Plan Review Details - Permit 03070362
Plan Review Stops For Permit 03070362
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-18 Cont ID  
Sent By lsmith Date 2003-08-18 Time 14:24 Rev Time 0.50
Received By lsmith Date 2003-08-18 Time 14:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-23 Cont ID  
Sent By kstevens Date 2003-08-16 Time 11:54 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2003-07-23 00:00:00*******FAILED*********
  
 1. PLANS TO SHOW METHOD OF PROTECTING
 THE POOL FROM ANY OPENINGS FROMO HOUSE
 TO POOL AREA. (IE: ALARMS, BABY BARRIER,
 POOL COVER)AS SHOWNN IN FBC 2001 CHAPTER
 424.2.17.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EQUIPMENT
 805-6713

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-23 Cont ID  
Sent By kstevens Date 2003-07-17 Time 16:53 Rev Time 0.33
Received By btrobaug Date 2003-07-23 Time 07:50 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-13 Cont ID  
Sent By alange Date 2003-08-13 Time 13:30 Rev Time 0.00
Received By alange Date 2003-08-13 Time 13:30 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-11 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:50 Rev Time 0.00
Received By shernand Date 2003-07-11 Time 16:50 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 12:37 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 12:37 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-08-18 Cont ID  
Sent By kstevens Date 2003-08-18 Time 09:53 Rev Time 0.50
Received By kstevens Date 2003-08-18 Time 09:52 Sent To  
Notes
2003-08-18 00:00:00PER CONTRACTOR - POOL HEATER STUB-UPS
 ONLY - HEATER TO BE FUTURE

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-08-16 Cont ID  
Sent By kstevens Date 2003-08-16 Time 11:54 Rev Time 0.50
Received By kstevens Date 2003-08-16 Time 11:53 Sent To B
Notes
2003-08-16 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA STATUTES
  
 A) FOLLOWING COMMENTS NOT ADDRESSED:
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 (NEW COMMENT)
 SEE ATTACHED SHEET CONCERNING THE TITLE
 BLOCK FOR ENGINEERS. LICENSE NUMBER NOT
 SHOWN ON SHEETS SUBMITTED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-17 Cont ID  
Sent By alange Date 2003-08-13 Time 13:30 Rev Time 0.75
Received By kstevens Date 2003-07-17 Time 16:53 Sent To E
Notes
2003-07-17 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 2) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 3) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 5) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 6) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 7) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 8) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.(ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 2 Status P Date 2003-07-14 Cont ID  
Sent By mmclean Date 2003-07-14 Time 15:03 Rev Time 1.00
Received By mmclean Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-07-10 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:50 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
2003-07-10 00:00:007/10/03 DENIED, NEED TO SHOW SET-BACKS
 ON SURVEY CALL CONTR FOR PICK UP "C" MM