| Plan Review Stops For Permit 03070671 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-15 |
Time |
18:03 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-09-15 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2003-09-15 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THREE DIFFERENT PRODUCT APPROVALS | | | WERE SUBMITTED.ONLY ONE DOOR IS BEING | | | INSTALLED.SUBMIT TWO COPIES OF THE | | | PRODUCT APPROVAL FOR THE DOOR BEING | | | INSTALLED.ALSO, THE DRAWING SHEETS | | | DO NOT MATCH THE COVER SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-03 |
Time |
15:01 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-09-03 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2003-09-03 00:00:00 | PROVISO - SUBMIT DOOR PRODUCT APPROVALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-02 |
Time |
16:00 |
Rev Time |
1.00 |
| Received By |
sgraham |
Date |
2003-08-19 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2003-08-19 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THIS IS A 27% IMPROVEMENT AND MUST | | | COMPLY WITH FBC3401.7.1.2, 2003 AMEND- | | | MENTS. | | | | | | 2.)THE SIMPSON MTS16 IS A WOOD TO WOOD | | | CONNECTOR, NOT A CONCRETE TO WOOD. | | | | | | 3.)THE REVISED CONNECTION MTSM16 DOES | | | NOT SPECIFY THE CORRECT ATTACHMENT | | | SCHEDULE.SEE THE SIMPSON 2003 | | | CATALOG FOR CORRECT ATTACHMENTS. | | | | | | 4.)HOW WILL THE NEW FOUNDATION TIE | | | INTO THE EXISTING?TIE BEAM? | | | | | | 5.)THE DOOR INFORMATION PROVIDED IS | | | FOR A DOOR W/SIDELITE.REVISE THE PLAN. | | | | | | 6.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | | | | 7.)ONLY ONE COPY OF THE FOLLOWING | | | ITEMS WERE SUBMITTED (TWO REQUIRED): | | | ENERGY CALC | | | SURVEY | | | ROOF PRODUCT APPROVAL (MAY SUBMIT THE | | | FIRST 5 PAGES, NOT ALL 55 PAGES) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-19 |
Time |
09:11 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-07-28 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2003-07-28 00:00:00 | ******CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)TWO COPIES OF ALL PERMITTING | | | DOCUMENTS MUST BE SUBMITTED.ONLY | | | ONE SUBMITTED (SURVEY, PRODUCT | | | APPROVALS). | | | | | | 2.)PROVIDE AREA CALCULATIONS ON THE | | | PLAN - EXISTING AND PROPOSED. | | | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4.)ENERGY CALCS REQUIRED FBC13-101.2. | | | | | | 5.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE ORIGINAL RECEIPT | | | ATTACHED TO THE APPLICATION.233-5025 | | | | | | 6.)ADDITIONAL FEES DUE (VALUE | | | ADJUSTMENT), $238.97. | | | | | | 7.)PROVIDE DESIGN INFORMATION ON THE | | | PLAN, FBC1606.1.7. | | | | | | 8.)SPECIFY DESIGN UPLIFT ON THE PLAN. | | | | | | 9.)1 1/2" WATERSTOP REQUIRED, CITY OF | | | WEST PALM BEACH AMENDMENTS TO THE FBC, | | | 2111.1.9. | | | | | | 10.) THE FOOTER IS TO BE A MINIMUM OF | | | 12" BELOW GRADE, 1804.1.3. | | | | | | 11.) SUBMIT TWO LEGIBLE COPIES OF | | | THE FOLLOWING PRODUCT APPROVALS: | | | SINGLE HUNG WINDOW | | | IMPACT PROTECTION PER FBC1606.1.4 | | | EXTERIOR DOOR | | | | | | 12.) THE SIMPSON CATALOG SPECIFIES THE | | | LTS AS A CONNECTOR BETWEEN TWO WOOD | | | MEMBERS.YOU HAVE IT TAPCONNED INTO | | | A CONCRETE BEAM.CLARIFY. | | | | | | 13.)FIRESTOP REQUIRED FBC705.3. | | | | | | 14.)PROVIDE A SOILS INVESTIGATION | | | REPORT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
10:12 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-07-16 |
Time |
11:50 |
Sent To |
P |
|
| Notes |
| 2003-07-16 00:00:00 | PLANS REDLINED | | | 210-8 | | | 210-12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-09-02 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-09-02 |
Time |
16:00 |
Sent To |
B |
|
| Notes |
| 2003-09-02 00:00:00 | TO ST DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-19 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-19 |
Time |
09:11 |
Sent To |
B |
|
| Notes |
| 2003-08-19 00:00:00 | TO ST DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-15 |
Time |
10:12 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-17 |
Time |
14:59 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-07-17 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | | | | PLEASE PROVIDE A COMPLETED FORM 600C. | | | | | | INDICATE IF EQUIPMENT IS NEW OR EXISTING | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-16 |
Time |
11:51 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-07-17 |
Time |
14:59 |
Sent To |
M |
|
| Notes |
| 2003-07-17 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-14 |
Time |
16:26 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|