| Plan Review Stops For Permit 03070677 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-09-05 |
Time |
15:51 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2003-08-21 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | ***********BUILDING FAILED********** | | | | | | 1. IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY AND BOTH PLANS STAMPED.A | | | COPY OF THE PAID RECEIPT MUST BE | | | SUBMITTED WITH THE STAMPED PLANS BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 2. A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3. PRODUCT APPROVALS FOR THE GLASS BLOCK | | | MUST BE HIGHLIGHTED TO SHOW WHICH BLOCK | | | IS BEING USED ON THE 1ST & 2ND FLOOR | | | AND MUSTCOMPLY WITH HAZARDOUS | | | | | | 4. THE KEY PLAN FOR THE STORM PANELS | | | DOES NOT MATCH THE ELEVATIONSSHOWN | | | ON THE PLANS.CORRECT & RESUBMIT. | | | HIGHLIGHT THE FASTENER METHOD ON THE | | | PRODUCT APPROVAL. | | | | | | 5. NOTE WIND PRESSURES ON A1: CHECK FOR | | | ACCURACY. | | | | | | | | | ANY QUESTIONS PLEASE CALL | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
14:32 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2004-08-03 00:00:00 | REDLINED 2002 NEC 210.12B |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
08:29 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-12 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-07 |
Time |
16:50 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-13 |
Time |
09:08 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-29 |
Time |
08:29 |
Sent To |
E |
|
| Notes |
| 2004-07-29 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-07 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-07 |
Time |
16:50 |
Sent To |
E |
|
| Notes |
| 2003-11-07 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-05 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-09-05 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-09-05 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
| 2003-09-05 00:00:00 | TO LSMITH DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-05 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-05 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-05 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-01 |
Time |
10:36 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-13 |
Time |
09:09 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-08-18 |
Time |
07:14 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-18 |
Time |
07:14 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2003-08-20 |
Time |
17:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-01 |
Time |
10:36 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|