Plan Review Details - Permit 03070731
Plan Review Stops For Permit 03070731
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-01-06 Cont ID  
Sent By jwitmer Date 2004-01-06 Time 09:48 Rev Time 1.25
Received By jwitmer Date 2004-01-06 Time 09:48 Sent To PC
Notes
2004-01-06 00:00:00BUILDING REVISION # 4

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-10-10 Cont ID  
Sent By jwitmer Date 2003-10-10 Time 12:01 Rev Time 1.55
Received By jwitmer Date 2003-10-10 Time 12:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-08-28 Cont ID  
Sent By csiegber Date 2003-09-29 Time 10:00 Rev Time 0.75
Received By jwitmer Date 2003-08-28 Time 08:22 Sent To  
Notes
2003-08-28 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03070731
 ADD: 1325 N CONGRESS AVE
 CONT: INNOVATIVE CONTRACTORS
 TEL: (954)781-4167
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
 ACTION: DENIED
  
 1) COMMENT# 3 FROM 1ST REVIEW:
 SHEET A-9 INDICATES THE USE OFA FOAM
 SOFFIT, FL BLDG CODE 803.4 FOAM PLASTIC
 SHALL NOT BE USED AS AN INTERIOR TRIM.
 YOUR RESPONCE BACK, THAT IT MEETS THE
 EXCEPTION CRITERIA.
  
 THE EXCEPTION CRITERIA THAT YOU NOTE
 MUST MEET ALL OF THE (4) EXCEPTIONS.
 THE FIRST BEING 20 LBS/CU FT. THEPRO-
 DUCT TESTING REPORT SUBMITTED INDICATES
 THE DENSITY OF 1.25 LBS/PCF.
  
 THE 2ND IS MAXIMUM THICKNESS OF 1/2"
 TRIM, MAXIMUM WIDTH OF 4".
 THE DETAIL INDICATES THE WIDTH OF 4".
  
 THE TRIM MEETS THE THIRD REQUIREMENT OF
 10% OF THEWALL OR CEILING AREA.
  
 THE FLAMESPREAD RATING OF 75 NOT TO BE
 EXCEEDED. IT APPEARS TO MEET THIS
 REQUIREMENT.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-08 Cont ID  
Sent By jwitmer Date 2003-08-08 Time 14:51 Rev Time 2.25
Received By jwitmer Date 2003-08-08 Time 14:51 Sent To  
Notes
2003-08-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03070731
 ADD: 1325 N CONGRESS AVE
 CONT: INNOVATIVE CONTRACTORS INC
 TEL: (954)781-4167
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 IS THIS SPACE FIRE SPRINKLERED?
  
 2) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY. SEE TABLE 803.3.
  
 3) SHEET A-9 INDICATES THE USE OF FOAM
 SOFFIT, FL BLDG CODE 803.4, FOAM
 PLASTICS SHALL NOT BE USED AS AN INTER-
 IOR FINISH.
  
 4) SHEET A-5.1 THE HALLWAY DOOR LEADING
 TO THE RESTROOMS, MAY NOT HAVE 18" CLEAR
 ON THE LATCH SIDE, CLEAR FLOOR SPACE,
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARENCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARENCES SHALL BE
 CLEAR & LEVEL.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-17 Cont ID  
Sent By dpalmer Date 2003-12-17 Time 15:31 Rev Time 0.50
Received By dpalmer Date 2003-12-17 Time 13:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-27 Cont ID  
Sent By dpalmer Date 2003-08-27 Time 06:42 Rev Time 0.50
Received By dpalmer Date 2003-08-27 Time 06:42 Sent To  
Notes
2003-08-27 00:00:00NOTE ***
  
 ENGINEER ONLY PLACE LICENSE # ON REVISED
 SHEET.
 WROTE # HAND WRITTEN ON OTHER E-SHEETS
 ONLY.
 PLEASE NOTE THIS IS REQ'D ON ALL SHEETS
 INCLUDINGBLDG, MECH, PLUMB, UNDER
 FS471,481 AND FAC 61G15-23.002/61G1-16.
 004.
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-07-21 Cont ID  
Sent By dpalmer Date 2003-07-21 Time 11:57 Rev Time 0.50
Received By dpalmer Date 2003-07-21 Time 11:57 Sent To  
Notes
2003-07-21 00:00:00************* UNSAT **************
  
 1)NOTE: PLEASE SEE THE ATTACHED COPY OF
 FAC; 61G15-23.002 FOR REQ'D MISSING
 INFORMATION ON TITLE BLOCK FOR ENGINEER
 OF RECORD. FS 471
  
 2)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS
 AT 125%.215-3,230-42 ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2004-01-02 Cont ID  
Sent By mcarsill Date 2004-01-02 Time 14:49 Rev Time 0.00
Received By mcarsill Date 2004-01-02 Time 14:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-10-02 Cont ID  
Sent By mcarsill Date 2003-10-02 Time 07:17 Rev Time 0.00
Received By mcarsill Date 2003-10-02 Time 07:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-09-02 Cont ID  
Sent By mcarsill Date 2003-09-02 Time 16:31 Rev Time 0.00
Received By mcarsill Date 2003-09-02 Time 16:31 Sent To  
Notes
2003-09-02 00:00:001) THIS OFFICE AGREES WITH THE
 CONSTRUCTION SERVICES DEPARTMENT
 WITH REGARDS TO 803.4 AND THEIR
 COMMENTS. PLEASE REVISE AS NECESSARY.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-08-11 Cont ID  
Sent By nmccray Date 2003-08-11 Time 11:04 Rev Time 0.00
Received By nmccray Date 2003-08-11 Time 11:03 Sent To  
Notes
2003-08-11 00:00:001) PLEASE REF NFPA 101 LIFE SAFETY CODE
 2000 EDITION CHAPTER 39.
  
 2) INTERIOR FINISHES FOR WALL AND
 CEILING SHALL COMPLY WITH CH 39.3.3.2.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-03-16 Cont ID  
Sent By csiegber Date 2004-03-16 Time 16:28 Rev Time 0.00
Received By csiegber Date 2004-03-16 Time 16:28 Sent To M
Notes
2004-03-16 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-12-02 Cont ID  
Sent By csiegber Date 2003-12-02 Time 12:06 Rev Time 0.00
Received By csiegber Date 2003-12-02 Time 12:06 Sent To  
Notes
2003-12-02 00:00:00TO COMM BD#45

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-29 Cont ID  
Sent By csiegber Date 2003-09-29 Time 09:59 Rev Time 0.00
Received By csiegber Date 2003-09-29 Time 09:59 Sent To  
Notes
2003-09-29 00:00:00TO COMM BD #35

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-18 Cont ID  
Sent By alange Date 2003-08-18 Time 13:49 Rev Time 0.00
Received By alange Date 2003-08-18 Time 13:47 Sent To  
Notes
2003-08-18 00:00:00TO COMM BOARD #31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-11 Cont ID  
Sent By shernand Date 2003-07-11 Time 11:44 Rev Time 0.00
Received By shernand Date 2003-07-11 Time 11:44 Sent To  
Notes
2003-07-11 00:00:00COMM BOARD #57

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-03-31 Cont ID  
Sent By pkrauss Date 2004-03-31 Time 14:31 Rev Time 0.30
Received By pkrauss Date 2004-03-31 Time 14:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-26 Cont ID  
Sent By csiegber Date 2004-03-16 Time 16:28 Rev Time 0.40
Received By pkrauss Date 2003-07-26 Time 11:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-12-16 Cont ID  
Sent By kstevens Date 2003-12-16 Time 17:43 Rev Time 0.50
Received By kstevens Date 2003-12-16 Time 17:43 Sent To  
Notes
2003-12-16 00:00:00REVISION OK - CHANGED WOMEN'S TOILET RM.
 CHANGED LOCATION OF DRINKING FOUNTAINS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-09-19 Cont ID  
Sent By kstevens Date 2003-09-19 Time 16:02 Rev Time 1.25
Received By kstevens Date 2003-09-19 Time 16:02 Sent To  
Notes
2003-09-19 00:00:00PASSED/PROVISO
  
 WATER COOLER MANUF. INFORMATION REQUIRED
 AT TIME OF PLUMBING FINAL. WATER COOLER
 SHALL BE ARI-1010 COMPLIANT.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-22 Cont ID  
Sent By kstevens Date 2003-07-22 Time 12:46 Rev Time 1.75
Received By kstevens Date 2003-07-22 Time 12:45 Sent To  
Notes
2003-07-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FBC-2001 AMENDMENTS CHAPTER 1
 FLORIDA STATUTES
  
 1) SHT AD-1 ALL PLUMBING PIPES THAT ARE
 CUT & CAPPED SHALL BE INSPECTED PRIOR TO
 COVERING.
 2) SHT P-1 PLUMBING NOTES #9, PER SEC
 90-125(B)(5) CITY CODE WPB, CONDENSATE
 SHALL NOT DRAIN INTO SANITARY SYSTEM.
 CONDENSATE SHALL DRAIN SEPARATELY OUT OF
 THE BLDG INTO STORM DRAIN, CATCH BASIN,
 OR A DRYWELL. A RELIEF VENT IS REQUIRED
 AS THE CONDENSATE EXITS THE BLDG. SUBMIT
 A DETAIL AND A RISER DIAGRAM FOR COND.
 3) SHT P-1 WATER RISER DIAGRAM, FULL
 OPEN VALVES SHALL BE INSTALLED ON THE
 TOP OF EVERY WATER DOWN-FEED PIPE PER
 SEC 606.1(4).
 4) SHT P-1 WATER RISER DIAGRAM, SHOWS A
 1/2" LINE TO WD-1. THIS IS NOT FOUND ON
 THE PLUMBING FIXTURE SCHEDULE. PLEASE
 CLAIRFY.
 5) SHT P-2 PLUMBING FIXTURE SCHEDULE IN-
 DICATES A WATER FILTER. FILTER SHALL BE
 NSF APPROVED. MANUF. INFORMATION REQD.
 SECTION 303.4 - ALSO SHOWN ON DETAIL
 A10 SHT P-3.
 6) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND ENG. NUMBER ON
 EACH SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, THE
 NAME, ADDRESS, AND ENGINEERING BUSINESS
 NUMBER SHALL BE LEGIBLY INDICATED ON
 EACH SHEET. NO ENGINEER/BUSINESS NUMBER
 SHOWN ON TITLE BLOCK. 61G15-23.002(2)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692