASE ADD SMOKE DETECTORS TO COMPLY | | | WITH 8-4.1.6 NFPA-72. | | | | | | 3} PLEASE PROVIDE A PANEL SCHEDULE. | | | | | | 4} PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 5} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE PER 212-12. | | | | | | 6} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 7} THE GROUNDING ELECTRODE FOR A 200 | | | AMP SERVICE IS A #4 PER 250-66,PLEASE | | | INDICATE THE RATING OF THE SERVICE | | | EQUIPMENT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-07 |
Time |
10:32 |
Sent To |
E |
|
| Notes |
| 2003-08-07 00:00:00 | TO BT DESK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-12 |
Time |
15:35 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-07-15 |
Time |
07:02 |
Sent To |
B |
|
| Notes |
| 2003-07-15 00:00:00 | PROVISO: | | | | | | 1.RETURN OR TRANSFER AIR REQUIRED FROM | | | BEDROOM AREAS AS PER 2001 FBC(M) 601.4. | | | | | | 2.BATHROOM WINDOWS SHALL HAVE NO LESS | | | THAN 3 SQ FT OF OPEN SPACE OR MECHANICAL | | | VENTILATION IS REQUIRED.2001 FBC(M) | | | 402.3.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-19 |
Time |
13:24 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-08-19 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2003-08-19 00:00:00 | PASSED/PROVISO | | | | | | CONTRACTORS COPIES DO NOT HAVE AN | | | ORIGINAL SIGNATURES FOR SEAL. CONTRACTOR | | | TO BRING BACK 8-27-3. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-15 |
Time |
09:56 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-08-15 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2003-08-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA STATUTES | | | | | | 1) SEALED PLANS COPY ARE NOT ORIGINAL | | | SIGNATURES. THEY ARE COPIES OF ORIGINAL. | | | 61G15-23.002(1) | | | 2) SUBMIT 2 SETS OF PLANS. REMOVE OLD | | | SHEETS AND INSERT NEW SHEETS. 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-11 |
Time |
09:40 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-07-12 |
Time |
15:16 |
Sent To |
M |
|
| Notes |
| 2003-07-12 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES | | | | | | SEAL AND SIGNATURE ARE COPIES ON ONE SET | | | OF PLANS SUBMITTED. - SIGN AND SEAL ALL | | | SETS OF PLANS | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND ENG. NUMBER ON EACH | | | SHEET. (TITLE BLOCK) 61G15-23.002(2) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-10 |
Time |
15:31 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|