| Plan Review Stops For Permit 03070731 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-01-06 |
Time |
09:48 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2004-01-06 |
Time |
09:48 |
Sent To |
PC |
|
| Notes |
| 2004-01-06 00:00:00 | BUILDING REVISION # 4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-10-10 |
Time |
12:01 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2003-10-10 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-08-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-29 |
Time |
10:00 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-08-28 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2003-08-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03070731 | | | ADD: 1325 N CONGRESS AVE | | | CONT: INNOVATIVE CONTRACTORS | | | TEL: (954)781-4167 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT# 3 FROM 1ST REVIEW: | | | SHEET A-9 INDICATES THE USE OFA FOAM | | | SOFFIT, FL BLDG CODE 803.4 FOAM PLASTIC | | | SHALL NOT BE USED AS AN INTERIOR TRIM. | | | YOUR RESPONCE BACK, THAT IT MEETS THE | | | EXCEPTION CRITERIA. | | | | | | THE EXCEPTION CRITERIA THAT YOU NOTE | | | MUST MEET ALL OF THE (4) EXCEPTIONS. | | | THE FIRST BEING 20 LBS/CU FT. THEPRO- | | | DUCT TESTING REPORT SUBMITTED INDICATES | | | THE DENSITY OF 1.25 LBS/PCF. | | | | | | THE 2ND IS MAXIMUM THICKNESS OF 1/2" | | | TRIM, MAXIMUM WIDTH OF 4". | | | THE DETAIL INDICATES THE WIDTH OF 4". | | | | | | THE TRIM MEETS THE THIRD REQUIREMENT OF | | | 10% OF THEWALL OR CEILING AREA. | | | | | | THE FLAMESPREAD RATING OF 75 NOT TO BE | | | EXCEEDED. IT APPEARS TO MEET THIS | | | REQUIREMENT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-08-08 |
Time |
14:51 |
Rev Time |
2.25 |
| Received By |
jwitmer |
Date |
2003-08-08 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2003-08-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03070731 | | | ADD: 1325 N CONGRESS AVE | | | CONT: INNOVATIVE CONTRACTORS INC | | | TEL: (954)781-4167 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | IS THIS SPACE FIRE SPRINKLERED? | | | | | | 2) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY. SEE TABLE 803.3. | | | | | | 3) SHEET A-9 INDICATES THE USE OF FOAM | | | SOFFIT, FL BLDG CODE 803.4, FOAM | | | PLASTICS SHALL NOT BE USED AS AN INTER- | | | IOR FINISH. | | | | | | 4) SHEET A-5.1 THE HALLWAY DOOR LEADING | | | TO THE RESTROOMS, MAY NOT HAVE 18" CLEAR | | | ON THE LATCH SIDE, CLEAR FLOOR SPACE, | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-17 |
Time |
15:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-12-17 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-27 |
Time |
06:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-08-27 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | NOTE *** | | | | | | ENGINEER ONLY PLACE LICENSE # ON REVISED | | | SHEET. | | | WROTE # HAND WRITTEN ON OTHER E-SHEETS | | | ONLY. | | | PLEASE NOTE THIS IS REQ'D ON ALL SHEETS | | | INCLUDINGBLDG, MECH, PLUMB, UNDER | | | FS471,481 AND FAC 61G15-23.002/61G1-16. | | | 004. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-21 |
Time |
11:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-21 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2003-07-21 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE THE ATTACHED COPY OF | | | FAC; 61G15-23.002 FOR REQ'D MISSING | | | INFORMATION ON TITLE BLOCK FOR ENGINEER | | | OF RECORD. FS 471 | | | | | | 2)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%.215-3,230-42 ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-02 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-02 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-02 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-02 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | 1) THIS OFFICE AGREES WITH THE | | | CONSTRUCTION SERVICES DEPARTMENT | | | WITH REGARDS TO 803.4 AND THEIR | | | COMMENTS. PLEASE REVISE AS NECESSARY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-11 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-11 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | 1) PLEASE REF NFPA 101 LIFE SAFETY CODE | | | 2000 EDITION CHAPTER 39. | | | | | | 2) INTERIOR FINISHES FOR WALL AND | | | CEILING SHALL COMPLY WITH CH 39.3.3.2. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-16 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-16 |
Time |
16:28 |
Sent To |
M |
|
| Notes |
| 2004-03-16 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-02 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-02 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2003-12-02 00:00:00 | TO COMM BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-29 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-29 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | TO COMM BD #35 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-18 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-18 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | TO COMM BOARD #31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-11 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-11 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2003-07-11 00:00:00 | COMM BOARD #57 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-31 |
Time |
14:31 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-03-31 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-16 |
Time |
16:28 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-07-26 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-16 |
Time |
17:43 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-12-16 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2003-12-16 00:00:00 | REVISION OK - CHANGED WOMEN'S TOILET RM. | | | CHANGED LOCATION OF DRINKING FOUNTAINS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-19 |
Time |
16:02 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2003-09-19 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2003-09-19 00:00:00 | PASSED/PROVISO | | | | | | WATER COOLER MANUF. INFORMATION REQUIRED | | | AT TIME OF PLUMBING FINAL. WATER COOLER | | | SHALL BE ARI-1010 COMPLIANT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-07-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-22 |
Time |
12:46 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2003-07-22 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2003-07-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FBC-2001 AMENDMENTS CHAPTER 1 | | | FLORIDA STATUTES | | | | | | 1) SHT AD-1 ALL PLUMBING PIPES THAT ARE | | | CUT & CAPPED SHALL BE INSPECTED PRIOR TO | | | COVERING. | | | 2) SHT P-1 PLUMBING NOTES #9, PER SEC | | | 90-125(B)(5) CITY CODE WPB, CONDENSATE | | | SHALL NOT DRAIN INTO SANITARY SYSTEM. | | | CONDENSATE SHALL DRAIN SEPARATELY OUT OF | | | THE BLDG INTO STORM DRAIN, CATCH BASIN, | | | OR A DRYWELL. A RELIEF VENT IS REQUIRED | | | AS THE CONDENSATE EXITS THE BLDG. SUBMIT | | | A DETAIL AND A RISER DIAGRAM FOR COND. | | | 3) SHT P-1 WATER RISER DIAGRAM, FULL | | | OPEN VALVES SHALL BE INSTALLED ON THE | | | TOP OF EVERY WATER DOWN-FEED PIPE PER | | | SEC 606.1(4). | | | 4) SHT P-1 WATER RISER DIAGRAM, SHOWS A | | | 1/2" LINE TO WD-1. THIS IS NOT FOUND ON | | | THE PLUMBING FIXTURE SCHEDULE. PLEASE | | | CLAIRFY. | | | 5) SHT P-2 PLUMBING FIXTURE SCHEDULE IN- | | | DICATES A WATER FILTER. FILTER SHALL BE | | | NSF APPROVED. MANUF. INFORMATION REQD. | | | SECTION 303.4 - ALSO SHOWN ON DETAIL | | | A10 SHT P-3. | | | 6) ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS, AND ENG. NUMBER ON | | | EACH SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, THE | | | NAME, ADDRESS, AND ENGINEERING BUSINESS | | | NUMBER SHALL BE LEGIBLY INDICATED ON | | | EACH SHEET. NO ENGINEER/BUSINESS NUMBER | | | SHOWN ON TITLE BLOCK. 61G15-23.002(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|